期刊文献+

Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines 被引量:1

Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines
在线阅读 下载PDF
导出
摘要 The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第6期475-480,共6页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(Nos.51277061 and 51420105011)
关键词 AC transmission lines secondary arc arcing time dynamic modeling criticallength criterion AC transmission lines; secondary arc; arcing time; dynamic modeling; criticallength criterion
作者简介 E-mail address of CONG Haoxi: conghaoxi@163.com
  • 相关文献

参考文献22

  • 1Samorodov G, Krasilnikova T, Dikoy V, et al. 2002, Nonconventional reliable AC transmission systems for power delivery at long and very long distance. IEEE/PES Transmission and Distribution Conference and Exhibition, Yokohama.
  • 2Santos G, Tozzi C, Tavares M C, et al. 2011, IEEE Trans. Dielectr. Electr. Insul., 18:200.
  • 3Dos Santos M L, Jardini J A, Casolari R P. 2014, IEEE Trans. Power Del., 29:502.
  • 4Yatsenko R, Samorodov G, Krasilnikova T, et al. 2002, Economic and reliable electric tie for energy export from South-Yakutia Hydro power complex to Korea. Proceedings of the 6th Russian-Korean International Symposium on Science and Technology, Tokyo.
  • 5Prabhakara F S, Prathasarathy K, Ramachandra Rao H N. 1969, IEEE Trans. Power App. Syst., 88:1787.
  • 6Tsuboi T, Takami J, Okabe S, et al. 2013, IEEE Trans. Dieleetr. Eleetr. Insul., 20:2277.
  • 7Xu Z Y, Zhang X, Yan X Q, et al. 2012, IET Gener. Transm. Distrib., 6:1235.
  • 8Virginie I, Daniel S, Jean C M V. 2008, IEEE Trans. Plasma Sei., 36:2404.
  • 9Li Q M, Cong H X, Sun Q Q, et al. 2014, IEEE Trans. Power Del., 29:2324.
  • 10Cu S Q, He J L, Zhang B, et al. 2006, IEEE Trans. Magn., 42:1359.

同被引文献12

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部