摘要
姚孟发电有限责任公司#1锅炉甲侧吸风机运行中出现失速现象,通过数据和理论分析认为,#1锅炉甲侧吸风机失速原因为空气预热器低温腐蚀积灰引起,采取了有效措施后,失速现象消失。
In operation of side A induced draft fan of boiler No.1 in Yaomeng Power Company Limited,the stall phenomenon occurred.According to the operation data and theory analysis,it was considered that the stall reason of the said induced draft fan is low temperature corrosion caused by ash deposition of the preheater.After effective measures were adopted,the stall phenomenon was eliminated.
出处
《华电技术》
CAS
2012年第5期48-51,79,共4页
HUADIAN TECHNOLOGY
关键词
吸风机
失速
低温腐蚀
积灰
应对措施
induced draft fan
stall
low temperature corrosion
ash deposition
responsive measure
作者简介
曹永齐(1976-),男,河南漯河人,工程师,从事生产技术管理方面的工作。
姚中栋(1972-),男,河南南阳人,工程师,从事生产管理方面的工作(E-mail:yzdong1226@163.com)。