摘要 格栅作为影响风道性能的关键部件,为了提升风道效率、降低噪声,采用仿真手段研究不同类型的格栅对风道性能的影响。研究表明:平面格栅风量比鼓包格栅的风量大,同转速下风量提升34%,可显著降低同风量下的噪声。因相比于鼓包的格栅,平面格栅的扇叶尖到导圈面的竖直距离与轮毂到格栅底部距离的比值越大,风扇电机的附近的涡流更少,流场更加均匀。 The grille is a key component affecting the performance of the duct.For increasing the efficiency of the duct and decreasing the noise,it is studied by simulation that the influence of the performance of the different ducts.The research shows that the air volume of flat grille is larger than that of tubercle grille.After the flat grid is adopted,the air volume is increased by 34%at the same speed,and the noise decreases significantly at the same air volume.Compared with the tubercle grille,the larger the vertical distance from the blade tip of the plane grid to the flow guides surface,the less the vortex near the fan motor is,and the more flow field is uniformed.
作者 付杰 刘裕 孙义祥 石滋基 曾耀坚 吕根贵 FU Jie;LIU Yu;SUN Yixiang;SHI Ziji;ZENG Yaojian;LV Gengui(Hisense Home Appliances Group Co.,Ltd.,Foshan 528305)
出处 《家电科技》 2022年第S01期512-516,共5页 Journal of Appliance Science & Technology
关键词 筒式顶出风空调 鼓包格栅 平格栅 仿真 The cylinder top air condition The tubercle grille The flat grille Simulation
作者简介 付杰,硕士。研究方向:空调等家电的噪声与振动控制。地址:广东省佛山市顺德区容桂桥东路12号。E-mail:fujie4@hisense.com。
  • 相关文献

参考文献4

二级参考文献16

  • 1丁国良,胡俊伟.导流罩对空调器室外机噪声的影响[J].机械工程学报,2006,42(3):136-141. 被引量:22
  • 2杭寅,刘东,黄艳,刘俊.某高层建筑空调室外机的气流模拟及优化[J].建筑热能通风空调,2006,25(3):12-16. 被引量:15
  • 3招伟.空调室外机噪声源的系统分析及确定[J].制冷与空调,2007,7(2):24-28. 被引量:18
  • 4Abdollah Avara,Ehsan Daneshgar.Optimum placement of condensing units of split-type air-conditioners by numerical simulation.Energy and Buildings,2008,40:1268-1272.
  • 5T T Chow,Z Lin,Q W Wang.Studying thermal performance of split-type air-conditioners at building re-entrant via computer simulation∥Sixth international IBPSA Conference Kyoto.Japan,1999:1357-1363.
  • 6Gang Wang,Yafeng Hu,Songtao Hu.Thermal environment of outdoor units of VRV system in high-rise building∥Proceedings:Building Simulation 2007.2007:1109-1114.
  • 7H Xue,B Xu,J Wu,et al.Prediction of temperature rise near condensing units in the confined space of a high-rise building.Building and Environment,2007,42:2480-2487.
  • 8T T Chow,Z Lin,J P Liu.Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance.Energy and Buildings,2002,34:237-244.
  • 9T T Chow,Z Lin,Q W Wang.Effect of building re-entrant shape on performance of air-cooled condensing units.Energy and Buildings,2000,32:143-152.
  • 10陶文铨.数值传热学.2版.西安交通大学出版社.2004.