基于线性化及两步法核电站低加系统数据校正模型研究

Research on data correction model of low pressure feed water heater system of nuclear power plant based on linearization and two-step method
在线阅读 下载PDF
导出
摘要 可靠的在线监测系统对保障核电站性能监控与优化运行具有重要意义,而监测系统的可靠性与传感器的布置、精度以及冗余性等密切相关。以某核电站的低加系统为研究对象,分析了线性化方法及两步法两种双线性的数据校正问题的求解过程。最后通过案例数据,分析了两种方法在校正结果、计算时间、故障引入的表现,分析结果可有效指导实际电厂低加系统实施数据校正过程。 A reliable online monitoring system is of great significance to ensure the performance monitoring and optimal operation of nuclear power plants, and the reliability of the monitoring system is closely related to the arrangement, accuracy and redundancy of sensors. This paper takes the low pressure feed water heater system of a nuclear power plant as the research object, and analyzes the solution process of the linearization method and the two-step method for bilinear data correction problems. Finally, through the case data, the performance of the two methods in the correction results, calculation time, and fault introduction is analyzed. The analysis results can effectively guide the data correction process of the actual power plant low pressure feed water heater system.
作者 罗芳绘 张功庆 杨宵 李飞 张弦 陈建文 齐克林 李青 Luo Fanghui;Zhang Gongqing;Yang Xiao;Li Fei;Zhang Xian;Chen Jianwen;Qi Kelin;Li Qing(Nuclear Power Simulation and Control Technology Research Center,Research Institute of Nuclear Power Operation,Wuhan 430223,China)
出处 《电子技术应用》 2022年第S01期60-65,共6页 Application of Electronic Technique
关键词 低加系统 数据校正 双线性 线性化 两步法 ABP system data correction bilinear equation linearization two-step method
作者简介 罗芳绘(1989-),女,本科,主要研究方向:核电站数据协调。