期刊文献+

管道地铁杂散电流干扰腐蚀风险评估与防护措施 被引量:7

Corrosin Risk Evaluation and Protection Measures of Pipeline Interfered by Metro Stray Current
在线阅读 下载PDF
导出
摘要 某输气管道受地铁杂散电流干扰影响,阴极保护电位波动大,且长时间正于-850 mV(相对于CSE),阴极保护系统受干扰严重,管道受阴极保护效果未知。为了解管道真实阴极保护状况,对沿线管道土壤电阻率进行测试,对管道通断电电位进行了24 h监测,确定了管道最小阴极保护电位,并评估了管道阴极保护状况。基于管道干扰风险分析结果,调整了阴极保护站输出参数,并开展了现场馈电试验。通过连续的馈电测试,获得了较优的干扰防护措施。 A gas transmission pipeline was affected by the subway interference.The pipeline cathodic protection potential fluctuated greatly and was positive than-850 mV(compared to CSE)for a long time.As a result,the cathodic protection system was seriously interfered,and the effect of cathodic protection on the pipeline was unknown.In order to know the real cathodic protection status of the pipeline,the soil resistivity was tested,and the pipeline potential were monitored for 24 hours,so as to determine the minimum cathodic protection potential value and evaluate the cathodic protection status of the pipeline.Based on the corrosion risk analysis results,the cathodic protection station running parameters were adjusted and continuous feeding tests were carried out.Through continuous field test,an optimized interference protection method was obtained.
作者 张梦梦 徐友鹏 胡贵斌 冯德佳 吴广春 杜雪麟 江远超 ZHANG Mengmeng;XU Youpeng;HU Guibin;FENG Dejia;WU Guangchun;DU Xuelin;JIANG Yuanchao(Safetech Research Institute,Beijing 102200,China;National Pipeline Network Group Guangdong Operation and Maintenance Center Guangdong Branch,Guangzhou 510000,China;West-East Gas Transmission Branch,National Petroleum and Gas Pipeline Network Group Co.,Ltd.,Xiamen 361000,China)
出处 《腐蚀与防护》 CAS CSCD 北大核心 2023年第6期82-89,共8页 Corrosion & Protection
关键词 管道 地铁杂散电流 腐蚀风险 馈电测试 pipeline subway stray current corrosion risk feeding test
作者简介 通信作者:吴广春(1986-),中级工程师,硕士,主要从事腐蚀与防护研究工作,13686425900,584846686@qq.com。
  • 相关文献

参考文献12

二级参考文献73

共引文献114

同被引文献65

引证文献7

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部