LASIK术前与术后眼压变化的临床观察 被引量:3

Clinical research on the change in intraocular pressure before and after LASIK
在线阅读 下载PDF
导出
摘要 目的探讨LASIK术后眼压测量值的变化及其规律。方法分析LASIK手术前后非接触眼压的测量及相关手术参数。结果术后1周时眼压测量值较术前下降(0.79±0.2614)mmHg,术后眼压和中央角膜厚度(CCT)与术前相比下降,差异有统计学意义(t为4.124和5.325,P<0.05);236眼CCT与眼压呈直线正相关(r=0.486,t=6.524,P<0.05),以CCT为自变量(X),眼压为因变量(Y),直线回归方程r=0.0402×(-7.329),术后每眼CCT平均下降(97.56±7.11)UM,眼压平均降低(3.986±0.61)mmHg。结论判断术后眼压较术前眼压下降与角膜厚度有关。 Objective To investigate the value of intraocular pressure after LASIK.Methods The non-contact measurement of intraocular pressure and related surgical parameters before and after LASIK surgery were analyzed.Results The intraocular pressure decreased with 0.79 ± 0.2614 1 week after operation.The intraocular pressure and central corneal thickness(CCT) were difference between before and after operation.Conclusion There is relationship of IOP decrease and corneal thickness.
作者 周亚军 罗琼
出处 《西部医学》 2011年第10期1930-1931,共2页 Medical Journal of West China
关键词 LASIK 近视 角膜 眼压 LASIK Myopia Cornea Intraocular pressure
  • 相关文献

参考文献3

二级参考文献28

  • 1毛治平,单武强,杨晓宁,吕晓玲,张晓晗,金丽娟.准分子激光角膜上皮瓣下磨镶术临床观察[J].国际眼科杂志,2004,4(5):935-937. 被引量:3
  • 2曹志杰,王勤美.近视LASIK术后角膜膨隆的研究进展[J].国际眼科杂志,2004,4(6):1088-1091. 被引量:10
  • 3杜红俊,徐渊,王英,王雨生.LASIK术后继发性圆锥角膜的预防和处理[J].国际眼科杂志,2005,5(2):376-379. 被引量:12
  • 4晏晓明,李海丽,王捷.三种眼压计在准分子激光原位角膜磨镶术后的应用比较[J].中国实用眼科杂志,2005,23(6):612-615. 被引量:9
  • 5Johnson M, Kass MA, Moses RA, et al. Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol, 1978,96: 664-665.
  • 6Quigley HA,Broman AT.The number of people with glaucoma worldwide in 2010 and 2020.Br J Ophthalmol,2006,90:262-267.
  • 7Kim JH,Sah WJ,Hahn TW,et al.Some problems after photorefractive keratectomy.J Refract Corneal Surg,1994,10:226-230.
  • 8Levy Y,Zadok D,Glovinsky Y,et al.Tono-Pen versus Goldmann tonometry after excimer laser photorefractive keratectomy.J Cataract Refract Surg,1999,25:486-491.
  • 9Garzozi HJ,Chung HS,Lang Y,et al.Intraocular pressure and photorefractive keratectomy:a comparison of three different tonometers.Cornea,2001,20:33-36.
  • 10Kotecha A,White ET,Shewry JM,et al.The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry.Br J Ophthalmol,2005,89:1572-1575.

共引文献25

同被引文献29

  • 1孔宁平.缺血性视神经病变30例临床分析[J].中国交通医学杂志,2006,20(2):214-215. 被引量:1
  • 2Thomas V, Daly MK, Cakiner-Egilmez T, et al.Reliability of tonosafe disposable tonometer prisms:clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study. Eye (London, England), 2011, 25(5):651-656.
  • 3Abiana Quartiero, Pereira, Bernardo Stefano, et al. Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits.Veterinary ophthalmology, 2011, 14(5):321-326.
  • 4Cherney D Z I, Lai V, Miller J A, et al.The angiotensin II receptor type 2 polymorphism influences haemodynamic function and circulating RAS mediators in normotensive humans.Nephrology, dialysis, transplantation:official publication of the European Dialysis and Transplant Association - European Renal Association, 2010. 25(12):4093-4096.
  • 5刘伟民.轴性近视的准分子激光手术设计研究[C].中国医师协会2012年眼科准分子激光角膜屈光手术学术研讨会暨第九届全国眼科准分子激光角膜屈光手术学术研讨会论文集.2012:10-11.
  • 6Udell IJ, Steinemann TL. Orthokeratology: does it live up to ex- pectations [J]. Am J Ophthalmol, 2013,156(6) t1073-1075.
  • 7Leccisotti A. Femtosecond laser - assisted hyperopic laser in situ keratomileusis with tissue - saving ablation: analysis of 800 eyes [J]. J Cataract Refract Surg, 2014,40(7) :1122 -1130.
  • 8Wu D, Wang Y, Zhang L, et al. Corneal biomechanical effects: small - incision lenticule extraction versus femtosecond laser - as- sisted laser in situ keratomileusis [J] . J Cataract Refract Surg, 2014,40(6) :954 -962.
  • 9王润生,吕沛霖.努力提高非动脉炎性前部缺血性视神经病变的诊断和治疗水平[J].中华眼底病杂志,2010,26(4):301-305. 被引量:23
  • 10李名龙,汪珺莉,倪江文,庞洪波.运用彩超技术评价糖尿病患者颈动脉内膜斑块的形成及血流动力学变化[J].淮海医药,2010,28(6):508-509. 被引量:5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部