摘要
储能系统不合理操作会有引发火灾的可能性,针对这一问题,提出孤网运行状态下储能系统容量配置研究。首先,通过建立容量配置模型、构建容量目标函数并建立二者之间的映射关系,研究孤网运行状态下储能系统容量配置方法。然后,通过对比实验证明孤网运行状态下储能系统容量可以达到最优配置效果,具有更强的抗干扰性。
The improper operation of the energy storage system may cause a fire.In view of this problem,a study on the capacity allocation of the energy storage system under the isolated grid operation state is proposed.First,by establishing a capacity allocation model,a capacity objective function,and a mapping relationship between the two,the capacity allocation method of an energy storage system under isolated grid operating conditions is studied.Then,through comparative experiments,it is proved that the capacity of the energy storage system can achieve the optimal allocation effect under the isolated grid operation state,and has stronger anti-interference performance.
作者
王卫国
朱俊飞
丁朝辉
WANG Wei-guo;ZHU Jun-fei;DING Chao-hui(Zhenjiang Electric Power Design Institute Co.,Ltd.,Zhenjiang 212000,China;State Grid Zhenjiang Power Supply Company,Zhenjiang 212000,China)
出处
《通信电源技术》
2020年第3期17-18,共2页
Telecom Power Technology
关键词
孤网运行
储能系统
容量配置
isolated network operation
energy storage system
capacity allocation
作者简介
王卫国(1970-),男,江苏泰州人,硕士,高级工程师,主要研究方向为电力系统运行与规划。