期刊文献+

Hammering Sound Frequency Analysis to Fix an Acetabular Cup during Total Hip Arthroplasty: Clinical Trials and Biomechanical Studies 被引量:2

Hammering Sound Frequency Analysis to Fix an Acetabular Cup during Total Hip Arthroplasty: Clinical Trials and Biomechanical Studies
在线阅读 下载PDF
导出
摘要 Failure during total hip arthroplasty may lead to bedridden of the elderly. Since the acetabulum cup fix in an anatomically deep region, failures, such as loosening and fracture, occur three times more frequently compared with failures of the stem fix in the femur. We investigated the possibility of evaluating whether fixation was acquired by frequency analysis of the hammering sound of implanting a cup into the acetabulum. The subjects were 11 patients (11 joints) who underwent total hip arthroplasty, biomechanical test materials, and orthopedic models. Surgeries and experiments were performed by orthopedists specialized in the hip. A system was constructed with a tablet PC and directional microphone, the peak frequency at which the amplitude reached the maximum was determined, and judgment processing (stable, unstable) of cup fixability was performed in real time. The stable maximum peak frequency observed in the clinical trials was 4.42 ± 4.02 kHz. The mean stable maximum peak frequency in the biomechanical tests was 4.46 ± 1.19 kHz in biomechanical test materials and 4.56 ± 2.02 kHz in orthopaedicmodels. When hammering was continued, the frequency leading to fracture decreased in both biomechanical test materials and orthopaedicmodels. In conclusion, in clinical trials and biomechanical studies, variation of the maximum peak frequency decreased when fixation was acquired and the frequency stabilized. It was suggested that this method can serve as a fixability evaluation method of acetabular cups because analysis can be performed in real time during surgery, for which prevention of intraoperative fracture can be expected. Failure during total hip arthroplasty may lead to bedridden of the elderly. Since the acetabulum cup fix in an anatomically deep region, failures, such as loosening and fracture, occur three times more frequently compared with failures of the stem fix in the femur. We investigated the possibility of evaluating whether fixation was acquired by frequency analysis of the hammering sound of implanting a cup into the acetabulum. The subjects were 11 patients (11 joints) who underwent total hip arthroplasty, biomechanical test materials, and orthopedic models. Surgeries and experiments were performed by orthopedists specialized in the hip. A system was constructed with a tablet PC and directional microphone, the peak frequency at which the amplitude reached the maximum was determined, and judgment processing (stable, unstable) of cup fixability was performed in real time. The stable maximum peak frequency observed in the clinical trials was 4.42 ± 4.02 kHz. The mean stable maximum peak frequency in the biomechanical tests was 4.46 ± 1.19 kHz in biomechanical test materials and 4.56 ± 2.02 kHz in orthopaedicmodels. When hammering was continued, the frequency leading to fracture decreased in both biomechanical test materials and orthopaedicmodels. In conclusion, in clinical trials and biomechanical studies, variation of the maximum peak frequency decreased when fixation was acquired and the frequency stabilized. It was suggested that this method can serve as a fixability evaluation method of acetabular cups because analysis can be performed in real time during surgery, for which prevention of intraoperative fracture can be expected.
作者 Rina Sakai Katsufumi Uchiyama Kensuke Fukushima Naonobu Takahira Kazihiro Yoshida Masanobu Ujihira Rina Sakai;Katsufumi Uchiyama;Kensuke Fukushima;Naonobu Takahira;Kazihiro Yoshida;Masanobu Ujihira(Department of Biomedical Engineering and Technology, School of Allied Health Sciences, Kitasato University, Kanagawa, Japan;Department of Orthopedic Surgery, Kitasato University, Kanagawa, Japan)
出处 《Journal of Biomedical Science and Engineering》 2021年第1期14-20,共7页 生物医学工程(英文)
关键词 Total Hip Arthroplasty Hammering Sound Frequency Analysis Intraoperative Fracture LOOSENING Total Hip Arthroplasty Hammering Sound Frequency Analysis Intraoperative Fracture Loosening
  • 相关文献

参考文献2

共引文献5

同被引文献2

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部