期刊文献+

Prediction of Intraoperative Fracture by Hammering Sound Frequency Analysis and Stress Estimation during Total Hip Arthroplasty 被引量:4

Prediction of Intraoperative Fracture by Hammering Sound Frequency Analysis and Stress Estimation during Total Hip Arthroplasty
在线阅读 下载PDF
导出
摘要 When a stem is inserted into the femur during total hip arthroplasty, sufficient fixation depends on the surgeon’s experience. An objective method of evaluating whether the stem has been correctly fixed may aid clinicians in their decision. We examined the relationship between the sound frequency caused by hammering the stem and the internal stress in artificial femurs, and evaluated the utility of sound frequency analysis to prevent intraoperative fracture. Surgeons inserted one of two types of cementless stems (SL-PLUS and modified CLS) using routine operational procedures into 13 artificial femurs. These are the standard Zweymüllers used in Europe. The difference is the lateral shape;SL-PLUS has holes for removal and the modified CLS has fins to prevent rotation. We estimated stress in the femur via finite element analysis, measured the hammering force, and recorded the sound of hammering for frequency analysis. Finite element analysis revealed that the hammering sound frequency decreased as the maximum stress increased. A decrease in frequency suggested that fixation was sufficient and that continued hammering would increase the risk of fracture. Thus, evaluation of the change in sound frequency during stem insertion may indicate when the hammering force should be reduced, thereby preventing intraoperative periprosthetic fractures. Further frequency change may also predict fractures prior to visual confirmation. We concluded that sound frequency analysis has potential as an objective evaluation method to help prevent intraoperative periprosthetic fractures during stem insertion. When a stem is inserted into the femur during total hip arthroplasty, sufficient fixation depends on the surgeon’s experience. An objective method of evaluating whether the stem has been correctly fixed may aid clinicians in their decision. We examined the relationship between the sound frequency caused by hammering the stem and the internal stress in artificial femurs, and evaluated the utility of sound frequency analysis to prevent intraoperative fracture. Surgeons inserted one of two types of cementless stems (SL-PLUS and modified CLS) using routine operational procedures into 13 artificial femurs. These are the standard Zweymüllers used in Europe. The difference is the lateral shape;SL-PLUS has holes for removal and the modified CLS has fins to prevent rotation. We estimated stress in the femur via finite element analysis, measured the hammering force, and recorded the sound of hammering for frequency analysis. Finite element analysis revealed that the hammering sound frequency decreased as the maximum stress increased. A decrease in frequency suggested that fixation was sufficient and that continued hammering would increase the risk of fracture. Thus, evaluation of the change in sound frequency during stem insertion may indicate when the hammering force should be reduced, thereby preventing intraoperative periprosthetic fractures. Further frequency change may also predict fractures prior to visual confirmation. We concluded that sound frequency analysis has potential as an objective evaluation method to help prevent intraoperative periprosthetic fractures during stem insertion.
作者 Rina Sakai Takeaki Yamamoto Katsufumi Uchiyama Kensuke Fukushima Naonobu Takahira Kazuhiro Yoshida Masanobu Ujihira Rina Sakai;Takeaki Yamamoto;Katsufumi Uchiyama;Kensuke Fukushima;Naonobu Takahira;Kazuhiro Yoshida;Masanobu Ujihira(Department of Biomedical Engineering and Technology, Kitasato University School of Allied Health Sciences, Kanagawa, Japan;Department of Orthopedic Surgery, St. Marianna University School of Medicine, Kanagawa, Japan;Department of Orthopedic Surgery, Kitasato University School of Medicine, Kanagawa, Japan)
出处 《Journal of Biomedical Science and Engineering》 2020年第6期113-119,共7页 生物医学工程(英文)
关键词 Periprosthetic Fracture Total Hip Arthroplasty Hammering Sound Frequency Analysis Periprosthetic Fracture Total Hip Arthroplasty Hammering Sound Frequency Analysis
  • 相关文献

同被引文献8

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部