期刊文献+
共找到14,392篇文章
< 1 2 250 >
每页显示 20 50 100
Battlefield dynamic scanning and staring imaging system based on fast steering mirror 被引量:4
1
作者 CHANG Tianqing WANG Quandong +2 位作者 ZHANG Lei HAO Na DAI Wenjun 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第1期37-56,共20页
This paper presents the design of an experimental battlefield dynamic scanning and staring imaging system based on a fast steering mirror(FSM), which is capable of real-time monitoring of hot targets and wide-area rec... This paper presents the design of an experimental battlefield dynamic scanning and staring imaging system based on a fast steering mirror(FSM), which is capable of real-time monitoring of hot targets and wide-area reconnaissance of hot regions. First,the working principle and working sequence of the FSM are briefly analyzed. The mathematical model of the FSM system is built by modeling its dynamic and electrical properties, and the rationality of the model is validated by means of model identification. Second,the influence of external sources of disturbance such as the carrier and moment on the control precision of the FSM is effectively suppressed by the jointly controlling of proportional integral(PI)and disturbance observer(DOB), thus realizing a high precision and strong robustness control of the FSM system. Then, this paper designs an experimental prototype and introduces a special optical structure to enable the infrared camera to share the FSM with the visible light camera. Finally, the influence of the velocity difference between the mirror of the FSM and the rotating platform on the imaging quality of the system is experimentally analyzed by using the image sharpness evaluation method based on point sharpness. A good dynamic scanning and staring imaging result is achieved when the velocity of these two components correspond. 展开更多
关键词 fast STEERING mirror (FSM) dynamic scanning and staring backscanning compensation DISTURBANCE OBSERVER (DOB) point sharpness.
在线阅读 下载PDF
Characterization of stress corrosion crack growth of 304 stainless steel by electrochemical noise and scanning Kelvin probe 被引量:14
2
作者 赵茹 张正 +2 位作者 石江波 陶蕾 宋诗哲 《Journal of Central South University》 SCIE EI CAS 2010年第1期13-18,共6页
The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/... The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/L NaC1 + 0.01 mol/L Na2S203 solution under slow-strain-rate-testing (SSRT) conditions. Moreover, the characteristics of L-crack's surface morphology and potential distribution with scanning Kelvin probe (SKP) before and after SSRT were also discussed. Compared with S-crack, L-crack is propagated and the features of crack propagation can be obtained. After propagation, the noise amplitudes increase with increasing stress and accelerating corrosion, the white noises at low and high frequencies (WE and WH) of the later stage are one order of magnitude larger than that at early stage in the current power spectral densities (PSDs). The potential PSDs also increase, but WH disappears. In addition, the crack propagation can be demonstrated according to variation of probability distribution, surface morphology and potential distribution. 展开更多
关键词 304 stainless steel fatigue pre-cracking electrochemical noise stress corrosion cracking (SCC) scanning Kelvin probe
在线阅读 下载PDF
Automated extraction of expressway road surface from mobile laser scanning data 被引量:3
3
作者 TRAN Thanh Ha TAWEEP Chaisomphob 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第7期1917-1938,共22页
This paper presents a voxel-based region growing method for automatic road surface extraction from mobile laser scanning point clouds in an expressway environment.The proposed method has three major steps:constructing... This paper presents a voxel-based region growing method for automatic road surface extraction from mobile laser scanning point clouds in an expressway environment.The proposed method has three major steps:constructing a voxel model;extracting the road surface points by employing the voxel-based segmentation algorithm;refining the road boundary using the curb-based segmentation algorithm.To evaluate the accuracy of the proposed method,the two-point cloud datasets of two typical test sites in an expressway environment consisting of flat and bumpy surfaces with a high slope were used.The proposed algorithm extracted the road surface successfully with high accuracy.There was an average recall of 99.5%,the precision was 96.3%,and the F1 score was 97.9%.From the extracted road surface,a framework for the estimation of road roughness was proposed.Good agreement was achieved when comparing the results of the road roughness map with the visual image,indicating the feasibility and effectiveness of the proposed framework. 展开更多
关键词 mobile laser scanning SEGMENTATION road surface EXPRESSWAY VOXELIZATION point cloud
在线阅读 下载PDF
3D cavity detection technique and its application based on cavity auto scanning laser system 被引量:4
4
作者 刘希灵 李夕兵 +2 位作者 李发本 赵国彦 秦豫辉 《Journal of Central South University of Technology》 EI 2008年第2期285-288,共4页
Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. Th... Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. The conventional cavity detection methods and their limitation were analyzed. Those methods cannot form 3D model of underground cavity which is used for instructing the cavity disposal; and their precisions in detection are always greatly affected by the geological circumstance. The importance of 3D cavity detection in metal mine for safe exploitation was pointed out; and the 3D cavity laser detection method and its principle were introduced. A cavity auto scanning laser system was recommended to actualize the cavity 3D detection after comparing with the other laser detection systems. Four boreholes were chosen to verify the validity of the cavity auto scanning laser system. The results show that the cavity auto scanning laser system is very suitable for underground 3D cavity detection, especially for those inaccessible ones. 展开更多
关键词 cavity detection 3D laser detection cavity auto scanning laser system
在线阅读 下载PDF
A Study of Precision Factors of Large-scale Object Surface Profile Laser Scanning Measurement
5
作者 WANG Long-shan 1, LI De-long 2, NIE Meng-yu 3, ZHENG Z hong-wei 1 (1. The Science of Mechanical and Engineering College of Ji lin University, Changchun 130025, China 2. The Factory Automation Deparment of Shanghai Marine Equipment Research Institute, Shanghai 200031,China 3. Changchun Lat Exhaust Systems Company Ltd., Changchun 130022, China) 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期162-,共1页
In this paper, we presented a method of using the l as er scanning triangulation for the non-contact 3D surface profile measurement of large-scale object. The characteristic of large-scale object non-contact mea surem... In this paper, we presented a method of using the l as er scanning triangulation for the non-contact 3D surface profile measurement of large-scale object. The characteristic of large-scale object non-contact mea surement is analyzed and the measuring method is proposed. Main factors influenc ing measurement precision such as image distortion and accurate designation of s peckle center are analyzed and methods of solving these problems are proposed. W e designed a combined filter by which the pulse noise and the Gaussian noise of speckle image can be eliminated efficiently. Using the characteristic of intensi ty distribution of laser speckle image we proposed a new approximating method th at could locate the center of laser speckle image at sub-pixel. The auxiliary v ariables are set to linearize the relationship between the image displacement an d the distance, the accurate values of laser triangulation system parameters cou ld be calibrated accurately and the measuring precision is increased remarkabl y. Using the above techniques we designed a measuring system based on laser sc anning triangulation. The results of the experiment show that these methods can raise the measuring precision of large-scale 3D surface profile effectively. 展开更多
关键词 large-scale object laser scanning precision fa ctors 3D measurement
在线阅读 下载PDF
Electronic Scanning of Uterine Endometrium in Postpartum Cow
6
作者 TIANWen-ru HEJian-bin 《Journal of Northeast Agricultural University(English Edition)》 CAS 2000年第2期118-124,共7页
Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was de... Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was demonstrated by scanning electron microscope through a series of endometrium biopsy.Some part of the endometrium was damaged after calving and its adjacent endometrium cells became necrosis and exfoliated during the first 7 days post-partum;the cilium and microvillus of the epithelial cell in the undamaged area of the endometrium disappeared.By 26 days postpartum the damaged area reduced and the cilium and microvillus increased in their numbers.The damaged tissues were all repaired by day 60 postpartum. 展开更多
关键词 postpartum cow uterine involution scanning electron microscope
在线阅读 下载PDF
Simple and Rapid Thin-layer Chromatography Method for Quantitative Measurement of Free Cholesterol in Serum
7
作者 李克 《医学研究生学报》 CAS 1990年第2期171-175,共5页
ABSTRACT A quantitative method for the assay of free cholesterol has been described in this paper. The experimental conditions for the determination of cholesterol in serum by Thin-layer chromatography were disscused.... ABSTRACT A quantitative method for the assay of free cholesterol has been described in this paper. The experimental conditions for the determination of cholesterol in serum by Thin-layer chromatography were disscused. The solvent System was petroleum ether-ethyl acetate-glacial acetic acid (8o:20:1) and the spra-ying reagent was a solution of sulphuric acid and vanillin. Under the selected con-ditions, the peak area was linearly related to the cholesterol amount for the range between 80~700 ng per spot. The intraplate and interplate coefficients were 2.4% and 7.4% respectively. The recovery of cholesterol was 101.6%. The method presented was simple, rapid and accurate. The results of experi-mental investigation and clinical application were satisfactory. 展开更多
关键词 Determination of CHOLESTEROL free CHOLESTEROL thin-layer chro-matography.
在线阅读 下载PDF
Raman Spectroscopic Core Scanning for Iron Ore Characterisation
8
作者 Wells M A Ramanaidou E R 《矿物学报》 CAS CSCD 北大核心 2013年第S1期107-107,共1页
Automated core scanning technologies for mineralogical characterisation of diamond core, drill chips pulps is now an established technique, particularly in the Australian iron ore industry, for mineral analysis in exp... Automated core scanning technologies for mineralogical characterisation of diamond core, drill chips pulps is now an established technique, particularly in the Australian iron ore industry, for mineral analysis in exploration and mining. Application of reflectance spectroscopy over the 400–2500 nm, visible to near-infrared wavelength range, has been used to characterise the iron ore oxide mineralogy of bedded iron deposit (BID) derived iron ores in India (Thangavelu et al., 2011) and Brazil (da Costa et al., 2009), and used to define the ore and gangue (e.g., clay) mineralogy in ironstone or channel iron deposits (CID) in the Pilbara region of Western Australia (e.g., Haest et al., 2012). 展开更多
关键词 RAMAN spectroscopy IRON ore CORE scanning IRON oxides GOETHITE HEMATITE magnetite quartz carbonate silicate
在线阅读 下载PDF
Scanning Photoelectrochemical Microscopic Study in Photoinduced Electron Transfer of Supramolecular Sensitizers-TiO_(2)Thin Films Systems
9
作者 Sheng-Ya Zhang Min Yao +5 位作者 Ze Wang Tian-Jiao Liu Rong-Fang Zhang Hui-Qin Ye Yan-Jun Feng Xiao-Quan Lu 《电化学》 CAS 北大核心 2023年第6期65-76,共12页
Crafting charge transfer channels at titanium dioxide(TiO_(2))based photoanodes remain a pressing bottleneck in solar-to-chemical conversion technology.Despite the tremendous attempts,TiO_(2)as the promising photoanod... Crafting charge transfer channels at titanium dioxide(TiO_(2))based photoanodes remain a pressing bottleneck in solar-to-chemical conversion technology.Despite the tremendous attempts,TiO_(2)as the promising photoanode material still suffers from sluggish charge transport kinetics.Herein,we propose an assembly strategy that involves the axial coordination grafting metalloporphyrin-based photosensitizer molecules(MP)onto the surface-modified TiO_(2)nanorods(NRs)photoanode,forming the composite MP/TiO_(2)NRs photoelectrode.As expected,the resulted unique MPB/TiO_(2)NRs photoelectrode displays significantly improved photocurrent density as compared to TiO_(2)NRs alone and MPA/TiO_(2)NRs photoelectrode.Scanning photoelectrochemical microscopy(SPECM)and intensity modulated photocurrent spectroscopy(IMPS)were employed to systematically evaluate the continuous photoinduced electron transfer(PET)dynamics for MP/TiO_(2)NRs photoelectrode.According to the data fitting,it is found that the photoelectron transfer rate(keff)constant for the MPB/TiO_(2)NRs is about 2.6 times higher than that for the pure TiO_(2)NRs under light irradiation.The high kinetic constant for the MPB/TiO_(2)NRs was ascribed to that the conjugated molecules MPB of D-A structure can effectively accelerate intramolecular electrons transfer as well as promote electrons taking part in the reduction reaction of I3to Iin the novel charge transfer channel.The results demonstrated in this study are expected to shed some light on investigating the mechanism in the charge transfer process of artificial photosynthesis and constructing efficient photoelectrodes. 展开更多
关键词 PHOTOSENSITIZER TiO_(2)nanorods scanning photoelectrochemical microscopy Photoexcited electron transfer
在线阅读 下载PDF
3D laser scanning strategy based on cascaded deep neural network
10
作者 Xiao-bin Xu Ming-hui Zhao +4 位作者 Jian Yang Yi-yang Xiong Feng-lin Pang Zhi-ying Tan Min-zhou Luo 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第9期1727-1739,共13页
A 3D laser scanning strategy based on cascaded deep neural network is proposed for the scanning system converted from 2D Lidar with a pitching motion device. The strategy is aimed at moving target detection and monito... A 3D laser scanning strategy based on cascaded deep neural network is proposed for the scanning system converted from 2D Lidar with a pitching motion device. The strategy is aimed at moving target detection and monitoring. Combining the device characteristics, the strategy first proposes a cascaded deep neural network, which inputs 2D point cloud, color image and pitching angle. The outputs are target distance and speed classification. And the cross-entropy loss function of network is modified by using focal loss and uniform distribution to improve the recognition accuracy. Then a pitching range and speed model are proposed to determine pitching motion parameters. Finally, the adaptive scanning is realized by integral separate speed PID. The experimental results show that the accuracies of the improved network target detection box, distance and speed classification are 90.17%, 96.87% and 96.97%, respectively. The average speed error of the improved PID is 0.4239°/s, and the average strategy execution time is 0.1521 s.The range and speed model can effectively reduce the collection of useless information and the deformation of the target point cloud. Conclusively, the experimental of overall scanning strategy show that it can improve target point cloud integrity and density while ensuring the capture of target. 展开更多
关键词 scanning strategy Cascaded deep neural network Improved cross entropy loss function Pitching range and speed model Integral separate speed PID
在线阅读 下载PDF
基于深度学习的大规模室外场景Scan2BIM研究综述 被引量:1
11
作者 莫洋 王晶 +4 位作者 蒋海峰 张业星 曲柄宇 王雷 冯卓航 《计算机辅助设计与图形学学报》 北大核心 2025年第6期905-931,共27页
当前,大规模室外基础设施的数字化需求持续扩大,基于深度学习的自动扫描到建筑信息模型(scanning to building information modeling, Scan2BIM)通过卓越的特征学习能力和自动化流程显著提升了建模精度和构建速度,在结构复杂的室外场景... 当前,大规模室外基础设施的数字化需求持续扩大,基于深度学习的自动扫描到建筑信息模型(scanning to building information modeling, Scan2BIM)通过卓越的特征学习能力和自动化流程显著提升了建模精度和构建速度,在结构复杂的室外场景重建中发挥了关键作用.文中介绍了Scan2BIM的4大核心模块及其相关研究进展.其中,针对3D点云获取模块,从采集设备与采集来源2个维度概括了3D点云数据采集的技术发展,并着重梳理了代表性3D点云数据集;根据学习方式的不同,将大规模点云对齐算法划分为基于优化和深度学习2大类,并从精准度、计算效率、鲁棒性等多维度对比分析了相关工作;在点云分割模块中,分别对点云全景分割和点云实例分割算法通过统一的评估指标进行了整理归纳;对于BIM自动化建模,简述了BIM核心互操作标准体系,并分类总结了多种几何实体建模与关系建模算法.最后,通过深入分析和前瞻性探讨,指出了现阶段大规模室外场景建模的高效性、精准性、泛化性与统一性的无法有效结合的问题;未来将重点围绕多源数据融合建模、精度与鲁棒性协同优化、端到端Scan2BIM通用框架构建以及大模型应用与探索等方向展开. 展开更多
关键词 scan2BIM 深度学习 3D点云 逆向建模 大规模室外场景
在线阅读 下载PDF
New method for analyzing recrystallization kinetics of deformed metal by differential scanning calorimeter
12
作者 陈建 马晓光 +3 位作者 李军 要玉宏 严文 范新会 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期849-854,共6页
The drawn copper wires have been analyzed by differential scanning calorimeter(DSC) and a new method, which uses DSC measurements to determine the Johnson-Mehl-Avrami-Kolmogorov(JMAK) exponent via introducing Arrheniu... The drawn copper wires have been analyzed by differential scanning calorimeter(DSC) and a new method, which uses DSC measurements to determine the Johnson-Mehl-Avrami-Kolmogorov(JMAK) exponent via introducing Arrhenius behavior and modifying the baseline of DSC curves, has been proposed. The results show that JMAK exponent and recrystallization activation energy of the drawn copper wires with a strain of 2.77 are about 2.39 and 125 k J/mol, respectively. The line linking the tangency points of DSC curve hypotenuse can be used as the baseline when calculating recrystallization fraction. The JMAK exponent obtained by the DSC method is in a good agreement with that obtained by microhardness measurements. Compared to traditional methods to measure the exponent, the proposed method is faster and less labor intensive. 展开更多
关键词 crystallization kinetics differential scanning calorimeter Johnson-Mehl-Avrami-Kolmogorov(JMAK) exponent deformed metal
在线阅读 下载PDF
2-D localization system utilizing M-sequence encoded laser beam scanning
13
作者 Shinji Ohyama Kiyoshi Tanaka Junya Takayama 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第3期408-413,共6页
In this paper, as the active position measurement system, a novel method for a two-dimensional localization system using M-sequence signal is proposed. The feature of this system is to realize a position measurement o... In this paper, as the active position measurement system, a novel method for a two-dimensional localization system using M-sequence signal is proposed. The feature of this system is to realize a position measurement only by scanning the encoded laser beams from fixing points to a measurement field, and by observing it. First, both the system configuration and encoding method were practically considered, and an order and an initial value of M-sequence signal were selected for encoding. This method is based on discrete angle measurement therefore the resolution has its own limitation. To overcome this limitation, analogue phase shift detecting method was introduced. System design was performed and applied to position measurement experiments. The experimental results show that the measurement error of the analogue method is 1/3 of that of the discrete method. 展开更多
关键词 激光电子束扫描 位置测量 二维定位系统 M序列 离散法
在线阅读 下载PDF
基于Scan-to-BIM的现有农村建筑改造的零碳建筑数字孪生评价研究
14
作者 赵亮 王海宁 +3 位作者 侯佳松 崔骜然 张雪吉 李庆龄 《西安建筑科技大学学报(自然科学版)》 北大核心 2025年第2期280-287,共8页
全球变暖、碳排放剧增以及对石化能源过度依赖等问题正日益引起各行业的关注.占总能耗约1/3的建筑行业更需要有效的管理和使用可再生能源.本研究提出一个利用激光扫描技术识别和评估现有农村建筑实现零碳建筑的框架.该框架将点云数据转... 全球变暖、碳排放剧增以及对石化能源过度依赖等问题正日益引起各行业的关注.占总能耗约1/3的建筑行业更需要有效的管理和使用可再生能源.本研究提出一个利用激光扫描技术识别和评估现有农村建筑实现零碳建筑的框架.该框架将点云数据转化为BIM模型,在获得现有建筑的BIM模型后,进行能源性能建模,并对现有农村建筑改造方案进行数字孪生评价.研究的目的是根据零碳建筑的概念对现有建筑改造方案进行评估,旨在提高当前建筑的能源利用效率,并利用清洁能源提供建筑能源需求.研究结果表明,适合本研究案例零碳建筑解决方案可以降低18.4%的建筑能源成本,提高24.1%的太阳能光伏发电量和降低能源需求6206.9 kgCO_(2) eq/a. 展开更多
关键词 零碳建筑 scan-to-BIM 数字孪生 建筑能耗模型 碳排放
在线阅读 下载PDF
AL-Scan、IOL-Master和A超测量白内障患者眼轴长度的准确性和一致性分析 被引量:11
15
作者 孙飒 郭海科 《眼科新进展》 CAS 北大核心 2016年第9期876-878,共3页
目的比较AL-Scan、IOL-Master和A超测量白内障患者眼轴长度(axial length,AL)的准确性和一致性。方法选取年龄相关性白内障患者95例(142眼),术前分别应用AL-Scan、IOL-Master和A超进行AL测量。根据AL将患者分为AL≤22 mm(20眼)、22mm<... 目的比较AL-Scan、IOL-Master和A超测量白内障患者眼轴长度(axial length,AL)的准确性和一致性。方法选取年龄相关性白内障患者95例(142眼),术前分别应用AL-Scan、IOL-Master和A超进行AL测量。根据AL将患者分为AL≤22 mm(20眼)、22mm<AL≤26 mm(98眼)和AL>26 mm(24眼)3组。应用方差分析对3种方法测量的结果进行比较,应用Bland-Altman法对其一致性进行分析。结果 AL≤22 mm组AL-Scan、IOL-Master和A超测得AL结果分别为(21.53±0.30)mm、(21.54±0.29)mm及(21.51±0.30)mm,差异无统计学意义(P>0.05);22 mm<AL≤26 mm组分别为(23.68±0.76)mm、(23.71±0.77)mm及(23.65±0.75)mm,差异无统计学意义(P>0.05);AL>26 mm组分别为(28.46±1.60)mm、(28.50±1.62)mm及(28.40±1.63)mm,差异无统计学意义(P>0.05)。AL测量的95%一致性界限范围是0.20 mm(AL-Scan和IOL-Master)、1.12 mm(IOLMaster和A超)和1.12 mm(AL-Scan和A超)。结论 AL-Scan、IOL-Master和A超测量白内障患者AL同样准确,但AL-Scan与IOL-Master之间具有良好的一致性。 展开更多
关键词 眼轴长度 AL—scan IOL—Master A超
在线阅读 下载PDF
基于Agisoft PhotoScan的无人机影像快速拼接在新农村规划中的应用 被引量:11
16
作者 李秀全 陈竹安 张立亭 《湖北农业科学》 2016年第3期743-745,共3页
以新农村建设规划中存在的问题为基础,提出了基于Agisoft Photo Scan无人机影像的快速拼接方法在新农村建设规划中的应用,给新农村建设规划测量带来了极大的便利,可满足新农村建设的需要。
关键词 新农村建设规划 Agisoft PHOTO scan 无人机 快速拼接
在线阅读 下载PDF
MSP430单片机中SCAN IF模块在流量检测中的应用 被引量:4
17
作者 徐爱华 罗琴 《湖南农业大学学报(自然科学版)》 CAS CSCD 北大核心 2007年第4期510-512,共3页
介绍了利用LC传感器实现旋转运动测量的原理,阐述了用MSP430单片机中的SCAN IF模块实现流量检测的设计.
关键词 MSP430单片机 scan IF模块 流量检测
在线阅读 下载PDF
T-Scan系统的特点及其临床应用 被引量:4
18
作者 于婷婷 宋光保 《国际口腔医学杂志》 CAS 2013年第1期113-116,共4页
T-Scan系统能精确记录咬合接触的时间、力量、面积和动态分析咬合接触情况,自问世以来通过产品的不断更新与发展,使其更好地运用于口腔临床和科研工作中。本文就T-Scan系统的特点和临床应用作一综述。
关键词 T—scan系统 咬合接触 咬合分析 临床应用
在线阅读 下载PDF
Scan Worx人体3D测量解决方案及其应用 被引量:1
19
作者 黄丽 施亦东 陈衍夏 《皮革科学与工程》 CAS 2007年第2期56-59,共4页
介绍了来自德国Vitronic公司的3D人体测量系统ScanWorx的系统组成、测量原理和应用功能,并对目前服装企业的应用状况提出了建议。
关键词 scan Worx 3D测量 人体扫描
在线阅读 下载PDF
神经精神病学临床评定表(SCAN)在精神分裂症临床表型界定中的应用 被引量:1
20
作者 原岩波 舒良 《中国心理卫生杂志》 CSSCI CSCD 北大核心 2003年第11期774-777,共4页
目的 :使用半定式诊断工具神经精神病学临床评定表 (SCAN)进行有关精神分裂症临床表型界定方面的探索。方法 :对初步诊断为精神分裂症的住院患者使用SCAN核实ICD -10诊断 ,共收集 80例 ,采用SCAN诊断软件辅助诊断并得出症状组和症状群资... 目的 :使用半定式诊断工具神经精神病学临床评定表 (SCAN)进行有关精神分裂症临床表型界定方面的探索。方法 :对初步诊断为精神分裂症的住院患者使用SCAN核实ICD -10诊断 ,共收集 80例 ,采用SCAN诊断软件辅助诊断并得出症状组和症状群资料 ,用主成分分析等方法进行处理。结果 :根据对SCAN症状群的主成分分析 ,精神分裂症的临床相可以划分为以精神病性症状、阴性症状和抑郁症状为主的三个维度 ;而精神病性症状内部可以区分出特征性幻听、思维障碍和被动体验、怪异妄想以及非特异性病理症状四个维度的划分。结论 :根据精神分裂症临床相的维度划分 ,提出按照操作性标准 (如一级症状 )、阴性症状和情感症状三级标准划分临床表型的假说。 展开更多
关键词 神经精神病学临床评定表 scan 精神分裂症 临床表型 界定 应用
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部