The work takes a new liquid-cooling plate in a power battery with pin fins inside the channel as the object.A mathematical model is established via the central composite design of the response surface to study the rel...The work takes a new liquid-cooling plate in a power battery with pin fins inside the channel as the object.A mathematical model is established via the central composite design of the response surface to study the relationships among the length,width,height,and spacing of pin fins;the maximum temperature and temperature difference of the battery module;and the pressure drop of the liquid-cooling plate.Model accuracy is verified via variance analysis.The new liquid-cooling plate enables the power battery to work within an optimal temperature range.Appropriately increasing the length,width,and height and reducing the spacing of pin fins could reduce the temperature of the power battery module and improve the temperature uniformity.However,the pressure drop of the liquid-cooling plate increases.The structural parameters of the pin fins are optimized to minimize the maximum temperature and the temperature difference of the battery module as well as the pressure drop of the liquid-cooling plate.The errors between the values predicted and actual by the simulation test are 0.58%,4%,and 0.48%,respectively,which further verifies the model accuracy.The results reveal the influence of the structural parameters of the pin fins inside the liquid-cooling plate on its heat dissipation performance and pressure drop characteristics.A theoretical basis is provided for the design of liquid-cooling plates in power batteries and the optimization of structural parameters.展开更多
This paper has an objective to show a developed quantitative criterion,based in two mathematical variables that explicit the deviation degree of a normal situation,applying simultaneously data from terminal impedances...This paper has an objective to show a developed quantitative criterion,based in two mathematical variables that explicit the deviation degree of a normal situation,applying simultaneously data from terminal impedances and frequency response.Based in more than 100-measured equipment,of different applications(step-up transformer,transmission transformer,etc.,),for a period of 10 years,the work presents some examples of practical application of this methodology in Brazilian Electrical System.展开更多
Aiming at evaluating and predicting rapidly and accurately a high sensitivity receiver’s adaptability in complex electromagnetic environments,a novel testing and prediction method based on dual-channel multi-frequenc...Aiming at evaluating and predicting rapidly and accurately a high sensitivity receiver’s adaptability in complex electromagnetic environments,a novel testing and prediction method based on dual-channel multi-frequency is proposed to improve the traditional two-tone test.Firstly,two signal generators are used to generate signals at the radio frequency(RF)by frequency scanning,and then a rapid measurement at the intermediate frequency(IF)output port is carried out to obtain a huge amount of sample data for the subsequent analysis.Secondly,the IF output response data are modeled and analyzed to construct the linear and nonlinear response constraint equations in the frequency domain and prediction models in the power domain,which provide the theoretical criteria for interpreting and predicting electromagnetic susceptibility(EMS)of the receiver.An experiment performed on a radar receiver confirms the reliability of the method proposed in this paper.It shows that the interference of each harmonic frequency and each order to the receiver can be identified and predicted with the sensitivity model.Based on this,fast and comprehensive evaluation and prediction of the receiver’s EMS in complex environment can be efficiently realized.展开更多
The traditional voltage stability analysis method is mostly based on the deterministic mode1.and ignores the uncertainties of bus loads,power supplies,changes in network configuration and so on.However,the great expan...The traditional voltage stability analysis method is mostly based on the deterministic mode1.and ignores the uncertainties of bus loads,power supplies,changes in network configuration and so on.However,the great expansion of renewable power generations such as wind and solar energy in a power system has increased their uncertainty,and仃aditional techniques are limited in capturing their variable behavior.This leads to greater needs of new techniques and methodologies to properly quan tify the voltage stability of power systems.展开更多
Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converter...Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converters since the differential equation order increases very high. We have to search other way to establish mathematical modelling for power DC/DC converters.We have theoretically defined a new concept-Energy Factor (EF) in this paper and researched the relations between EF and the mathematical modelling for power DC/DC converters. EF is a new concept in power DC/DC conversion technology, which thoroughly differs from the traditional concepts such as power factor (PF), power transfer efficiency (η), total harmonic distortion (THD) and ripple factor (RF). EF and the subsequential EFV (and EFVD) can illustrate the system stability, reference response and interference recovery. This investigation is very helpful for system design and DC/DC converters characteristics foreseeing. Two DC/DC converters: Buck converter and Super-Lift Luo-Converter as the samples are analysed in this paper to demonstrate the applications of EF, EFV (and EFVD), PE, SE, VE (and VED), time constant τ and damping time constant τd.展开更多
The bridge piles located in high-steep slopes not only endure the loads from superstructure, but also the residual sliding force as well as the resistance from the slope. By introducing the Winkler foundation theory, ...The bridge piles located in high-steep slopes not only endure the loads from superstructure, but also the residual sliding force as well as the resistance from the slope. By introducing the Winkler foundation theory, the mechanical model of piles-soils-slopes system was established, and the equilibrium differential equations of pile were derived. Moreover, an analytic solution for identifying the model parameters was provided by means of power series method. A project with field measurement was compared with the proposed method. It is indicated that the lateral loads have great influences on the pile, the steep slope effect is indispensable, and reasonable diameter of the pile could enhance the bending ability. The internal force and displacements of pile are largely based upon the horizontal loads applied on pile, especially in upper part.展开更多
Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and re...Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.展开更多
针对传统谐波责任划分方法需采用专门同步设备监测数据,且需基于等值电路模型划分谐波责任,工程应用较为复杂等不足,采用现有谐波监测装置非同步测量数据,提出一种综合考虑了数据非同步性、场景划分和数据相关性的谐波责任划分方法。首...针对传统谐波责任划分方法需采用专门同步设备监测数据,且需基于等值电路模型划分谐波责任,工程应用较为复杂等不足,采用现有谐波监测装置非同步测量数据,提出一种综合考虑了数据非同步性、场景划分和数据相关性的谐波责任划分方法。首先,对原始非同步监测数据集采用分段聚合近似算法进行降噪预处理,利用形状动态时间规整算法(shape dynamic time warping,ShapeDTW)实现数据匹配对齐;然后,利用点排序识别聚类结构的聚类算法(ordering points to identify the clustering structure,OPTICS)划分场景以处理电力系统中因负荷投切和无功补偿装置切换等情况导致的谐波责任变化;最后,基于相关性分析构建场景谐波责任和总谐波责任指标,在指标构建的过程中引入了场景时长占比这一因素以得到更加科学合理的总谐波责任值。通过仿真验证和电网实例验证,该方法能基于现有非同步性监测数据实现各用户合理时间尺度动态谐波责任划分,可为工程上的快速谐波责任划分提供一定的新思路和新方法。展开更多
基金supported by the Education and Teaching Research Project of Universities in Fujian Province(FBJY20230167).
文摘The work takes a new liquid-cooling plate in a power battery with pin fins inside the channel as the object.A mathematical model is established via the central composite design of the response surface to study the relationships among the length,width,height,and spacing of pin fins;the maximum temperature and temperature difference of the battery module;and the pressure drop of the liquid-cooling plate.Model accuracy is verified via variance analysis.The new liquid-cooling plate enables the power battery to work within an optimal temperature range.Appropriately increasing the length,width,and height and reducing the spacing of pin fins could reduce the temperature of the power battery module and improve the temperature uniformity.However,the pressure drop of the liquid-cooling plate increases.The structural parameters of the pin fins are optimized to minimize the maximum temperature and the temperature difference of the battery module as well as the pressure drop of the liquid-cooling plate.The errors between the values predicted and actual by the simulation test are 0.58%,4%,and 0.48%,respectively,which further verifies the model accuracy.The results reveal the influence of the structural parameters of the pin fins inside the liquid-cooling plate on its heat dissipation performance and pressure drop characteristics.A theoretical basis is provided for the design of liquid-cooling plates in power batteries and the optimization of structural parameters.
文摘This paper has an objective to show a developed quantitative criterion,based in two mathematical variables that explicit the deviation degree of a normal situation,applying simultaneously data from terminal impedances and frequency response.Based in more than 100-measured equipment,of different applications(step-up transformer,transmission transformer,etc.,),for a period of 10 years,the work presents some examples of practical application of this methodology in Brazilian Electrical System.
基金supported by the National Natural Science Foundation of China(62071473).
文摘Aiming at evaluating and predicting rapidly and accurately a high sensitivity receiver’s adaptability in complex electromagnetic environments,a novel testing and prediction method based on dual-channel multi-frequency is proposed to improve the traditional two-tone test.Firstly,two signal generators are used to generate signals at the radio frequency(RF)by frequency scanning,and then a rapid measurement at the intermediate frequency(IF)output port is carried out to obtain a huge amount of sample data for the subsequent analysis.Secondly,the IF output response data are modeled and analyzed to construct the linear and nonlinear response constraint equations in the frequency domain and prediction models in the power domain,which provide the theoretical criteria for interpreting and predicting electromagnetic susceptibility(EMS)of the receiver.An experiment performed on a radar receiver confirms the reliability of the method proposed in this paper.It shows that the interference of each harmonic frequency and each order to the receiver can be identified and predicted with the sensitivity model.Based on this,fast and comprehensive evaluation and prediction of the receiver’s EMS in complex environment can be efficiently realized.
文摘The traditional voltage stability analysis method is mostly based on the deterministic mode1.and ignores the uncertainties of bus loads,power supplies,changes in network configuration and so on.However,the great expansion of renewable power generations such as wind and solar energy in a power system has increased their uncertainty,and仃aditional techniques are limited in capturing their variable behavior.This leads to greater needs of new techniques and methodologies to properly quan tify the voltage stability of power systems.
文摘Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converters since the differential equation order increases very high. We have to search other way to establish mathematical modelling for power DC/DC converters.We have theoretically defined a new concept-Energy Factor (EF) in this paper and researched the relations between EF and the mathematical modelling for power DC/DC converters. EF is a new concept in power DC/DC conversion technology, which thoroughly differs from the traditional concepts such as power factor (PF), power transfer efficiency (η), total harmonic distortion (THD) and ripple factor (RF). EF and the subsequential EFV (and EFVD) can illustrate the system stability, reference response and interference recovery. This investigation is very helpful for system design and DC/DC converters characteristics foreseeing. Two DC/DC converters: Buck converter and Super-Lift Luo-Converter as the samples are analysed in this paper to demonstrate the applications of EF, EFV (and EFVD), PE, SE, VE (and VED), time constant τ and damping time constant τd.
基金Project(51408066)supported by the National Natural Science Foundation of China
文摘The bridge piles located in high-steep slopes not only endure the loads from superstructure, but also the residual sliding force as well as the resistance from the slope. By introducing the Winkler foundation theory, the mechanical model of piles-soils-slopes system was established, and the equilibrium differential equations of pile were derived. Moreover, an analytic solution for identifying the model parameters was provided by means of power series method. A project with field measurement was compared with the proposed method. It is indicated that the lateral loads have great influences on the pile, the steep slope effect is indispensable, and reasonable diameter of the pile could enhance the bending ability. The internal force and displacements of pile are largely based upon the horizontal loads applied on pile, especially in upper part.
基金Project Supported by Science and Technology Fund of Fujian E-lectric Power Limited Company(NC2006044)Scientific Research Fund of Fujian Education Depart ment(JB06045)
文摘Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.
文摘针对传统谐波责任划分方法需采用专门同步设备监测数据,且需基于等值电路模型划分谐波责任,工程应用较为复杂等不足,采用现有谐波监测装置非同步测量数据,提出一种综合考虑了数据非同步性、场景划分和数据相关性的谐波责任划分方法。首先,对原始非同步监测数据集采用分段聚合近似算法进行降噪预处理,利用形状动态时间规整算法(shape dynamic time warping,ShapeDTW)实现数据匹配对齐;然后,利用点排序识别聚类结构的聚类算法(ordering points to identify the clustering structure,OPTICS)划分场景以处理电力系统中因负荷投切和无功补偿装置切换等情况导致的谐波责任变化;最后,基于相关性分析构建场景谐波责任和总谐波责任指标,在指标构建的过程中引入了场景时长占比这一因素以得到更加科学合理的总谐波责任值。通过仿真验证和电网实例验证,该方法能基于现有非同步性监测数据实现各用户合理时间尺度动态谐波责任划分,可为工程上的快速谐波责任划分提供一定的新思路和新方法。