儿童前牙区牙槽骨和基骨骨密度的锥形束CT测量 被引量:4

Density of the anterior area of alveolar and basal bones on the children measured by cone beam computed tomography
在线阅读 下载PDF
导出
摘要 目的评估儿童前牙区上下颌牙槽骨和基骨的骨密度。方法选择138例患者的锥形束CT扫描图像,以亨斯菲尔德单位(X线衰减单位Hu)来测定其上下颌切牙区、尖牙区牙槽嵴和基骨骨密质及骨松质的骨密度。结果上颌切牙区左右两侧相同部位间的骨密度值相比较,差异没有统计学意义(P>0.05);下颌切牙区左右两侧相同部位的骨密度值相比较,基骨区舌侧骨密质的骨密度值差异有统计学意义(P=0.012);上颌尖牙区左右两侧相同部位的骨密度值相比较,差异没有统计学意义(P>0.05);下颌尖牙区左右两侧相同部位的骨密度值相比较,牙槽骨和基骨区骨松质的骨密度值差异有统计学意义,P值分别为0.046和0.002。结论本研究可为前牙区微螺旋种植体植入位置和方法提供一定的数据。 Objective The purpose of this investigation was to evaluate density value on anterior of the alveolar and basal bones on children. Methods 138 cases cone beam computed tomography images were selected. The densities of these bones were measured in Hounsfield units (Hu) for the incisor, canine of the anterior area of alveolar and basal bones on the children. Results There is no significant difference on the same position of the maxillary bilateral (right and left) incisors of the density value (P〉0.05). To compare with the incisors of the den- sity value on the same position of the mandibule on left and right, there is significant difference on the base bone on cortical bone density of lingual, P=0.012. There is no significant difference on the same position of the maxillary bilateral (right and left) canine of the density value. To compare with the canine of the density value on the same position of the mandibule on left and right, there is significant difference on the alveolar bone and basal bone cancellous density, P=0.046 and 0.002, respectively. Conclusion These might provide determinate data for anterior teeth zone when selecting sites and placement methods for microscrew implants in the dental arch.
出处 《国际口腔医学杂志》 CAS 2012年第1期25-28,共4页 International Journal of Stomatology
关键词 儿童 牙槽骨 基骨 骨密度 children alveolar bone basal bone bone mineral density
作者简介 王军(1976-),男,甘肃人,主治医师,硕士 【通讯作者】任卫萍,Tel:0931-8281303
  • 相关文献

参考文献12

  • 1Mew J. C4 dispatches[J]. Dent Update, 2000, 27(6):307.
  • 2Houston WJ. The analysis of errors in orthodontic measurements[J]. Am J Orthod, 1983, 83 (5) : 382-390.
  • 3Kau CH, Zhurov A, Richmond S, et al. Facial templates: A new perspective in three dimensions[J]. Orthod Craniofac Res, 2006, 9(1): 10-17.
  • 4Nute SJ, Moss JP. Three-dimensional facial growth studied by optical surface scanning[J]. J Orthod, 2000, 27 (1) :31-38.
  • 5Park HS, Lee Y J, Jeong SH, et al. Density of the alveolar and basal bones of the maxilla and the mandible[J]. Am J Orthod Dentofacial Orthop, 2008, 133(1):30-37.
  • 6栗震亚,黄刚,王军,任卫萍.儿童下颌骨骨密度的定量CT测量研究[J].华西口腔医学杂志,2008,26(4):355-357. 被引量:8
  • 7Truhlar RS, Morris HF, Ochi S, et al. Second-stage failures related to bone quality in patients receiving endosseous dental implants: DICRG Interim Report No.7. Dental Implant Clinical Research Group[J]. Implant Dent, 1994, 3 (4) : 252-255.
  • 8Park HS, Kwon TG. Sliding mechanics with microscrew implant anchorage[J]. Angle Orthod, 2004, 74 (5):703- 710.
  • 9Park HS, Kwon TG, Sung JH. Nonextraction treatment with microscrew implants[J]. Angle Orthod, 2004, 74(4): 539-549.
  • 10el Askary AS, Meffert RM, Griffin T. Why do dental implants fail? Part I [J]. Implant Dent, 1999, 8(2):173- 185.

二级参考文献10

  • 1邹冰爽,曾祥龙,曾应魁.下颌骨骨密度测量的方法和应用[J].中华口腔正畸学杂志,1999,15(4):169-172. 被引量:5
  • 2盛康,袁绍沄.更年期妇女性激素水平与无牙颌下颌骨骨密度、牙槽骨吸收关系的研究[J].华西口腔医学杂志,1993,11(2):115-118. 被引量:7
  • 3王敏,黄琼,胡国瑜.全身骨密度和下颌骨骨密度5年变化的初步研究[J].华西口腔医学杂志,1994,12(3):227-229. 被引量:10
  • 4宋军,雷建伟.偏侧咀嚼对下颌骨骨密度及面部影响的研究[J].实用口腔医学杂志,2005,21(6):849-850. 被引量:5
  • 5Lindh C, Nilsson M, Klinge B, et al. Quantitative computed tomography of trabecular bone in the mandible[J]. Dentomaxillofac Radiol, 1996, 25 (3) : 146-150.
  • 6Johnson K. The determination of the mineral content of the alveolus by non-invasive methods: A preliminary report[J]. Aust Dent J, 1986, 31 (6) :424-433.
  • 7Bridges T, King G, Mohammed A. The effect of age on tooth movement and mineral density in the alveolar tissues of the rat [J]. Am J Orthod Dentofacial Orthop, 1988, 93(3):245-250.
  • 8Yamada K, Kimmel DB. The effect of dietary consistency on bone mass and turnover in the growing rat mandible[J]. Arch Oral Biol, 1991, 36(2) : 129-138.
  • 9Rauch F, Schoenau E. Changes in bone density during childhood and adolescence: An approach based on bone's biological organization[J]. J Bone Miner Res, 2001, 16(4):597-604.
  • 10Kiliaridis S, Bresin A, Holm J, et al. Effects of masticatory muscle function on bone mass in the mandible of the growing rat[J]. Acta Anat (Basel), 1996, 155 (3) : 200.

共引文献7

同被引文献47

  • 1Turkyilmaz I, Turner C, Ozbek EN, et al. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular.
  • 2Park HS, Lee Y J, Jeong SH, et al. Density of the alveolar and basal bones of the maxilla and the mandible. Am J Orthod Dentofacial Orthop, 2008,133 ( 1 ) : 30-37.
  • 3Hansen MA, Hassager C, Overgaard K, et al. Dual-energy x- ray absorptiometry: a precise method of measuring bone mineral density in the lumbar spine. J Nucl Med, 1990,31 (7):1156- 1162.
  • 4Roberts JA, Drage NA, Davies J, et al. Effective dose from cone beam CT examinations in dentistry. Br J Radiol, 2009,82 (973) : 35-40.
  • 5Hashinmto K, Arai Y, Iwai K, et al. A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2003,95 (3):371-377.
  • 6Aranyarachkul P, Caruso J, Gantes B, et al. Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography. Int J Oral Maxillofac Implants, 2005, 20(3) :416-424.
  • 7Wilmes B, Rademacher C, Ohhoff G, et al. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop, 2006,67 (3) : 162-174.
  • 8Rabel A, Ktihler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investi, 2007,11 (3): 257-265.
  • 9Misch CE. Density of bone: effect in treatment planning, surgical approach, and healing. In: Misch CE, editor. Contemporary implant dentistry. St Louis : Mosby, 1993 : 469-485.
  • 10Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent, 1983,50( 1):101-107.

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部