期刊文献+

超低排放下低浓度可过滤颗粒物的手工测试 被引量:15

Research of low concentration test method of PM for ultra-low emission
在线阅读 下载PDF
导出
摘要 对国内外超低排放条件下烟尘的高精度测试标准进行综述,并评述低浓度烟尘测试准确性,开展超低排放工程的现场实测,对低低温电除尘器、湿法脱硫及湿式电除尘器出口颗粒物浓度进行科学表征,以期为低浓度烟尘测试标准的修制定提供技术支撑。 The relevant test standards at home and abroad was analyzed, the types and reasons of measurement error was studied, and based on this, field testing was done, the ultra-low emission of smoke test accuracy was reviewed, the outlet PM concentration of low-low temperature ESP , WFGD and wet ESP were represented scientifically, which can provide technical support for the smoke test standards.
出处 《中国粉体技术》 CSCD 北大核心 2017年第4期49-53,共5页 China Powder Science and Technology
基金 国家重点研发计划 编号:2016YFC0203704 2016YFC0209107
关键词 烟尘 超低排放 燃煤电厂 误差分析 测量精度 smoke ultra-low emission coal-fired power plant error analysis measurement accuracy
作者简介 刘含笑(1987-),男,工程师,硕士,研究方向为PM2.5捕集增效技术。E-mail:gutounan@163.com。