期刊文献+

多路红外激光脉冲波形测量技术 被引量:8

Pulse-shape measurement technology for multi-beams infrared laser
在线阅读 下载PDF
导出
摘要 介绍了一种用于高功率大型激光装置的多路红外激光脉冲波形测量原理和系统构成。整个测量系统由取样与光纤耦合单元、光纤传输单元、光纤合束与光电转换单元、数据采集单元构成,针对多路合束导致测量系统存在取样稳定性难题采用望远缩束、成像相结合的光纤耦合方法解决了光束的角漂问题,并对脉冲测试的影响因素进行了系统评价。实验结果表明,利用该系统测得的纳秒脉冲展宽量小于150 ps,系统稳定耦合角度变化范围大于±1 mrad。该技术降低了系统的复杂性,降低了测量成本,有效地解决了时间脉冲波形测试中稳定耦合问题,保证了测量系统的可靠性。 The configuration and principle of the temporal profile measurement system were introduced,which was used for multi-beam infrared laser of the large high-power facility.The system was composed of power sampling unit,fiber transmission unit,multiplexing coupler unit,photoelectric conversion unit and data acquisition unit.For the systemic problem of sample stability in the multiplexing measurement system,the lens imaging method was adopted in sampling of optical fiber in order to solve the problem of the great drift of beams.The influence of the temporal profile measurement was systematically evaluated.The experiment results show that with the nanosecond-level pulse,the pulse broadening is controlled within 150 ps,and the range of coupling angle is bigger than ±1′.This technology has solved the stable coupling problem effectively,and guarantees the measurement system reliability.
出处 《红外与激光工程》 EI CSCD 北大核心 2011年第6期1129-1132,共4页 Infrared and Laser Engineering
基金 中国工程物理研究院激光聚变研究中心和等离子体物理国家级重点实验室创新基金
关键词 光纤光学 脉冲波形 高功率激光 fiber optics temporal profile high power laser
作者简介 卢宗贵(1978-),男,硕士,主要从事高功率激光参数诊断研究。Email:haitianle2007@sina.com.cn
  • 相关文献

参考文献10

二级参考文献38

共引文献12

同被引文献52

  • 1周萍,赵玮,吴长江.大型光学元件中的横向受激布里渊散射[J].光学技术,2006,32(z1):441-444. 被引量:1
  • 2赵军普 胡东霞 周维等.高功率固体激光近场强度功率谱密度特性分析.光学学报,2008,28(1):118-122.
  • 3彭志涛 孙志红 刘华等.基于光栅取样的靶场激光参数诊断技术研究.中国激光,2009,36(1):280-282.
  • 4康娟 冯爱明 徐时清等.相机用超高动态CCD特性分析及应用.光学学报,2008,28(2):262-265.
  • 5夏彦文,卢宗贵,唐军,等.高功率激光脉冲光纤耦合取样技术研究[J].计量学报,2009,30(6A):167-169.
  • 6Leclerc P, Allouche V. Temporal response diagnostic for the laser MegaJoule[C]//SPIE, 1999, 3492: 843-850.
  • 7Thomas S, Boyd B, Davis D T, et al. Temporal multiplexing for economical measurement of power versus time on NIF [C]//SPIE, 1997, 3047: 700-706.
  • 8Zhang Xiaomin, Zheng Wanguo, Wei Xiaofeng et al.. Preliminary experimental results of Shenguang Ⅲ technical integration experiment line [C]. SPIE, 2005, 5627: 6-12.
  • 9Donaldson W R, Boni R, Keck R L, et al.. UV power balance on the OMEGAlaser[C]. SPIE, 1999, 3609.- 121-127.
  • 10Lerche R A. Timing between streak cameras with a precision of 10 psych. SPIE, 1991, 1346:376- 383.