摘要
对多名成年男女全年各季节着装行为进行了现场调研,得到了我国成年男女全年各季节典型着装搭配情况。在实验室条件下利用暖体假人模型进行了各季节典型着装搭配下的套装热阻测试,得到了34组成套服装的整体与局部热阻值,建立了全年各季节典型套装的局部服装热阻数据库。在此基础上分析了套装局部与整体热阻值的关系,获得了基于套装整体热阻值的局部热阻预测模型。
Through a field investigation of the dress behavior of many adult men and women in each season throughout the year,the typical dress collocation of Chinese adult men and women in each season throughout the year is obtained.Under laboratory conditions,a thermal manikin model is used to test the thermal resistance of ensembles under typical dress collocation in each season.The overall and local thermal resistance values of 34 sets of ensembles are obtained,and the local thermal resistance database of typical ensembles in each season throughout the year is established.On this basis,the relationship between the local thermal resistance and the overall thermal resistance of ensembles is analysed,and the prediction model of the local thermal resistance based on the overall thermal resistance of ensembles is obtained.
作者
王飞祥
杨柳
赵胜凯
翟永超
Wang Feixiang;Yang Liu;Zhao Shengkai;Zhai Yongchao(State Key Laboratory of Green Building,Xi’an;Xi’an University of Architecture and Technology,Xi’an)
出处
《暖通空调》
2024年第6期147-154,38,共9页
Heating Ventilating & Air Conditioning
关键词
局部服装热阻
整体服装热阻
套装
热舒适
暖体假人
预测模型
local clothing thermal resistance
overall clothing thermal resistance
ensemble
thermal comfort
thermal manikin
prediction model
作者简介
王飞祥,男,1997年生,在读硕士研究生;通信作者:翟永超,710055陕西省西安市碑林区雁塔路13号西安建筑科技大学建筑学院,E-mail:zhaiyongchao@xauat.edu.cn。