摘要
根据1913 t/h超临界锅炉启动分离器的结构及设计参数,分析了启动分离器在内压及温度变化作用下的内压应力和温度应力分布,提出了内压应力及温度应力指数,并根据锅炉启停曲线对其疲劳寿命进行了验算。
Based on previous experiences, gained in analyzing strength of boiler structures, the internal pressure incited stress distribution in a 1913 t/h supereritical boiler's start-up separator, as well as its thermal stress distribution, caused by temperature variations, are being analyzed. Indexes of internal pressure incited stress and of thermal stresses are furthermore presented, with which life expectancy calculated, according to the boiler's start-up and shut-down curves. Figs 12, tables 5 and refs 4.
出处
《动力工程》
EI
CAS
CSCD
北大核心
2006年第4期462-466,共5页
Power Engineering
关键词
动力机械工程
超临界锅炉
启动分离器
强度
寿命
power and mechanical engineering
supereritical boiler
start-up separator
strength
life expectancy
作者简介