摘要
本文介绍了国内动态直流杂散电流和交流杂散电流的评价标准,分析了交流干扰评价中计算交流电流密度和实测交流电流密度的适用性。通过对遭受交直流混合干扰的某段管道开展现场测试及评价,结果表明:动态直流杂散电流干扰采用AS2832.1—2015标准进行评价可操作性比较强,对于交直流混合干扰的情况,建议以实测的交流电流密度按照SY/T0087.6—2021中综合评价指标进行评价。
This paper introduces the evaluation criteria of dynamic DC stray current and AC stray current at home,analyzes the applicability of calculating AC current density and measured AC current density,and carries out field tests on a pipeline subjected to AC-DC mixed interference.The results show that it is feasible to evaluate dynamic DC stray current interference with AS 2832.1—2015 standard.For AC-DC mixed interference,it is recommended to evaluate the measured AC current density according to SY/T 0087.6—2021 comprehensive evaluation index.
作者
阎雪冬
郭艳伟
凌沛文
陈玉宝
杨树斌
yan Xuedong;Guo yanwei;Ling Peiwen;Chen yubao;yang Shubin(Guangdong Institute of Special Equipment Inspection and Research,Foshan 528000)
出处
《中国特种设备安全》
2025年第1期55-58,共4页
China Special Equipment Safety
基金
广东省市场监督管理局科技项目“埋地钢质管道杂散电流腐蚀规律研究及评价”(2023ZT02)。
作者简介
阎雪冬(1975-),男,本科,工程师,从事承压类特种设备检验检测评价工作;通讯作者:郭艳伟,E-mail:xitu081@126.com。