期刊文献+

棉织物低甲醛交联阻燃剂的应用研究 被引量:3

Application of low formaldehyde crosslinked flame retardant for cotton fabric
在线阅读 下载PDF
导出
摘要 根据磷氮协效机理,自制了棉用低甲醛交联阻燃剂,测定了阻燃剂的磷氮含量,并用红外光谱仪分析其化学结构。探讨了阻燃整理中阻燃剂用量、催化剂用量、预烘温度和时间、焙烘温度和时间,以及轧余率对阻燃效果的影响,得出最佳阻燃工艺为:阻燃剂500g/L、催化剂22g/L、尿素20g/L、预烘100℃×4min、焙烘165℃×3min、皂洗5min、轧余率100%。整理后,织物上游离甲醛含量小于25mg/kg。 Taking advantage of synergism of nitrogen and phosphorus, low formaldehyde crosslinked flame retardant for cotton fabric is prepared. The contents of nitrogen and phosphorus are determined; the chemical structure is analyzed via infrared spectrum. Effects of concentrations of flame retardant and catalyst, temperature and time of drying and curing on flame retardant efficiency are researched. The optimized conditions are: flame retardant 500 g/L, catalyst 22 g/L, urea 20 g/L, predrying at 100℃ for 4 minutes, curing at 165℃ for 3 minutes, soaping for 5 minutes, pickup 100%. Free formaldehyde in the finished fabric is less than 25mg/kg.
出处 《印染》 北大核心 2005年第15期7-10,共4页 China Dyeing and Finishing
基金 山东省中青年科学家奖励基金资助
关键词 阻燃整理 阻燃剂 甲醛 含量 棉织物 fire proofing fire proofing agent formaldehyde content cotton fabric
  • 相关文献

参考文献5

  • 1Palliser A M,Hoechst U K.Formaldehyde Hazards in Textile Finishing[J].Colourage,1997,(6):279~286.
  • 2单玉华,王旭,徐美英,钱三鸿,毛翠霞.新型阻燃剂乙二胺四甲撑四[双(2-羟基-3-氯丙基)]膦酸酯的合成及应用效果评价[J].精细化工,1998,15(3):35-39. 被引量:2
  • 3Flame-retardant phosphorus-containing epoxy resins, their preparation, compositions, cured products, and uses[P].JP 2002037852.
  • 4上海化工采购供应站技术室.化工商品检验方法[M].上海:化学工业出版社,1988.783-785,231-232.
  • 5金咸穰.染整工艺实验[M].北京:纺织工业出版社,1986.12-126.

共引文献5

同被引文献25

  • 1方志勇.我国纺织品阻燃现状及发展趋势[J].染料与染色,2005,42(5):46-48. 被引量:35
  • 2朱平,王炳,王仑,张建波.无甲醛耐久阻燃剂的制备及应用[J].纺织学报,2005,26(6):112-114. 被引量:13
  • 3纪俊玲,仇振华,蒋菲.超低甲醛阻燃整理工艺探讨[J].印染,2006,32(1):36-38. 被引量:5
  • 4魏治国,缪卫东,林小琴,王龙,章明建,蔡海燕.磷氮阻燃剂在纺织物耐久阻燃整理中的应用[J].江苏纺织,2006(01A):23-26. 被引量:7
  • 5WU Wci-dong,CHARLES Y Q.Comparison of different reactive organnphosphorus flame retardaut agents for eotton:Part 1.The bonding of the flame retardant agents to cotton[J].Polymer Degradation and Stability,2006(91 ):2 541-2 548.
  • 6HORROCKS A R.Flame-retardant finishing of textiles[J].Rev. Prog. Color.,1986(16):62-66.
  • 7HORROCKS A R,HEYWOOD D.Flame-retardant finishes and finishing[C]//Society of Dyers and Colourists,Bradford:UK Conference,2003: 214-220.
  • 8RAYMOND B,DAWSON,SUSAN D.The regulatory status of flame retardants used in electrical equipment and in foam applications[C]//Proceeding of the First Annual Sino-American Joint lnternational Fire Safety Conterence,2006:283-290.
  • 9DROHMANN D,HAM G,TANGE L.The implementation of the WEEE and RollS directive with solutions for plastics with brominated flame retardants[C]//Proceedings of the First Annual Sino-American Joint International Fire Safety Conference,2006:291-302.
  • 10CHEN Wei,GARY C,LICKFIELD,et al.Molecular modeling of cellulose in amorphous state part II:effects of rigid and flexible crosslinks on eellulose[J].Polymer,2004(45):7 357-7 365.

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部