期刊文献+

用于产品真空定标测试的平行光管设计 被引量:1

Design of Parallel Light Pipe used in Vacuum Calibration Test of Product
在线阅读 下载PDF
导出
摘要 平行光管作为地面定标设备的重要组成部分,该文以大口径、宽谱段、长后截距的平行光管作为研究对象,分别采用了Wetherell式和Cook式离轴三反射系统设计出焦距长为10000mm,工作谱段为400nm~2500nm,视场角为0.3°×0.3°,系统有效口径为Ф620mm的平行光管,并提出了平行光管在真空低温定标试验中通用要求,设计结果表明:Wetherell式离轴三反射系统波像差优于λ/20,系统的后截距长达1.7m,更好地解决了产品真空低温定标测试操作困难的问题,降低了试验成本。 The parallel light pipe is the important part in the field of vacuum calibration test of product. The parallel light pipe with the advantages of large diameter, broad spectrum, long back focal length was studied in this paper. The optical systems with focal length of 10000 mm, spectral region from 400 nm to 2500 nm, field of view angle of 0.3°×0.3°, effective aperture of system of Ф620 mm were designed by used of Wetherell off-axis three-mirror system and Cook off-axis three-mirror system. The generic requirements of the parallel light pipe were proposed in the field of vacuum calibration test of product. The result indicated that wavefront aberration of Wetherell off-axis three-mirror system was better than λ/20, back focal length of the system can attain to 1.7 m, the system had better solved difficulties from operation in the field of vacuum calibration test, and reduced the cost.
作者 陈刚义 马蕾 孙永雪 陈丽 徐骏 CHEN Gang-yi;MA Lei;SUN Yong-xue;CHEN Li;XU Jun(Shanghai Institute of Satellite Equipment,Shanghai 200240,China)
出处 《强度与环境》 CSCD 2019年第1期57-63,共7页 Structure & Environment Engineering
关键词 光学设计 离轴三反 同轴三反 真空定标 后截距 optic system design off-axis three-mirror reflection coaxial three-mirror reflection vacuum calibration back focal length
作者简介 陈刚义(1987—),男,硕士,工程师,研究方向:光学设计,遥感载荷真空低温定标试验。
  • 相关文献

参考文献13

二级参考文献70

共引文献188

同被引文献13

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部