期刊文献+

顶空气相色谱法测定胶囊壳中环氧乙烷残留量 被引量:2

Determination of Ethylene Oxide Residue in Capsules by Headspace Capillary Gas Chromatography
在线阅读 下载PDF
导出
摘要 建立了胶囊壳中环氧乙烷残留量的顶空气相色谱分析方法,考察了色谱柱、顶空平衡温度、平衡时间等对环氧乙烷残留量测定的影响。结果表明,利用DB-WAX毛细管柱在顶空平衡温度为50℃、平衡时间为15 min时,可以获得好的定量结果。环氧乙烷的线性范围为0.2~5.0 mg/L(r=0.999 9),回收率为94.22%~103.40%,精密度(RSD)为0.48%~3.92%,检出限(LOD)为0.3 mg/kg。该方法准确、灵敏、简便,对胶囊壳中环氧乙烷残留量的检测提供了技术支持。 A method of headspace gas chromatography for the determination of ethylene oxide residue in capsules was developed.The effects of equilibrium temperature,equilibrium time on the determination of ethylene residue oxide were investigated. The good results were obtained in the equilibrium temperature of 50 ℃ for 15 min with DB-WAX capillary column. Ethylene oxide showed good linearity over the range of 0. 2 ~ 5. 0 mg / L( r = 0. 999 9). The recoveries were between 94. 22% and 103. 40% with relative standard deviations( RSD) of 0. 48% ~ 3. 92%. The limit of detection was 0. 3 mg / kg. The proposed method was successfully applied to analyze ethylene oxide residue in the real sample. The method is rapid,sensitive and accurate to determinate ethylene oxide residue in capsules.
出处 《化学试剂》 CAS 北大核心 2015年第11期1018-1020,共3页 Chemical Reagents
基金 重庆市科委食品农产品科研专项项目(cstc-2013yykf B0165)
关键词 顶空气相色谱法 胶囊 环氧乙烷 Headspace capillary gas chromatography capsules ethylene oxide
作者简介 高小丽(1979-),女,四川乐山人,硕士,讲师,研究方向为学生管理。 通讯作者:曹淑瑞,E—mail:caoshurui@yeah.net。
  • 相关文献

参考文献10

二级参考文献63

共引文献59

同被引文献11

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部