期刊文献+

分子印迹技术应用于血清中地高辛的快速检测 被引量:4

Rapid detection of digoxin in serum samples by molecular imprinted biosensor
在线阅读 下载PDF
导出
摘要 应用分子印迹的方法制备对地高辛有特异性吸附性能的印迹聚合物颗粒,再将颗粒与琼脂糖混合并固定于玻碳电极上制备成地高辛分子印迹聚合膜传感器,传感器可以特异性地结合模板分子地高辛且其电化学信号与模板浓度相关,再用它来检测血清中地高辛的含量。结果表明:分子印迹传感器具有制作简便、成本低、检测快速、特异性高、稳定性好等优点,检测下限为1.28 nmol/L,检测时间为5 min。 The biosensor was prepared by molecular imprinted technique with digoxin-specific adsorption properties.Firstly the imprinted polymer particles were prepared.Then,particles and the agarose were mixed in proportion.The molecular imprinted polymer film sensor for the digoxin was fixed by the mixture on a glassy carbon electrode(GC).The sensor had specific combination of template molecule-digoxin and its electrochemical signals associated with the template concentration.Thus,it could be used to detect digoxin levels in serum.The molecular imprinted biosensor had advantages of simple,low cost,rapid detection,high specificity,and good stability.The detection limit of the biosensor was 1.28 nmol/L and detection time was 5 min.
出处 《生物加工过程》 CAS CSCD 2011年第2期64-67,共4页 Chinese Journal of Bioprocess Engineering
基金 科技部资助项目(2009GJA10047) 天津市科委资助项目(08ZXCXSH053 09ZCZDSF04200)
关键词 分子印迹传感器 地高辛 聚合物 血清 快速检测 molecular imprinted sensor digoxin polymer serum rapid detection
作者简介 李敏(1985-),女,内蒙古包头人,硕士研究生,研究方向:电化学生物传感器; 张娟琨(联系人),教授,博士生导师,E-mail:zhangjk@rust.edu.cn
  • 相关文献

参考文献15

  • 1李优鑫,毛静远,李惠芬.地高辛血药浓度检测方法的分析[J].中国中药杂志,2007,32(4):285-288. 被引量:11
  • 2Ahmed A,Pitt B, Rahimtoola S H,et al. Effects of digoxin at low serum concentrations on mortality and hospitalization in heart failure:a propensity-matched study of the DIG-trial[ J]. lnt J Cardiol, 2008,123 : 138-146.
  • 3Georgiopoulou V V, Kalogeropoulos A P, Giamouzis G, et al. Digoxin therapy does not improve outcomes in patients with advanced heart failure on contemporary medical therapy [ J ]. Circ Heart Fail ,2009,2:90-97.
  • 4Chen I W,Heminger L A. Digoxin and digitoxin [ M]//Pesce A J, Kaplan L A. Methods in Clinical Chemistry. St Louis:C V Mosby Co. , 1987:897-902.
  • 5Fernandez P, Durand J S, Perez-Conde C,et al. Permanently oriented antibody immobilization for digoxin determination with a flow-through fluoroimmunosensor[ J ]. Anal Bioanal Chem, 2003, 375 : 1020-1023.
  • 6Porter W H, Hayer V M, Bush B A. Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay[ J]. Clin Chem,1984,30( 11 ) :1826-1829.
  • 7Yao M,Zhang H, Chong S, et al. A rapid and sensitive LC/MS/ MS assay for quantitative determination of digoxin in rat plasma [J]. Biota Anal ,2003,32 : 1189-1197.
  • 8Delatour T,Gremaud R,Mottier P,et al. Preparation of stable isolopelabeled 2-nitrobenzaldehyde derivatives of four metaboli/es of nitrofuran antibiotics and their comprehensive characterization by UV,MS, and NMR techniques[J]. Food Chem ,2003 ,51:6371-5379.
  • 9Tamayo F G,Titirici M M, Martin-Esteban A,et al. Synthesis and evaluation of new propazine-imprinted polymer formats for use as stationary phases in liquid chromatography [ J ]. Anal China Acta, 2005,542:38-46.
  • 10Zhu X,Yang J,Su Q,et al. Selective solid-phase extraction using molecularly imprinted polymer for the analysis of polar organophosphorus pesticides in water and soil samples [ J ]. J Chromatogr A ,2005,1092 : 161-169.

二级参考文献29

共引文献10

同被引文献65

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部