一种新型光伏光热溶液再生系统性能研究 被引量:5

PERFORMANCE ANALYSIS OF A NEW PV/T DESICCANT REGENERATION SYSTEM
在线阅读 下载PDF
导出
摘要 为了提高太阳能溶液再生系统的可靠性和经济性,提出一种新型光伏光热溶液再生系统,分析该系统的工作原理,建立该系统的耗能模型,并与传统太阳能热再生系统进行对比研究。研究结果表明,在理想运行工况下,新型光伏光热溶液再生系统具有较高的节能潜力。 A new PV/T desiccant regeneration system was proposed in order to improve the reliability and the performance of solar desiccant regeneration system. Analysis of the new system and the solar TH regeneration system was made and the results revealed that the new system will be more energy efficient than the solar TH regeneration system under the ideal operational condition. Among all factors, the most influential one is the concentration of desiccant at the entrance of concentrate cells in the ED regenerator, and the new system should be running under the ideal operational condition as possible.
作者 程清 张小松
出处 《太阳能学报》 EI CAS CSCD 北大核心 2015年第7期1616-1621,共6页 Acta Energiae Solaris Sinica
基金 "十二五"国家科技支撑计划(2011BAJ03B05) 东南大学优秀博士学位论文基金(YBJJ1228)
关键词 液体吸湿剂 溶液再生 溶液预处理 电渗析 liquid desiccant desiccant regeneration desiccant pre-treatment electrodialysis
作者简介 通信作者:程清(1989-),男,博士研究生,主要从事太阳能、制冷空调方面的研究。chengqing890418@sina.com
  • 相关文献

参考文献14

  • 1Zhang Li, Hihara E, Matsuoka F, et al. Experimental analysis of mass transfer in adiabatic structured packing dehumidifier/regenerator with liquid desiccant [J]. International Journal of Heat and Mass Transfer, 2010, 53(13-14) : 2856-2863.
  • 2Jain S, Tripathi S, Das R S. Experimental performance of a liquid desiccant dehumidification system under tropical climates [J ]. Energy Conversion and Management, 2011, 52(6): 2461-2466.
  • 3Audah N, Ghaddar N, Ghali K. Optimized solar- powered liquid desiccant system to supply building fresh water and cooling needs [J]. Applied Energy, 2011, 88 ( 11 ) : 3726-3736.
  • 4Katejanekarn T, Chirarattananon S, Kumar S. An experimental study of a solar-regenerated liquid desiccant ventilation pre-conditioning system [J]. Solar Energy, 2009, $3(6): 920-933.
  • 5Strathmann H. Electrodialysis, a mature technology with a multitude of new applications [ J ]. Desalination, 2010, 264(3) : 268-288.
  • 6Lee H J, Sarfert F, Strathmann H, et al. Designing of an eleetrodialysis desalination plant [J]. Desalination, 2002, 142(3) : 267-286.
  • 7Tsiakis P, Papageorgiou L G. Optimal design of an eleetrodialysis brackish water desalination plant [J]. Desalination, 2005, 173(2): 173-186.
  • 8Li Xiuwei, Zhang Xiaosong. Photovoltaie-eleetrodialysis regeneration method for liquid desiccant cooling system [J]. Solar Energy, 2009, 83(12) : 2195-2204.
  • 9Li Xiuwei, Zhang Xiaosong, Quan Shuo. Single-stage and double-stage photovohaie driven regeneration for liquid desiccant cooling system [J]. Applied Energy,.2011, 88(12): 4908-4917.
  • 10Yin Yonggao, Zhang Xiaosong. Comparative study on internally heated and adiabatic regenerators in liquid desiccant air conditioning system[J]. Building and Environment, 2010, 45(8): 1799-1807.

同被引文献49

引证文献5

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部