期刊文献+

口腔内3种合金共存下的离子析出及表面粗糙度的改变 被引量:3

Change of ion precipitation and surface roughness of three dental alloys coexisting
在线阅读 下载PDF
导出
摘要 目的:研究口腔内3种合金共存下的离子析出及表面粗糙度的改变,为临床合金修复材料的选择提供参考。方法:制作镍铬合金、钴铬合金和金银钯合金标准试件,分为镍铬合金(N组)、钴铬合金(C组)、金银钯合金(A组)、镍铬合金与金银钯合金(NA组)和镍铬合金与钴铬合金(NC组)5组。浸泡于标准电解质溶液(T=37℃,pH=2.31)中,每组平行重复4次。7 d后,用电感耦合等离子体质谱仪检测各组浸提液中离子析出量;用原子力显微镜观察各组试件表面形貌,测量表面粗糙度。采用SPSS 18.0软件包对数据进行统计学分析。结果:析出的镍离子量N组为(1.32±0.03)μg/cm^2,NA组为(2.13±0.07)μg/cm^2,NC组为(1.53±0.08)μg/cm^2,NA组、NC组均显著多于N组,NA组显著多于NC组(P<0.05);析出的铬离子量N组为(0.06±0.01)μg/cm^2,NA组为(0.08±0.01)μg/cm^2,NC组为(0.05±0.01)μg/cm^2,NA组显著多于NC组(P<0.05)。镍铬合金的表面粗糙度N组为(4.60±0.16)nm,NA组为(5.37±0.08)nm,NC组为(5.04±0.15)nm,NA组、NC组均显著大于N组,NA组显著大于NC组(P<0.05)。镍铬合金与金银钯合金或钴铬合金共存时,析出的镍离子量比其单独使用时明显增多,其表面粗糙度明显增大;镍铬合金与金银钯合金共存时比镍铬合金与钴铬合金共存时析出的镍、铬离子量多,镍铬合金的表面粗糙度也大。结论:临床上应尽量避免在患者口腔内同时应用镍铬合金与金银钯合金,或镍铬合金与钴铬合金,尽量避免贱金属的临床使用。 PURPOSE:To study the change of ion precipitation and surface roughness of three dental alloys’coexisting in standard electrolyte solution,in order to provide a reference for the selection of clinical alloy materials.METHODS:Standard samples of Ni-Cr alloy,Co-Cr alloy and Au-Ag-Pd alloy were prepared and divided into 5 groups:Ni-Cr alloy(group N),Co-Cr alloy(group C),Au-Ag-Pd alloy(Group A),Ni-Cr alloy contact with Au-Ag-Pd alloy(group NA),Ni-Cr alloy contact with Co-Cr alloy(group NC).All groups of alloys were soaked in standard electrolyte solution(T=37℃,pH=2.31)for 7 days.Inductively coupled plasma mass spectrometry(ICP-MS)was used to measure the amount of ions released from each group.The surface morphology of each group was observed and the surface roughness(Ra)was measured using atomic force microscope(AFM).SPSS 18.0 software package was used for statistical analysis.RESULTS:The amount of nickel ions released from group N,NA,NC was(1.32±0.03)μg/cm^2,(2.13±0.07)μg/cm^2,(1.53±0.08)μg/cm^2,respectively.Nickel ions of group NA and NC was significantly more than that of group N(P<0.05),nickel ions of group NA was significantly more than that of group NC(P<0.05).The amount of chromium ions released from group N,NA,NC was(0.06±0.01)μg/cm^2,(0.08±0.01)μg/cm^2,(0.05±0.01)μg/cm^2,respectively,the amount of chromium ions of group NA was significantly more than that of group NC(P<0.05).The surface roughness of Ni-Cr alloy in group N,NA,NC was(4.60±0.16)nm,(5.37±0.08)nm,(5.04±0.15)nm,respectively.The surface roughness of Ni-Cr alloy in group NA and group NC was significantly larger than that in group N(P<0.05).When contact with Au-Ag-Pd alloy or Co-Cr alloy,the amount of nickel ions released and the surface roughness of Ni-Cr alloy both significantly increased.Compared with Co-Cr alloy,Au-Ag-Pd alloy caused Ni-Cr alloy to release more nickel,chromium ions and formed a rougher surface.CONCLUSIONS:It is necessary to avoid simultaneous application of Ni-Cr alloy and Au-Ag-Pd alloy,or Ni-Cr alloy and Co-Cr alloy in the patient’s mouth.Non-precious metals should be avoided as much as possible clinically.
作者 张华 周团锋 杨雪 周翊翛 ZHANG Hua;ZHOU Tuanfeng;YANG Xue;ZHOU Yi-xiao(First Clinical Division,Peking University School and Hospital of Stomatology,National Clinical Research Center for Oral Diseases,National Engineering Laboratory for Digital and Material Technology of Stomatology,Beijing Key Laboratory of Digital Stomatology,Beijing 100034;Department of Prosthodoniics,Capital Medical University School of Stomatology,Beijing 100050,China)
出处 《上海口腔医学》 CAS CSCD 北大核心 2020年第1期40-45,共6页 Shanghai Journal of Stomatology
关键词 合金 电偶腐蚀 离子析出 表面粗糙度 Alloy Galvanic corrosion Ion precipitation Surface roughness
作者简介 张华(1987-),女,硕士,住院医师,E-mail:penshuixiaoxiang@sina.com;通信作者:周团锋,E-mail:1442880187@qq.com。
  • 相关文献

参考文献2

二级参考文献30

  • 1李乐乐,刘丽.牙科合金的口腔微生物腐蚀[J].生物医学工程学杂志,2004,21(5):864-866. 被引量:10
  • 2战德松,吕娇,赵奇,于学垠,徐孝荣.磁性附着体中铁素体不锈钢引起小鼠成纤维细胞L929的死亡模式[J].金属学报,2006,42(8):892-896. 被引量:25
  • 3郝建军.牙科材料的细胞毒性试验[J].牙体牙髓牙周病学杂志,1997,7(2):135-137. 被引量:14
  • 4Wataha JC, Nelson SK, Lockwood PE. Elemental release from dental casting alloys into biological media with and without protein. Dent Mater, 2001, 17(5) : 409-414.
  • 5Tokuda E, Ono S, Ishige K, et al. Dysequilibrium between caspases and their inhibitors in a mouse model for amyotrophic lateral sclerosis. Brain Res, 2007, 1148 (5) : 234-242.
  • 6Kato S, Akagi T, Sugimura K, et al. Evaluation of biological responses to polymeric biomaterials by RT-PCR analysis Ⅳ: study of c-myc, c-fos and p53 mRNA expression. Biomaterials, 2000, 21(5) : 521-527.
  • 7Logue SE, Martin SJ. Caspase activation cascades in apoptosis. Biochem SocTrans, 2008, 36 (Pt 1 ) : 1-9.
  • 8Desagher S, Martinou JC. Mitochondria as the central control point of apoptosis. Trends Cell Biol, 2000, 10(9) : 369-377.
  • 9Takeda S, Akiyama M, Sakane K. Effects of metal combinations on cytotoxicity evaluation using a dynamic extraction method. Dent Mater J, 2000, 19(4): 373-380.
  • 10Syverud M, Dahl JE, Herφ H, et al. Corrosion and biocompatibility testing of palladium alloy castings. Dent Mater, 2001, 17(2) : 7-13.

共引文献16

同被引文献42

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部