摘要
详细阐述不同雷电类型,例如直接雷、静电感应雷、电磁感应雷的危害机理。结合现场调查情况和实验室的测试情况,分析侵入ZPW-2000A轨道电路的途径,综合分析危害机理及侵入途径后,制定相应的横向、纵向防雷措施,并对“泄”“抗”“悬浮”等防雷特点进行阐述。
This paper elaborates on the hazard mechanisms of different types of lightning,such as direct lightning,electrostatic induction lightning,and electromagnetic induction lightning.Based on on-site investigation and laboratory testing,this paper analyzes the pathways of lightning intrusion into ZPW-2000A track circuits,comprehensively analyzes the hazard mechanisms and intrusion pathways,formulates corresponding horizontal and vertical lightning protection measures,and explains the lightning protection characteristics such as"leakage","resistance",and"suspension".
作者
刘春雷
刘安波
张浩
张家强
Liu Chunlei;Liu Anbo;Zhang Hao;Zhang Jiaqiang(Tongliao Signaling&Communication Depot,China Railway Shenyang Group Co.,Ltd.,Tongliao 028000,China)
出处
《铁路通信信号工程技术》
2024年第6期37-41,63,共6页
Railway Signalling & Communication Engineering
关键词
雷电
直击雷
感应雷
横向防护
纵向防护
转移系数
lightning
direct lightning
induction lightning
horizontal protection
vertical protection
transfer coefficient
作者简介
第一作者:刘春雷(1985-),男,工程师,本科,主要研究方向:铁道信号,邮箱:76021117@qq.com。