期刊文献+

肾脏循环灌注对比超声声学特征 被引量:3

Expermential study of the characteristics of renal blood flow with contrast ultrasound
在线阅读 下载PDF
导出
摘要 目的探讨肾脏循环灌注对比超声声学显像特点。方法对10条杂种犬注射全氟显声学造影剂进行肾脏对比超声检查。结果肉眼下基础状态肾皮质至肾髓质、肾髓质由外至内呈渐进式显影。计算机视频分析示基础状态下皮质血管容积、血流速度、血流量均大于髓质,皮质和髓质血流速度的差异显著大于血管容积的差异。结论肾脏对比超声检查为研究肾脏循环提供了一个窗口。 Objective To study the characteristics of renal blood flow with contrast ultrasound. Methods The examination of the renal ultrasonography was performed in 10 dogs after intravenous injection of Quanfuxian (a contrast agent consisting of C3F8 microbubbles). Results Contrast visualization appeared in the renal cortex and then in the outer to inner medulla at the baseline level after administration of the contrast agent. Notable differences in the values of microvascular volume (A, which was 120.3 in the corted vs 110.8 in the medulla, P〉0.05), microcirculatory flow velocity (β, which was 1.39 in the corted vs 0.54 in the medulla, P〈0.05), and microcirculatory flow rate (A×β, 167.4 in the corted vs 59.5 in the medulla, P〈0.05) were found between the corted and the medulla, with also marked difference between the the corted-to-the medulla ratios of β and A (0.612 vs 0.078, P〈0.05). Conclusion Contrast ultrasound of the kidney provides a useful means of renal circulatory flow study.
出处 《第一军医大学学报》 CSCD 北大核心 2005年第8期1040-1042,共3页 Journal of First Military Medical University
关键词 肾脏循环 对比超声 肾皮质 肾髓质 renal blood flow contrast ultrasound renal cortex medulla
作者简介 谢晋国(1965-),男,博士,电话:020-61642265.E-mail:xajngo@fimmu.com
  • 相关文献

参考文献11

  • 1Main ML, Grayburn PA. Clinical applications of transpulmonary contrast echocardiography[J]. Am Heart J, 1999, 137(1): 144-55.
  • 2Kevin W, Elizabeth L, Jian PB, et al. Quantification of renal blood flow with contrast-enhanced ultrasound [J]. J Am Coll Cardiol,2001, 37(4): 1135-40.
  • 3Kishimoto N, Mori Y, Nishiue T, et al. Renal blood flow measurement with contrast-enhanced harmonic ultrasonography: evaluation of dopamine-induced changes in renal cortical perfusion in humans[J]. Clin Nephrol, 2003, 59(6): 423-8.
  • 4Villarraga HR, Foley DA, Aeschbacher BC, et al. Destruction of contrast microbubbles during ultrasound imaging at conventional power output[J]. J Am Soc Echocardiogr, 1997, 10(8): 783-91.
  • 5Wei K, Skyba DM, Firschke C, et al. Interactions between microbubbles and ultrasound: In vitro and in vivo observation[J]. J Am Coll Cardiol, 1997, 29(5): 1081-8.
  • 6Lindner JR, Song J, Jayaweera AR, et al. Microvascular rheology of definity micro-bubbles after intra-arterial and intravenous administration[J]. J Am Soc Echocardiogr, 2002, 15(5): 396-403.
  • 7Keller MW, Segal SS, Kaul S, et al. The behavior of sonicated albumin microbubbles with the microcirculation: a basis for their use during myocardial contrast echocardiography [J]. Circ Res,1989, 65(2): 458-67.
  • 8Jayaweera AR, Edwards N, Glasheen WP, et al. In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography: comparison with radiolabeled red blood cells[J]. Circ Res, 1994, 74(6): 1157-65.
  • 9Brenner BM. The Kindey[M]. Philadelphia: Saunders, 1999. 27-31.
  • 10Navar LG, Gilmore JP, Joyner WL, et al. Direct assessment of renal microcirculatory dynamics[J]. Fed Proc, 1986, 45(13): 2851-6.

同被引文献41

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部