摘要
通过对各试件导热系数的测定,分析了水胶比,粉煤灰掺量,骨料掺量和煤矸石陶粒掺量四因素变化对A型GRC墙板导热系数的影响;对比了水胶比、煤矸石陶粒掺量变化下A、B两种板型GRC墙板的导热系数,并对结果进行了综合分析。试验结果表明,高水胶比、高掺量粉煤灰和低煤矸石掺量条件下,A型墙板导热系数低;在一定范围内提高骨料掺量,A型墙板导热系数降低;另外,B型墙板的导热系数远低于A型墙板,对B型墙板而言,各因素的变化对导热系数的影响显著减弱。
Effects of the four influencing factors including W/B, the contents of fly ash, aggregate and coal gangue ce- ramsites on thermal conductivity of A-type Glass-fiber Reinforced Composite (GRC) walls were studied and analyzed. Thermal conductivities of A-type and B-type walls by adjusting W/B and coal gangue ceramsites content were contrasted. The results show that the thermal conductivity of A-type wails is low under the condition of high W/B, high content of fly ash, and low content of coal gangue ceramsites. The thermal conductivity of A-type walls reduces increasing the aggregate content in a certain range; on the other hand, the thermal conductivity of B-type walls is significantly lower than that of A-type walls. The effect of the influencing factors on the thermal conductivity of B-type walls is obviously weakened.
出处
《混凝土与水泥制品》
2015年第5期65-67,70,共4页
China Concrete and Cement Products
基金
国家自然科学基金项目(10662005)
内蒙古自治区高等学校科学研究项目(NJZY12272)
关键词
导热系数
GRC墙板
水胶比
粉煤灰
煤矸石陶粒
Thermal conductivity
Glass-fiber Reinforced Composite (GRC) walls
W/B
Fly ash
C0al gangue ceramsites
作者简介
米力(1979-),男,硕士、讲师。联系电话:15149705068 E—mail:ml1688_2006@126.com