The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty line...The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty lines.With the goal of achieving“carbon peak and carbon neutrality”,the schemes for clean energy generation have rapidly developed.Moreover,new energy-consuming equipment has been widely connected to the power grid,and the operating characteristics of the power system have significantly changed.Consequently,these have impacted traditional fault identification methods.Based on the time-frequency characteristics of the fault waveform,new energy-related parameters,and deep learning model,this study proposes a fault identification method suitable for scenarios where a high proportion of new energy is connected to the power grid.Ten parameters related to the causes of transmission line fault and new energy connection scenarios are selected as model characteristic parameters.Further,a fault identification model based on adaptive deep belief networks was constructed,and its effect was verified by field data.展开更多
This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT)...This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT) equation, the time-domain analytic solutions are obtained and expressed in an infinite geometric series. Moreover, it is shown that there exist only finite nonzero terms in the infinite geometric series if the time variate is at a finite interval. In other word, the time-domain analytic solutions are expanded in a finite geometric series indeed if the time variate is at a finite interval. The computed results are subsequently compared with transient responses obtained by using the frequency-domain BLT equation via a fast Fourier transform, and the agreement is excellent.展开更多
An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulat...An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.展开更多
Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical polluti...Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding.展开更多
A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/...A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.展开更多
On the basis of quantization of charge, the loop equations of quantum circuits are investigated by using the Helsenberg motion equation for a mesoscopic dissipation transmission line. On the supposition that the syste...On the basis of quantization of charge, the loop equations of quantum circuits are investigated by using the Helsenberg motion equation for a mesoscopic dissipation transmission line. On the supposition that the system has a symmetry under translation in charge space, the quantum current and the quantum energy spectrum in the mesoscopic transmission llne are given by solving their eigenvalue equations. Results show that the quantum current and the quantum energy spectrum are not only related to the parameters of the transmission llne, but also dependent on the quantized character of the charge obviously.展开更多
In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption ...In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption of small rotation quantity, the factors affecting the induced voltage and their effects are analyzed and then an efficient method to calculate the average voltage is presented when the distribution of the random rotation angles is uniform in [-π, π]. The results show that voltage variation is mainly due to the change of the source term. The effects of the source term increase linearly with the magnitude of the incident wave, change periodically with the rotation angle, and are larger in the high frequency range than in the low frequency range. The results show that the average voltages obtained by the proposed method agree well with those via the Monte Carlo method and the proposed method is much more efficient. The results also imply that the effect of random rotation is more important than that of random translation.展开更多
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bra...Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines.展开更多
The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental pl...The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines.展开更多
A fabrication technology of GaAs planar Schottky varactor diode (PSVD) is successfully developed and used to design and manufacture CaAs-based monolithic frequency multiplication based on 23-section nonlinear transm...A fabrication technology of GaAs planar Schottky varactor diode (PSVD) is successfully developed and used to design and manufacture CaAs-based monolithic frequency multiplication based on 23-section nonlinear transmission lines (NLTLs) consisting of a coplanar waveguide transmission line and periodically distributed PSVDs. The throughout design and optimization procedure of 23-section monolithic NLTLs for frequency multiplication in the k-band range is based on a large signal equivalent model of PSVD extracted from small-signal S-parameter measurements. This paper reports that the distributed SPVD exhibits a capacitance ratio of 5.4, a normalized capacitance of 0.86 fF/μm2 and a breakdown voltage in excess of 22 V. The integrated 23-section NLTLs fed by 20-dBm input power demonstrates a 26-GHz peak second harmonic output power of 14-dBm with 25.3% conversion efficiency in the second harmonic output frequency range of 6 GHz-26 GHz.展开更多
We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation ...We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation scheme, and Agrawal model-based transmission line (TL) equations are organically integrated together. Specifically, the Agrawal model is employed to establish the TL equations to describe the coupling effects of space electromagnetic fields on transmission lines. Then, the excitation fields functioning as distribution sources in TL equations are calculated by the parallel FDTD method through using the message passing interface (MPI) library scheme and interpolation scheme. Finally, the TL equations are discretized by the central difference scheme of FDTD and assigned to multiple processors to obtain the transient responses on the terminal loads of these lines. The significant feature of the presented method is embodied in its parallel and synchronous calculations of the space electromagnetic fields and transient responses on the lines. Numerical simulations of ambient wave acting on multi-conductor transmission lines (MTLs), which are located on the PEC ground and in the shielded cavity respectively, are implemented to verify the accuracy and efficiency of the presented method.展开更多
A hybrid algorithm is presented for nonuniform lossy multiconductor transmission lines (MTL) connected by arbitrary linear load networks. The networks are characterized by a state-variable equation which allows a gene...A hybrid algorithm is presented for nonuniform lossy multiconductor transmission lines (MTL) connected by arbitrary linear load networks. The networks are characterized by a state-variable equation which allows a general characterization of dynamic elements in the cascade networks. The method is achieved by the finite difference-time domain (FDTD) algorithm for the MTL, and the skin effect is taken into account, the more accurate method is used to compute the skin effect. And this method is combined with the computation of the nonuniform transmission lines. Finally, several numerical examples are given, these results indicate that: the current of the lossy MTL is smaller than the lossless of the MTL; and when the load networks contain the dynamic element, the transition time of the current is longer than the MTL connected by resistance only.展开更多
The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, w...The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, which is based on right-handed nonlinear transmission lines and consists of a coplanar waveguide transmission line and periodically distributed GaAs planar Schottky varactor diode. The distributed-Schottky transmission-line-type phase shifter at a bias voltage greater than 1.5 V presents a continuous 0°–360° differential phase shift over a frequency range from 0 to 33 GHz. It is demonstrated that the minimum insertion loss is about 0.5 dB and that the return loss is less than-10 dB over the frequency band of 0–33 GHz at a reverse bias voltage less than 4.5 V. These excellent characteristics, such as broad differential phase shift, low insertion loss, and return loss, indicate that the proposed phase shifter can entirely be integrated into a phased array radar circuit.展开更多
This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is...This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is made possible by carefully adjusting the arrangements of each resonant cavity in a two-dimensional (2-D) slow wave structure. The high frequency characteristics are analyzed and a PIC simulation is carried out; the detailed results are discussed to get a better understanding of this new MILO. Employing an electron beam of about 441 kV and 39.7 kA, it finds that the modified HEM11 mode MILO generates a high power microwave output of about 1.47 GW at 1.45 GHz. The power conversion efficiency is about 8.4% and the generated microwave is in a TEll-like circularly polarized mode; its polarization direction is decided by the rotation direction of the SWS.展开更多
Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared...Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared with commonly used schemes involving dedicated devices or complicated techniques,a convenient approach for breakdown locating based on transmission line(TL)theory offers advantages in the typical constant-gradient TW-accelerating structure.To deliver such an approach,an equivalent TL model has been constructed to equate the TW-accelerating structure based on the fun-damental theory of the TL transient response in the time domain.An equivalence relationship between the TW-accelerating structure and the TL model has been established via analytical derivations associated with grid charts and verified by TL circuit simulations.Furthermore,to validate the proposed fault-locating method in practical applications,an elaborate analysis via such a method has been conducted for the recoverable RF-breakdown phenomena observed at an existing prototype of a TW-accelerating-structure-based beam injector constructed at the Huazhong University of Science and Technology.In addition,further considerations and discussion for extending the applications of the proposed method have been given.This breakdown-locating approach involving the transient response in the framework of TL theory can be a conceivable supple-ment to existing methods,facilitating solution to construction problems at an affordable cost.展开更多
The phenomenon of energy unidirectionM transmission is numerically investigated by using a system of two coupled discrete nonlinear electrical transmission lines, each line of the network contains a finite number of c...The phenomenon of energy unidirectionM transmission is numerically investigated by using a system of two coupled discrete nonlinear electrical transmission lines, each line of the network contains a finite number of cells and has different pass band structures, respectively. Using numerical simulations, we examine the frequency multiplication of the driving frequency and the lattice filtering effect in the line. These lead to the generation of energy unidirectional transmission. In the present work, energy is carried by the second harmonic wave in the pass band. In addition, we also study the dependence of the energy efficiency on the driving amplitude and other parameters of the model, such as the system size and the nonlinear coefficient, by calculation. Furthermore, after detailed numerical simulation, an experimental demonstration is realized. The experimental results agree with those in simulation qualitatively.展开更多
This paper proposes a simple scheme for realizing one-qubit and two-qubit quantum gates as well as multiqubit entanglement based on de-SQUID charge qubits through the control of their coupling to a 1D transmission lin...This paper proposes a simple scheme for realizing one-qubit and two-qubit quantum gates as well as multiqubit entanglement based on de-SQUID charge qubits through the control of their coupling to a 1D transmission line resonator (TLR). The TLR behaves effectively as a quantum data-bus mode of a harmonic oscillator, which has several practical advantages including strong coupling strength, reproducibility, immunity to 1/f noise, and suppressed spontaneous emission. In this protocol, the data-bus does not need to stay adiabatically in its ground state, which results in not only fast quantum operation, hut also high-fidelity quantum information processing. Also, it elaborates the transfer process with the 1D transmission line.展开更多
The nonlinear properties of lattice network-based(LNB) composite right-/left-handed transmission lines(CRLH TLs)with nonlinear capacitors are experimentally investigated.Harmonic generation,subharmonic generation,...The nonlinear properties of lattice network-based(LNB) composite right-/left-handed transmission lines(CRLH TLs)with nonlinear capacitors are experimentally investigated.Harmonic generation,subharmonic generation,and parametric excitation are clearly observed in an unbalanced LNB CRLH TL separately.While the balanced design of the novel nonlinear TL shows that the subharmonic generation and parametric processes can be suppressed,and almost the same power level of the higher harmonics can be achieved over a wide bandwidth range,which are difficult to find in conventional CRLH TLs.展开更多
Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit mo...Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.展开更多
Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covere...Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.展开更多
基金This work was supported by State Grid Science and Technology Project(B3440821K003).
文摘The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty lines.With the goal of achieving“carbon peak and carbon neutrality”,the schemes for clean energy generation have rapidly developed.Moreover,new energy-consuming equipment has been widely connected to the power grid,and the operating characteristics of the power system have significantly changed.Consequently,these have impacted traditional fault identification methods.Based on the time-frequency characteristics of the fault waveform,new energy-related parameters,and deep learning model,this study proposes a fault identification method suitable for scenarios where a high proportion of new energy is connected to the power grid.Ten parameters related to the causes of transmission line fault and new energy connection scenarios are selected as model characteristic parameters.Further,a fault identification model based on adaptive deep belief networks was constructed,and its effect was verified by field data.
基金Project supported by the China Postdoctoral Science Foundation(Grant No 20080431399)the National Natural Science Foundation of China (Grant No 60572135)
文摘This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT) equation, the time-domain analytic solutions are obtained and expressed in an infinite geometric series. Moreover, it is shown that there exist only finite nonzero terms in the infinite geometric series if the time variate is at a finite interval. In other word, the time-domain analytic solutions are expanded in a finite geometric series indeed if the time variate is at a finite interval. The computed results are subsequently compared with transient responses obtained by using the frequency-domain BLT equation via a fast Fourier transform, and the agreement is excellent.
基金supported by the Chinese National Natural Science Foundation (Grant No 10675168)Innovation Fund of Graduate School of the National University of Defense Technology of China
文摘An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.
基金financially supported by the National Key Research and Development Program(2017YFD0600101)the Central University Basic Research and Operating Expenses of Special Funding(2572016CB04)the Harbin Application Technology Research and Development Projects(2016RQQXJ134)
文摘Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding.
基金supported by National Natural Science Foundation of China(No.10905047)
文摘A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.
基金Project supported by the Science Foundation of Jiangsu Provincial Education 0ffice, China (Grant No 05KJD140035).
文摘On the basis of quantization of charge, the loop equations of quantum circuits are investigated by using the Helsenberg motion equation for a mesoscopic dissipation transmission line. On the supposition that the system has a symmetry under translation in charge space, the quantum current and the quantum energy spectrum in the mesoscopic transmission llne are given by solving their eigenvalue equations. Results show that the quantum current and the quantum energy spectrum are not only related to the parameters of the transmission llne, but also dependent on the quantized character of the charge obviously.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61231003 and 61201090)
文摘In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption of small rotation quantity, the factors affecting the induced voltage and their effects are analyzed and then an efficient method to calculate the average voltage is presented when the distribution of the random rotation angles is uniform in [-π, π]. The results show that voltage variation is mainly due to the change of the source term. The effects of the source term increase linearly with the magnitude of the incident wave, change periodically with the rotation angle, and are larger in the high frequency range than in the low frequency range. The results show that the average voltages obtained by the proposed method agree well with those via the Monte Carlo method and the proposed method is much more efficient. The results also imply that the effect of random rotation is more important than that of random translation.
基金supported by National High-tech Research and Development Program of China (863 Program) (2013AA030701)Science and Technology Project of the State Grid Xinjiang Electric Power Corporation (5230DK15009L)
文摘Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines.
基金supported by National Natural Science Foundation of China(Nos.51277061 and 51420105011)
文摘The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines.
基金Project supported by the Young Scientists Fund of the National Natural Science Foundation of China (Grant No. 60806024)the Fundamental Research Funds for Central Universities, China (Grant No. XDJK2009C020)the Singapore–China Joint Research Project (Grant No. 2009DFA12130)
文摘A fabrication technology of GaAs planar Schottky varactor diode (PSVD) is successfully developed and used to design and manufacture CaAs-based monolithic frequency multiplication based on 23-section nonlinear transmission lines (NLTLs) consisting of a coplanar waveguide transmission line and periodically distributed PSVDs. The throughout design and optimization procedure of 23-section monolithic NLTLs for frequency multiplication in the k-band range is based on a large signal equivalent model of PSVD extracted from small-signal S-parameter measurements. This paper reports that the distributed SPVD exhibits a capacitance ratio of 5.4, a normalized capacitance of 0.86 fF/μm2 and a breakdown voltage in excess of 22 V. The integrated 23-section NLTLs fed by 20-dBm input power demonstrates a 26-GHz peak second harmonic output power of 14-dBm with 25.3% conversion efficiency in the second harmonic output frequency range of 6 GHz-26 GHz.
基金Project supported by the National Natural Science Foundation of China(Grant No.61701057)the Chongqing Research Program of Basic Research and Frontier Technology,China(Grant No.cstc2017jcyjAX0345).
文摘We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation scheme, and Agrawal model-based transmission line (TL) equations are organically integrated together. Specifically, the Agrawal model is employed to establish the TL equations to describe the coupling effects of space electromagnetic fields on transmission lines. Then, the excitation fields functioning as distribution sources in TL equations are calculated by the parallel FDTD method through using the message passing interface (MPI) library scheme and interpolation scheme. Finally, the TL equations are discretized by the central difference scheme of FDTD and assigned to multiple processors to obtain the transient responses on the terminal loads of these lines. The significant feature of the presented method is embodied in its parallel and synchronous calculations of the space electromagnetic fields and transient responses on the lines. Numerical simulations of ambient wave acting on multi-conductor transmission lines (MTLs), which are located on the PEC ground and in the shielded cavity respectively, are implemented to verify the accuracy and efficiency of the presented method.
文摘A hybrid algorithm is presented for nonuniform lossy multiconductor transmission lines (MTL) connected by arbitrary linear load networks. The networks are characterized by a state-variable equation which allows a general characterization of dynamic elements in the cascade networks. The method is achieved by the finite difference-time domain (FDTD) algorithm for the MTL, and the skin effect is taken into account, the more accurate method is used to compute the skin effect. And this method is combined with the computation of the nonuniform transmission lines. Finally, several numerical examples are given, these results indicate that: the current of the lossy MTL is smaller than the lossless of the MTL; and when the load networks contain the dynamic element, the transition time of the current is longer than the MTL connected by resistance only.
基金Project supported by the Fundamental Research Funds for Central Universities,China(Grant No.XDJK2013B004)the Research Fund for the Doctoral Program of Southwest University,China(Grant No.SWU111030)the State Key Laboratory for Millimeter Waves of Southeast University,China(Grant No.K201312)
文摘The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, which is based on right-handed nonlinear transmission lines and consists of a coplanar waveguide transmission line and periodically distributed GaAs planar Schottky varactor diode. The distributed-Schottky transmission-line-type phase shifter at a bias voltage greater than 1.5 V presents a continuous 0°–360° differential phase shift over a frequency range from 0 to 33 GHz. It is demonstrated that the minimum insertion loss is about 0.5 dB and that the return loss is less than-10 dB over the frequency band of 0–33 GHz at a reverse bias voltage less than 4.5 V. These excellent characteristics, such as broad differential phase shift, low insertion loss, and return loss, indicate that the proposed phase shifter can entirely be integrated into a phased array radar circuit.
基金Project supported by the Science Foundation of the China Academy of Engineering Physics (Grant No 2008B0402046)
文摘This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is made possible by carefully adjusting the arrangements of each resonant cavity in a two-dimensional (2-D) slow wave structure. The high frequency characteristics are analyzed and a PIC simulation is carried out; the detailed results are discussed to get a better understanding of this new MILO. Employing an electron beam of about 441 kV and 39.7 kA, it finds that the modified HEM11 mode MILO generates a high power microwave output of about 1.47 GW at 1.45 GHz. The power conversion efficiency is about 8.4% and the generated microwave is in a TEll-like circularly polarized mode; its polarization direction is decided by the rotation direction of the SWS.
基金supported by the National Natural Science Foundation of China(No.11905074).
文摘Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared with commonly used schemes involving dedicated devices or complicated techniques,a convenient approach for breakdown locating based on transmission line(TL)theory offers advantages in the typical constant-gradient TW-accelerating structure.To deliver such an approach,an equivalent TL model has been constructed to equate the TW-accelerating structure based on the fun-damental theory of the TL transient response in the time domain.An equivalence relationship between the TW-accelerating structure and the TL model has been established via analytical derivations associated with grid charts and verified by TL circuit simulations.Furthermore,to validate the proposed fault-locating method in practical applications,an elaborate analysis via such a method has been conducted for the recoverable RF-breakdown phenomena observed at an existing prototype of a TW-accelerating-structure-based beam injector constructed at the Huazhong University of Science and Technology.In addition,further considerations and discussion for extending the applications of the proposed method have been given.This breakdown-locating approach involving the transient response in the framework of TL theory can be a conceivable supple-ment to existing methods,facilitating solution to construction problems at an affordable cost.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10974095 and 10774072)
文摘The phenomenon of energy unidirectionM transmission is numerically investigated by using a system of two coupled discrete nonlinear electrical transmission lines, each line of the network contains a finite number of cells and has different pass band structures, respectively. Using numerical simulations, we examine the frequency multiplication of the driving frequency and the lattice filtering effect in the line. These lead to the generation of energy unidirectional transmission. In the present work, energy is carried by the second harmonic wave in the pass band. In addition, we also study the dependence of the energy efficiency on the driving amplitude and other parameters of the model, such as the system size and the nonlinear coefficient, by calculation. Furthermore, after detailed numerical simulation, an experimental demonstration is realized. The experimental results agree with those in simulation qualitatively.
基金supported by Hunan Provincial Natural Science Foundation of China (Grant No 06JJ50014)the Key Project Foundation of the Education Commission of Hunan Province of China (Grant No 06A055)
文摘This paper proposes a simple scheme for realizing one-qubit and two-qubit quantum gates as well as multiqubit entanglement based on de-SQUID charge qubits through the control of their coupling to a 1D transmission line resonator (TLR). The TLR behaves effectively as a quantum data-bus mode of a harmonic oscillator, which has several practical advantages including strong coupling strength, reproducibility, immunity to 1/f noise, and suppressed spontaneous emission. In this protocol, the data-bus does not need to stay adiabatically in its ground state, which results in not only fast quantum operation, hut also high-fidelity quantum information processing. Also, it elaborates the transfer process with the 1D transmission line.
基金supported by the National Natural Science Foundation of China(Grant Nos.61201030,60990322,and 60990320)the China Postdoctoral Science Foundation(Grant No.2012M521048)the Collegiate Natural Science Fund of Jiangsu Province,China(Grant No.12KJB140010)
文摘The nonlinear properties of lattice network-based(LNB) composite right-/left-handed transmission lines(CRLH TLs)with nonlinear capacitors are experimentally investigated.Harmonic generation,subharmonic generation,and parametric excitation are clearly observed in an unbalanced LNB CRLH TL separately.While the balanced design of the novel nonlinear TL shows that the subharmonic generation and parametric processes can be suppressed,and almost the same power level of the higher harmonics can be achieved over a wide bandwidth range,which are difficult to find in conventional CRLH TLs.
基金supported by National Natural Science Foundation of China(Nos.51307141,51077111)by the State Key Laboratory Foundational Research Funds of China(Nos.SKLIPR1302Z,SKLIPR1306)
文摘Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.
基金by State Grid Shandong Electric Power Company(52062618001M)。
文摘Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.