Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochran...Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation.展开更多
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d...A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil.展开更多
Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component p...Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component phases of the cement paste such as pores, hydration products, and unhydrated clinker particles were segmented from each other based on their 3D image grey levels; their relative contents were also calculated with the software, and the data are 61.2%, 0% and 38.8% at the beginning of hydration and 11.8%, 78.5% and 9.7% at 28 d age, respectively. The hydration degree of cement paste at different ages was compared with the experimental data acquired by loss on ignition (LOI) tests. The results show that the calculated and measured data reasonably agree with each other, which indicates that micro-CT is a useful and reliable approach to characterize the micro structure evolution of hydrating cement paste.展开更多
A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,...A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,a hybrid regularizations-based iterative Newton method is implemented to provide stable inverse solutions.Furthermore,a dual mesh scheme and an adjoint method are adopted to reduce the computation cost and improve the efficiency of reconstruction.Simultaneous reconstruction of both acoustic velocity and attenuation coefficient for a reinforced concrete model is achieved with multiple frequency data.The algorithm is evaluated with numerical simulation under various practical scenarios including varied transmission/receiving modes,different noise levels,different source/detector numbers,and different contrast levels between the heterogeneity and background region.Results obtained suggest that the algorithm is insensitive to noise,and the reconstructions are quantitatively accurate in terms of the location,size and acoustic properties of the target over a range of contrast levels.展开更多
Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) a...Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.展开更多
目的:探讨双源CT多期增强双能量成像在鉴别肺癌与肺炎性结节/肿块的应用价值。方法:对42例肺结节或肿块患者行双能量平扫及肺动脉期(PP)、主动脉期(AP)、静脉期(VP)及延迟期(DP)增强扫描。测量感兴趣区的平扫CT值、PP、AP、VP及DP的标...目的:探讨双源CT多期增强双能量成像在鉴别肺癌与肺炎性结节/肿块的应用价值。方法:对42例肺结节或肿块患者行双能量平扫及肺动脉期(PP)、主动脉期(AP)、静脉期(VP)及延迟期(DP)增强扫描。测量感兴趣区的平扫CT值、PP、AP、VP及DP的标准化碘浓度(NIC)及40 keV、100 keV图像CT值,计算PP、AP、VP及DP的40 keV图像净增CT值(d_(CT))和40~100 keV区间的能谱曲线斜率(λ_(HU))。比较两组间各参数的差异并进行统计学分析。结果:经手术切除或穿刺活检病理证实,或通过临床诊治过程明确诊断,肺癌组22例、炎性组20例。PP、AP、VP及DP的NIC值、CT值40 ke V、CT值100 ke V炎性组均高于肺癌组;AP、VP及DP的d_(CT)值及λ_(HU)炎性组高于肺癌组,PP的d_(CT)值及λ_(HU)炎性组略低于肺癌组;炎性组与肺癌组比较,VP及DP的NIC值、d_(CT)值差异有统计学意义(P<0.05)。结论:多期增强双能量成像对肺癌与肺炎性结节/肿块的鉴别诊断具有较大的应用价值。展开更多
文摘Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation.
基金Projects(41572277,41877229)supported by the National Natural Science Foundation of ChinaProject(2015A030313118)supported by the Natural Science Foundation of Guangdong Province,ChinaProject(201607010023)supported by the Science and Technology Program of Guangzhou,China
文摘A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil.
基金Project(2009CB623201) supported by the National Basic Research Program of ChinaProjects(50902106, 51272193) supported by the National Natural Science Foundation of ChinaProject(NCET-10-0660) supported by New Century Excellent Talents in Universities of China
文摘Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component phases of the cement paste such as pores, hydration products, and unhydrated clinker particles were segmented from each other based on their 3D image grey levels; their relative contents were also calculated with the software, and the data are 61.2%, 0% and 38.8% at the beginning of hydration and 11.8%, 78.5% and 9.7% at 28 d age, respectively. The hydration degree of cement paste at different ages was compared with the experimental data acquired by loss on ignition (LOI) tests. The results show that the calculated and measured data reasonably agree with each other, which indicates that micro-CT is a useful and reliable approach to characterize the micro structure evolution of hydrating cement paste.
基金Project(31200748)supported by the National Natural Science Foundation of China
文摘A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,a hybrid regularizations-based iterative Newton method is implemented to provide stable inverse solutions.Furthermore,a dual mesh scheme and an adjoint method are adopted to reduce the computation cost and improve the efficiency of reconstruction.Simultaneous reconstruction of both acoustic velocity and attenuation coefficient for a reinforced concrete model is achieved with multiple frequency data.The algorithm is evaluated with numerical simulation under various practical scenarios including varied transmission/receiving modes,different noise levels,different source/detector numbers,and different contrast levels between the heterogeneity and background region.Results obtained suggest that the algorithm is insensitive to noise,and the reconstructions are quantitatively accurate in terms of the location,size and acoustic properties of the target over a range of contrast levels.
基金Project(61171133)supported by the National Natural Science Foundation of ChinaProject(11JJ1010)supported by the Natural Science Fund for Distinguished Young Scholars of Hunan Province,ChinaProject(61101182)supported by the National Natural Science Foundation for Young Scientists of China
文摘Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.
文摘目的:探讨双源CT多期增强双能量成像在鉴别肺癌与肺炎性结节/肿块的应用价值。方法:对42例肺结节或肿块患者行双能量平扫及肺动脉期(PP)、主动脉期(AP)、静脉期(VP)及延迟期(DP)增强扫描。测量感兴趣区的平扫CT值、PP、AP、VP及DP的标准化碘浓度(NIC)及40 keV、100 keV图像CT值,计算PP、AP、VP及DP的40 keV图像净增CT值(d_(CT))和40~100 keV区间的能谱曲线斜率(λ_(HU))。比较两组间各参数的差异并进行统计学分析。结果:经手术切除或穿刺活检病理证实,或通过临床诊治过程明确诊断,肺癌组22例、炎性组20例。PP、AP、VP及DP的NIC值、CT值40 ke V、CT值100 ke V炎性组均高于肺癌组;AP、VP及DP的d_(CT)值及λ_(HU)炎性组高于肺癌组,PP的d_(CT)值及λ_(HU)炎性组略低于肺癌组;炎性组与肺癌组比较,VP及DP的NIC值、d_(CT)值差异有统计学意义(P<0.05)。结论:多期增强双能量成像对肺癌与肺炎性结节/肿块的鉴别诊断具有较大的应用价值。