可逆式轴流通风机的优化设计和实验研究 被引量:7

Experimental study and optimization design of reversible axial fan
在线阅读 下载PDF
导出
摘要 采用流场结构分析和叶片造型调整结合的全三维优化设计方法,对可逆式轴流通风机进行了优化设计,并对样机进行了性能验证实验.结果表明:在不改变风机外径、转速和间隙的情况下,风机的性能得到大幅改善.风机的内部流场合理,没有明显的分离和回流;风机的性能曲线比较平滑,变工况性能好;经性能实验验证,优化设计后的风机各项指标均达到了设计要求. Optimization design of a reversible axial fan was conducted by the method of three dimensional optimization design based on the flow analysis and blade profile modification, validation tests were conducted on a sample fan as well. The results show that the performance of the fan is improved significantly without changes of diameter, rotation speed and clearance. The internal flow field of the fan is reasonable without obvious separations and back flows. The performance of the fan at different flow rate is fine with the smooth performance curves. The three dimensional optimization design of the axial fan is successfully validated by the experimental results.
出处 《煤炭学报》 EI CAS CSCD 北大核心 2006年第1期116-120,共5页 Journal of China Coal Society
基金 中国科学院百人计划资助项目
关键词 轴流通风机 三维 优化设计 axial fan three dimensional optimization design
作者简介 陈海生(1977-),男,山东滕州人,博士,副研究员.Tel:010—62575915,E—mail:chen_hs@mail.etp.ac.cn
  • 相关文献

参考文献7

二级参考文献18

  • 1魏百锁,赵晓虹.摆线S型可反向轴流风机翼型的研究[J].流体工程,1993,21(1):9-12. 被引量:6
  • 2李庆宜.通风机[M].机械工业出版社,1986..
  • 3秦鹏.轴流压气机气动设计[M].北京:国防工业出版社,1978..
  • 4-.中华人民共和国国家标准GB1236-85《通风机空气动力性能试验方法》[M].国家标准局,1985..
  • 5梁锡智.XF5高温排烟风机实验报告[M].中国科学院工程热物理所,1994..
  • 6-.中华人民共和国国家标准GB5045-95《高层民用建筑设计防火规范》[M].北京:中国计划出版社,1995..
  • 7-.中华人民共和国国家标准GB50067-97《汽车库、修车库、停车场设计防火规范》[M].北京:中国计划出版社,1998..