摘要
提出通过引入线路电压和开关位置的判据,对区域备自投系统逻辑控制策略进行优化。优化后的区域备自投系统有效避免了变电站轻负荷运行状态下发生母线PT断线时误动作的风险,并能准确判出母线PT断线,对其他备自投系统的逻辑控制策略提供参考案例。
This paper proposes to optimize the logic control strategy of regional standby automatic switching system by introducing the criteria of line voltage and switch position.The optimized regional standby automatic switching system effectively avoids the risk of misoperation in case of bus PT disconnection under light load operation of the substation,and can accurately judge the bus PT disconnection,which provides a reference case for the logic control strategy of other standby automatic switching systems.
作者
郑睿
ZHENG Rui(Nanjing University of Technology,Jiangsu 211100,China)
出处
《电子技术(上海)》
2021年第8期82-83,共2页
Electronic Technology
关键词
区域备自投
轻负荷
PT断线
逻辑控制策略
策略优化
regional standby automatic switching
light load
Pt disconnection
logic control strategy
strategy optimization
作者简介
郑睿,南京工业职业技术大学,研究方向:控制技术。