摘要 阐述了绝缘油中为防止硫化亚铜沉积而添加的钝化剂的性能,介绍了对其样品前处理和高效液相色谱检测方法进行的研究。对上海地区部分已添加及未添加钝化剂的500 kV变压器绝缘油进行钝化剂含量检测,并提出相应的结论。 The performance of the passivator added to prevent the sedimentary of copper sulphide were elaborated.The analysis and study on the sample pretreatment and the high-performance liquid chromatography(HPLC) detection method were described.The passivator contents in the insulating oils of 500 kV transformers with and without the passivator added in Shanghai district were detected and the corresponding conclusions were proposed.
出处 《华东电力》 北大核心 2010年第12期1876-1878,共3页 East China Electric Power
关键词 变压器绝缘油 钝化剂 高效液相法色谱法 insulating oil of transformer passivator high performance liquid chromatography(HPLC) method
作者简介 朱向群(1965-),女,高级工程师,从事电网化学试验工作。
  • 相关文献

参考文献2

共引文献35

同被引文献43

  • 1Sundara R J, Naidu C J, Dwarakanath K. Influence of Metal Passivator on the Corrosion of Copper Conductors due to Sulphcr in Oil[C]//International Symposium on Electrical Insulating Matcrials,IEEE,2008:487-490.
  • 2Faheem A K, Sundara R J, Ansari M Z A, ct al. An Experimental Study on the Effects of DBDS in Transformer Oil of Power Transformers[C]//2012 International Conference on Advances in Power Conversion and Energy Technologies,IEEE,2012:1-4.
  • 3Schaut A, Autru S, Rop A D, et al. Effects of Irgamet 30 as Additive in Transformer Oil[J]//IEEE Transactions on Dielectrics and Electrical Insulation,2012,19(l):175-180.
  • 4Wiklund P, Levin M, Pahlavanpour B. Copper Dissolution and Metal Passivators in Insulating Oil[J]. IEEE Electrical Insulation Magazine,2007,23(4):7-14.
  • 5Kawarai H, Fujita Y, Tanimura J, et al. Role of Dissolved Copper and Oxygen on Copper Sulfide Generation in Insu- lating Oil[J]. IEEE Transactions on Dielectrics and Electri- cal Insulation,2009,16(5): 1430-1435.
  • 6Malna R, Tumiatt V, Scatiggio F, et al. Transformers Sur- veillance Following Corrosive Sulfur Remedial Procedures [J]. IEEE Transactions on Power Delivery,2011,26(4):2391- 2397.
  • 7Maina R, Tumiatti V, Pompili M, et al. Corrosive Sulfur Ef- fects in Transformer Oils and Remedial Procedures[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2009,16 (6):1655-1663.
  • 8Martins M A G, Gomes A R. Experimental Study of the Role Played by Dibenzyl Disulfide on Insulating Oil Corro- sivity-Effect of Passivator Irgamet 39[J]. IEEE Electrical In- sulation Magazine,2010,26(4):27-32.
  • 9IEC 62535-2008, Insulating Liquids-Test Method for De- tection of Potentially Corrosive Sulphur in Used and Un- used Insulating Oil[S].
  • 10Mitchinson P M, Holt A F, Brown R C D. Investigation into the Formation of Copper Sulphide in Oil Filled Electrical Equipment[C]//2011 IEEE International Conference on Dielectric Liquids,2011:1-4.

引证文献3

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部