摘要
纺织品在加工的过程中会引起多种有害元素的污染,为了监控纺织品的质量,建立了微波辅助稀硝酸萃取结合电感耦合等离子体发射光谱同时测定纺织品中砷、锑、铅、镉、铬、钴、铜、镍、汞等九种有害元素的检测新方法。通过萃取剂的筛选和萃取条件的优化,最终确定了用5%的硝酸30mL作为萃取剂,萃取时间为5min,萃取温度为120℃,仪器功率为400W作为微波辅助萃取条件。并用电感耦合等离子体发射光谱对萃取出的九种有害元素总量进行检测。结果显示:本方法的检出限在2.25~112.5μg.kg-1之间,对加标样品的萃取率为73.6%~105%,相对标准偏差(RSD,n=3)为0.2%~1.7%。本方法已成功用于棉布、毛料、涤纶、腈纶四种纺织品样品的检测。
Textiles are easily contaminated by heavy metals in the course of processing.I n order to monitor the quality of textiles,a new method was developed for si multaneous determination of arsenic,antimony,lead,cadmium,chromium,cobalt, copper,nickel and mercury in textiles by inductively coupled plasma optical emi ssion spectrometry(ICP-OES) after microwave-assisted dilute nitric acid extra ction.After optimizing extraction conditions,we ultimately selected 5% nitri c acid as extractant and 5 min as extraction time with the extraction temperatur e of 120 ℃ and instrument power of 400W in the microwave-assisted extraction procedure.Nine hazardous elements were detected sequentially by ICP-OES.Th e results showed that the detection limits were 0.3~15 μg·L-1 and the recoveries 73.6%~105% with the RSDs(n=3) of 0.1%~3%.The proposed meth od was successfully used to determine nine elements in cotton,wool,terylene an d acrylic.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
2012年第1期239-243,共5页
Spectroscopy and Spectral Analysis
基金
国家自然科学基金项目(10505023)
国家质检总局基金项目(2009IK108)资助
作者简介
陈飞,1983年生,南华大学与中国科学院高能物理研究所联合培养硕士研究生Email:chenfei@ihep.ac.cn
通讯联系人e-mail:jdeng_usc@163.comxudd@ihep.ac.cn