摘要 由于高炉煤气燃气机组的燃料特性和受热面的不同,使得传统的性能计算方法不再适用,因此对试验规程中的性能计算方法进行改进,得到了适用于高炉煤气燃气机组直流锅炉的方法。采用二变量Pearson分析法对直流锅炉的效率进行分析,其结果可为电站人员提供技术和理论支撑。 Due to the different fuel characteristics and heating surface of the blast furnace gas unit,the traditional performance calculation is no longer applicable.Therefore,the performance calculation method for the blast furnace gas-fired gas unit DC boiler is improved by the performance calculation method in the test procedure,and the efficiency of the DC boiler is analyzed by the two-variable Person analysis method.The analysis results can provide technical and theoretical support for power station personnel.
作者 李嘉 顾立群 李丹阳 LI Jia;GU Liqun;LI Danyang(Power Plant of Baoshan Iron&Steel Co.,Ltd.,Shanghai201900,China;Shanghai University of Electric Power,Shanghai200090,China)
出处 《上海电力大学学报》 CAS 2020年第2期105-110,共6页 Journal of Shanghai University of Electric Power
关键词 高炉煤气燃气机组 直流锅炉 性能计算 Pearson分析法 blast furnace gas unit direct current boiler performance calculation Pearson analysis
作者简介 李丹阳(1993-),女,硕士。主要研究方向为火电厂自动控制。E-mail:lidanyang@sucdri.com。