摘要
[目的]降低危重病人胸腹腔引流管的非计划性拔管率。[方法]将99例行胸腹腔穿刺引流病人随机分为对照组和实验组。对照组采用传统的3M透明敷贴加3条胶带固定胸腹腔引流管,实验组采用3M透明敷贴加思乐扣固定胸腹腔引流管。[结果]实验组非计划性拔管率低于对照组(P<0.05)。[结论]3M透明敷贴加思乐扣固定法能有效降低非计划性拔管率。
Objective:To reduce the non-planed decannulation rate of ascites and pleural drainage tube in critically ill patients ethods:A total of 99 cases of patients undergoing ascites and pleural drainage were randoly divided into control group and experiental group.The control group cases used the traditional 3 transparent application plus 3 tapes for fixing chest and abdoinal cavity drainage tube,while the experiental group cases used 3 transparent application and Synopsys lock to fix chest and abdoinal cavity drainage tube.Results:The non-planned decannulation rate of experiental group was significantly lower than that of control group(P0.05).Conclusion:The fixed ethod with 3 transparent application plus Synopsys lock can effectively reduce the non-planned decannulation rate.
出处
《全科护理》
2012年第29期2702-2703,共2页
Chinese General Practice Nursing
关键词
胸腔引流管
腹腔引流管
思乐扣
固定方法
chest drainage tube
abdoinal cavity drainage tube
Synopsys lock
fixed ethod
作者简介
文成,大专,单位:610021,四川大学华西医院