期刊文献+

液化气塔产品质量波动的原因分析及处理方法 被引量:1

Cause Analysis and Solutions to Product Quality Fluctuation in LPG Tower
在线阅读 下载PDF
导出
摘要 针对雅克拉集气站液化气塔产品饱和蒸气压超标问题,从塔进料、回流量、塔顶冷凝量等方面进行分析,并根据实际情况,从流程、运行管理、操作方式等进行了优化和调整,使产品质量达到了标准要求,提高了雅站储存、长途运输的安全性。 To solve the problem of over high saturated vapor pressure of the product from LPG tower in Yakela Gas Gathering Station,this paper analyzes the tower feed,reflux and overhead condensing volume,and optimizes and adjusts the process,operation management and operating methods according to the actual situations.The product quality meets the requirements of relevant standards,and the storage and long-distance transportation safety of the station is improved.
作者 刘海波 杨刚 宫大印 Liu Haibo;Yang Gang;Gong Dayin(SINOPEC Zhongyuan Oilfield Company,Puyang,Henan,457001;SINOPEC Northwest Oilfield Company,Aksu,Xinjiang,842017)
出处 《石油化工设计》 CAS 2019年第1期41-43,47,I0003,共5页 Petrochemical Design
关键词 液化气塔 饱和蒸汽压高 原因分析 处理方法 LPG tower high saturated vapor pressure cause analysis solution
作者简介 刘海波,男,2004年毕业于中国石油大学(华东)信息工程专业,工程师,主要从事天然气处理装置的运行与管理工作。联系电话:0393-4730320;E-mail:33576228@qq.com.