期刊文献+

冬季工况下埋管换热器换热特性实验与模拟对比分析

Comparative analysis of numerical simulation and research on thermal property of vertical buried tube heat exchanger in winter condition
在线阅读 下载PDF
导出
摘要 利用土壤源热泵实验系统,进行不同埋管间距下冬季连续运行实验。采用FLUENT模拟软件建立竖直U型埋管的等效传热模型,对不同实验工况进行了数值模拟,将获得的实验数据与模拟结果进行对比分析。通过分析,得到了不同埋管间距对土壤源热泵系统性能的影响,土壤温度场变化对地埋管换热器换热性能的影响规律。 Based on the experimental ground source heat pump system, researches of winter continuous operation underdifferent experimental borehole spacing were done. A vertical U-shaped ground heat transfer equivalent model was es-tablished by FLUENT software. Numerical simulation with different experiments were analyzed. After that, experimen-tal data and simulation results were compared. Performance affects with different buried tube space and the influence ofheat transfer performance of vertical buried tube heat exchanger with soil temperature changes were analyzed.
出处 《能源工程》 2015年第1期37-43,共7页 Energy Engineering
基金 上海市重点学科建设项目(S30503)
关键词 地埋管换热器 等效模型 数值模拟 传热特性 冬季工况 实验研究 vertical buried tube heat exchanger equivalent model numerical simulation thermal property wintercondition experiment
作者简介 杜诗民(1988-),男,河南商丘人,硕士研究生,主要研究方向为土壤源热泵技术。