Beckman AU5800全自动生化分析仪体液样本基质效应评估 被引量:3

Evaluation of matrix effect for body fluid on Beckman AU5800 system
原文传递
导出
摘要 目的:通过回收试验评估Beckman AU5800全自动生化分析仪测定胸水、腹水、脑脊液、穿剌液等标本类型多项生化检测项目的基质效应。方法:收集临床新鲜胸水、腹水、引流液和脑脊液,使用Beckman AU5800全自动生化分析仪检测系统测定乳酸脱氢酶(LDH)、天冬氨酸氨基转移酶(AST)、淀粉酶(AMY)、总胆固醇(CHOL)、总蛋白(TP)、白蛋白(ALB)、葡萄糖(GLU)等项目。通过回收试验计算回收率评估各种体液的基质偏差大小。结果:在本研究中,使用Beckman AU5800全自动生化分析仪测定血清样本的检测程序对新鲜体液标本以上各项测定的回收率均在(100%±10%)范围内,为临床可接受范围之内。结论:使用Beckman AU5800全自动生化分析仪测定血清样本的检测程序测定新鲜体液标本的基质效应在可接受偏差之内,测定结果准确可靠。 Objective:To evaluate the matrix effect of body fluid specimens(including pleura,ascites,drainage and cerebrospinal)by performing recovery study on Beckman AU5800 system.Method:Collecting clinical body fluid specimens(including pleura,ascites,drainage and cerebrospinal),and then all the chemistry analytes,including lactate dehydrogenase(LDH),aspartate aminotransferase(AST),amylase(AMY),total cholesterol(CHOL),total protein(TP),albumin(ALB)and glucose(GLU),were tested on Beckman AU5800 system.The rate of recovery study(spiking with high concentration serum)was calculated to evaluate the matrix deviation of the body fluids.Result:The recovery rates of the majority of body fluid specimens were within the acceptable limit of(100%±10%).Conclusion:The body fluid matrix interferences for commonly requested chemistry analytes in body fluid specimens are acceptable on Beckman AU5800 system.
作者 石伍和 刘凤 张科 张德太 SHI Wuhe;LIU Feng;ZHANG Ke;ZHANG Detai(Department of Clinical Laboratory,Union Hospital,Tongji Medical College,Huazhong University of Science&Technology,Wuhan,430022,China)
出处 《临床血液学杂志(输血与检验)》 CAS 2020年第1期109-111,共3页 Journal of Clinical Hematology(Blood Transfusion & Laboratory Medicine)
关键词 体液 基质效应 回收试验 body fluid matrix effect recovery study
作者简介 通信作者:张德太,E-mail:Detaizhangwh@163.com
  • 相关文献

参考文献6

二级参考文献26

  • 1刘蕾,周伟燕,孙春华,胡欣,张传宝,王抒,董军,申子瑜,陈文祥.同位素稀释液相色谱串联质谱法测定血清总胆固醇[J].中华检验医学杂志,2007,30(3):250-254. 被引量:14
  • 2陈文祥.临床检验参考测量系统与临床检验分析质量保证[J].中华检验医学杂志,2007,30(4):478-480. 被引量:51
  • 3阿拉法特,邢文革.制备样品基质效应的评估及控制[J].中国医药导刊,2007,9(2):158-159. 被引量:11
  • 4National Committee for Clinical Laboratory Standards. Evaluation of matrix effects: Approved guideline -Second Edition[S]. NCCLS Document EP14-A2, 2005.
  • 5Chen WX, Li PX, Wang S, et al. Serum cholesterol determined by liquid chromatography with 6- chlorostigmasterol as internal standard [J]. Clin Chem, 1993,39 : 1602-1607.
  • 6Dong J,Chen W,Wang S,et al. Jones oxidation and high performance liquid chromatographic analysis of cholesterol in biological samples[J].J Chromatogr B, 2007,858 : 239-246.
  • 7International Organization for Standardization. In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials[S]. ISO 17511,2003.
  • 8[1]Lawson N S, Williams T L, Long T, Matrix effects and accuracy assessment. Identifying matrix-sensitive methods from real-time proficiency testing data [ J ]. Arch Patho 1 Lab M ed, 1993 117 (4):401-411.
  • 9[2]Kroll M H, Elin R J. Interference with clinical laboratory analyses [ J ]. Clin Chem 1994 40 ( 11 ): 1996-2005.
  • 10Evaluation of matrix effects.Clinical and Laboratory Standards Institute[J].EP14-A,2001.

共引文献33

同被引文献53

引证文献3

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部