期刊文献+

Fe/C微电解-Fenton氧化-混凝沉淀-生化法处理抗生素废水的试验研究 被引量:39

STUDY ON THE TREATMENT OF ANTIBIOTIC WASTEWATER WITH FERRIC-CARBON MICROELECTROLYSIS-FENTON OXIDATION-COAGULATION SEDIMENTATION-BIOLOGICAL PROCESS
在线阅读 下载PDF
导出
摘要 采用Fe/C微电解-Fenton氧化-生化组合工艺处理抗生素生产废水,Fe/C微电解单元主要讨论了铁炭体积比、HRT、pH曝气量大小对处理效果的影响;Fenton氧化单元主要讨论了H2O2投加量、pH、HRT对处理效果的影响;混凝沉淀和生物接触氧化处理主要讨论了pH和HRT对各自处理效果的影响。结果表明,在最佳试验参数条件下,废水的色度、COD总的去除率分别为99.93%和99.73%,最终出水色度≤10倍,COD≤50 mg·L-1。 The ferric-carbon electrolysis-Fenton oxidation-coagulation sedimentation-biological contact oxidation combined process was used to treat the antibiotic wastewater.The effect of the volume ratio of ferric to carbon,HRT,pH and aeration rate on the treatment efficiency of wasterwater was discussed in the ferric-carbon electrolysis unit; the effect ofpH, dosing quantity of 30% H2O2,HRT on the treatment efficiency of wasterwater in the Fenton oxidationunitwasdiseussed, meanwhile, theeffect ofpH on the treatment effciency of coaguoation sedimentation and the effect of HRT on thetreatment efficiency of biological contact oxidation were discussed.The results showed that, operated with the optimum parameters,the total chroma removal efficiency andCODremoval efficiency can reach 99.93% and 99.73%, and the effluent chroma and COD can be less than 10(times) and 50 mg·L^-1 respectively.
出处 《水处理技术》 CAS CSCD 北大核心 2011年第3期84-87,共4页 Technology of Water Treatment
基金 国家自然科学基金(40522024) 浙江省重大科技攻关项目(2004C1104) 陕西科技大学研究生创新基金资助项目
关键词 抗生素废水 铁碳微电解 FENTON氧化 生物接触氧化 antibiotic wastewater ferric-carbon microelectrolysis fenton oxidation biological contact oxidation
作者简介 任健(1985-),男,硕士研究生,研究方向为高浓度有毒有机工业废水的高级氧化处理技术联系电话:15191423938:E-mail:qfeng456@126.com
  • 相关文献

参考文献8

二级参考文献91

共引文献350

同被引文献405

引证文献39

二级引证文献168

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部