Adopting "simultaneous transmitting, simultaneous receiving" operational scheme, instantaneous polarization radar (IPR) can measure target polarization scattering matrix (PSM) using only once target echoes in tw...Adopting "simultaneous transmitting, simultaneous receiving" operational scheme, instantaneous polarization radar (IPR) can measure target polarization scattering matrix (PSM) using only once target echoes in two orthogonal polarization channels. Firstly, signal model and signal process are advanced under narrowband condition. Secondly, measurement performances of two typical IPR waveforms are analyzed in detail. At last, field experiments are carried out using X-band IPR system designed by National University of Defense Technology (NUDT), China. Compared with results obtained by alternative polarization measurement scheme, following results can be obtained: the difference of relative amplitude measurement results is smaller than 2 dB and that of relative phase measurement results is smaller than 10?, verifying the validity of instantaneous polarization measurement scheme.展开更多
A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarizati...A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect.展开更多
Usually the polarization of the interference and the target backscattering may vary constantly, so the optimal receiving polarization of the polarization filter should be recalculated, which makes the filter realizati...Usually the polarization of the interference and the target backscattering may vary constantly, so the optimal receiving polarization of the polarization filter should be recalculated, which makes the filter realization very difficult. Also the predict method of the necessary parameters is not explained in most papers, which makes the polarization filter realization impossible. A novel modi- fied interference suppression (MIS) polarization filter is proposed, which resolves these problems by a new polarization designed strategy. The computation of this polarization filter is easy in most conditions, and the necessary parameters estimation method in real time is introduced, which makes polarization filter design possible.展开更多
基金supported by the National Natural Science Foundationof China (60736006 60802078)
文摘Adopting "simultaneous transmitting, simultaneous receiving" operational scheme, instantaneous polarization radar (IPR) can measure target polarization scattering matrix (PSM) using only once target echoes in two orthogonal polarization channels. Firstly, signal model and signal process are advanced under narrowband condition. Secondly, measurement performances of two typical IPR waveforms are analyzed in detail. At last, field experiments are carried out using X-band IPR system designed by National University of Defense Technology (NUDT), China. Compared with results obtained by alternative polarization measurement scheme, following results can be obtained: the difference of relative amplitude measurement results is smaller than 2 dB and that of relative phase measurement results is smaller than 10?, verifying the validity of instantaneous polarization measurement scheme.
基金supported by the National Natural Science Priority Foundation of China(60736006)National Natural Science Foundation of China for Youth(60802078)+1 种基金National Basic Research Program(973 Program)(51314)Hunan Provincial Innovation Foundation for Postgraduate
文摘A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect.
基金supported by the National Natural Science Foundation of China (60736001)
文摘Usually the polarization of the interference and the target backscattering may vary constantly, so the optimal receiving polarization of the polarization filter should be recalculated, which makes the filter realization very difficult. Also the predict method of the necessary parameters is not explained in most papers, which makes the polarization filter realization impossible. A novel modi- fied interference suppression (MIS) polarization filter is proposed, which resolves these problems by a new polarization designed strategy. The computation of this polarization filter is easy in most conditions, and the necessary parameters estimation method in real time is introduced, which makes polarization filter design possible.