摘要
采用电吸附除盐技术,对循环冷却水系统排污水进行除盐效果中试研究。试验表明电吸附技术对电导率的平均去除率为76.3%,产水率为76.1%,对氯离子、钙离子都有良好的去除效果,产水水质能够达到循环冷却水系统补充水的要求。
Electrosorb technology was used to treat sewage discharged from circulating cooling water system, and its desalination performance was studied through a pilot scale test. The resuhs of the test showed that, using electrosorb technology to treat the said kind of sewage, the average removal rate of conductivity reached 76.3%, the water production rate was 76.1%, the removal rates of chlorine ion and calcium ion were both satisfactory, and the produced water quality could meet the specification for make-up water of circulating cooling water system.
出处
《工业用水与废水》
CAS
2012年第5期71-73,共3页
Industrial Water & Wastewater
关键词
电吸附
循环冷却水
回用水
除盐
electrosorb
circulating cooling water
reclaimed water
desalination
作者简介
李永辉(1974-),男,山东海阳人,工程师,给水排水工程专业,(电子信箱)lyh95812@sohu.com。