摘要 通过分析地埋管换热器的传热特性,建立了地源热泵地埋管换热器数学物理模型,利用FLUENT软件对换热器的传热相干性进行了数值模拟,在此基础上,通过对地埋管换热器传热性能实测与夏季非连续运行工况的模拟结果比较,得到不同埋管间距周围的土壤温度沿径向的变化规律及地埋管传热相干性的影响规律。 With the establishment of mathematical and physical model and numerical simulation of vertical tube by FLUENT, characteris- tics of buried tube heat exchanger of ground source heat pump (GSHP) was analyzed. Based on this information, combined with the simu- lation and measurement of summer discontinuous operation results, the law of different buried tube space on the radial variation of soil temperature and coherent effects of buried tubes heat transfer were got.
出处 《制冷学报》 CAS CSCD 北大核心 2013年第2期55-59,共5页 Journal of Refrigeration
基金 上海市教育委员会重点学科项目(J50502) 2010年上海市研究生创新基金项目(JWCXSL1102)资助~~
关键词 地源热泵 地埋管间距 数值模拟 传热相干性 夏季非连续运行 GSHP buried tube space numerical simulation coherence effects discontinuous operation
作者简介 王瑾,女(1955-),副教授,上海理工大学,13816819989,E—mail:wjljh2003@163.com。研究方向:空调制冷技术开发。
  • 相关文献

参考文献9

  • 1殷平.现代空调[M].北京:中国建筑工业出版社,2001..
  • 2Mustafa Omer, Abdeen. Ground source heat pumps sys- tems and applications [ J ]. Renewable and Sustainable En- ergy Reviews, 2008, 12(2) :344-371.
  • 3杨卫波,施明恒.基于垂直U型埋管换热器的圆柱源理论及其应用研究[J].制冷学报,2006,27(5):51-57. 被引量:14
  • 4Kulcar B, Goricanec D, Krope J. Economy of exploiting heat from low-tem perature geothermal sources using a heat pump [ J ]. Energy and Buildings, 2008, 40 ( 3 ) : 323- 329.
  • 5Denis Marcotte, Philippe Pasquier. Fast fluid and ground temperature computation for geothermal ground loop heat exchanger systems [ J ]. Geothermics, 2008, 37 (6) : 651- 665.
  • 6Deerman J D, Kavanaugh S P. Simulation of vertical U Tube Ground Coupled heat pump systems using the cylin- drical heat source solution [ J ]. ASHRAET ransactions, 1991, 97( 1 ) :287-295.
  • 7田慧峰,王鹏英,曹伟武.垂直U形地埋管换热器长度计算方法研究[J].制冷学报,2008,29(5):28-32. 被引量:8
  • 8黄俊惠,时晓燕,唐志伟.地源热泵U型管地下换热器的准三维模型[J].中国农业大学学报,2004,9(5):51-54. 被引量:13
  • 9Piechowski M. Heat and mass transfer model of a ground heat exchanger: Validation and sensitivity analysis [ J ]. Int J of Energy Res, 1998, 22( 11 ) : 965-979.

二级参考文献23

  • 1侯方卓.用探针法测定材料的导热系数[J].石油大学学报(自然科学版),1994,18(5):94-98. 被引量:24
  • 2田慧峰,王鹏英,曹伟武.大地耦合热泵系统国内外研究近况[J].制冷与空调,2006,6(3):15-20. 被引量:5
  • 3谢汝镛.地源热泵系统的设计[J].现代空调,2001,(10):33-73.
  • 4Gu Yian,O'Neal Dennis L.An analytical solution to transient heat conduction in a composite region with a cylindrical heat source[J].Transactions of the ASME,1995,117:242-248
  • 5Muraya N K,O'Neal D L,Heffington W M.Thermal interference of adjacent legs in a vertical u-tube heat exchanger for a ground-coupled heat pump[J].ASHREAE Trans,1996,102(2):12-21
  • 6Yavuzturk C,Spitler J D,Ress Simon J.A transient two-dimensional finite volume model for the simulation of vertical u-tube ground heat exchangers[J].ASHRAE Trans,1999,105(2):465-474
  • 7Piechowski M.heat and mass transfer model of a ground heat exchanger:validation and sensitivity analysis[J].International Journal of Energy Research,1998,22:965-979
  • 8Mei V C,Emerson C J.New approach for analysis of ground-coil design for applied heat pump systems[J].ASHRAE Trans,1985,91(2):1216-1224
  • 9丁勇 刘宪英 胡鸣明.地热源热泵系统实验研究综述[J].现代空调,2001,(3):11-52.
  • 10R L D Cane. P. eng and D.A. Forgas. Modeling of Ground -Source Heat Pump Performance[G]. ASHRAE Transactions,1991,97(1):909 - 925

共引文献32

同被引文献48

引证文献7

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部