电感耦合等离子体原子发射光谱法测定电池用磷酸铁中磷含量 被引量:7

ICP-AES determination of phosphorous content in iron phosphate for battery materials
在线阅读 下载PDF
导出
摘要 建立了电感耦合等离子体原子发射光谱法测定电池用磷酸铁中磷含量的分析方法。试样经盐酸在低温条件下溶解,选择P 177.499 nm作为仪器分析谱线,铁基体效应的影响经直接稀释和两点背景校正法后得以消除。结果表明,在磷质量浓度为0~50μg/mL时,标准曲线线性相关系数大于0.999,方法检出限为0.02%。将该方法应用于电池用磷酸铁样品中磷含量的测定,其相对标准偏差小于0.50%,测定结果与HG/T 4701-2014《电池用磷酸铁》测定值基本一致。 An analytical method was proposed for the determination of phosphorous content in iron phosphate for battery materials using inductively coupled plasma atomic emission spectrometry(ICP-AES).The sample was dissolved with hydrochloric acid at low temperature and P 177.499 nm was selected as the analyzing spectrum line.The matrix effect of iron was eliminated by direct dilution and two-point background correction method.The results showed that the linear correlation coefficient of calibration graph in the range of 0~50 μg/mL of phosphorous mass concentration was over 0.999.The detection limit of this method was 0.02%.The proposed method was successfully applied to the determination of phosphorus in iron phosphate samples and the determined relative standard deviation(RSD) was less than 0.50%.The analytical results were consistent with those obtained by industrial standard method HG/T 4701-2014,Quinoline Phosphomolybdate Gravimetric Method.
作者 胡赠彬 李宗泽 李少华 寸杰 徐永娥 Hu Zengbin;Li Zongze;Li Shaohua;Cun Jie;Xu Yonge(Yunnan Institute of Products Quality Supervision and Inspection,Kunming 650223,China)
出处 《无机盐工业》 CAS CSCD 北大核心 2020年第5期78-80,共3页 Inorganic Chemicals Industry
关键词 电感耦合等离子体原子发射光谱法 磷酸铁 ICP-AES iron phosphate phosphorus
作者简介 胡赠彬(1963-),男,高级工程师,研究方向为产品质量监督检验及标准化研究;通讯作者:李宗泽,E-mail:2008ynu@163.com。
  • 相关文献

参考文献6

二级参考文献50

共引文献59

同被引文献58

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部