摘要
数字示波器作为一种通用测试测量仪器,自动校正是其必不可少的功能,是实现精确测量的基础。在传统的手动校正垂直灵敏度方法的基础上,提出了一种以偏置电压为内部校正源的方法,实现数字示波器增益自动校正功能,从而解脱人为操作,简化校正过程,提高校正效率。
Digital oscilloscope as a general measurement instrument, automatic calibration is an essential feature, and the basis for accurate measurements. Based on traditional manual calibration of vertical sensitivity, the bias voltage served as the internal reference voltage, applying for automatic calibration of gain that decreased human operations, simplified the calibration process and improved accuracy.
作者
丁浩
康云
赵佳
曾浩
Ding Hao;Kang Yun;Zhao Jia;Zeng Hao(School of Humanities and Information Management,Chengdu Medical College,Chengdu 610500,China;college of Automation Engineering,University of Electronic Science and Technology,Chengdu 611731,China)
出处
《电子测量技术》
2020年第8期175-178,188,共5页
Electronic Measurement Technology
关键词
垂直灵敏度
偏置电压
增益自动校正
vertical sensitivity
bias voltage
automatic calibration of gain