We introduce first a sort of gray-scale morphological dilations and erosions, which might have some further applications in image analysis. Then we show that the dilation and the erosion defined here form adjunctive p...We introduce first a sort of gray-scale morphological dilations and erosions, which might have some further applications in image analysis. Then we show that the dilation and the erosion defined here form adjunctive pairs. The duality between the dilation and the erosion and some other properties, such as homothety, of these operators are discussed the Commuting property with translation and as well.展开更多
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana...BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care.展开更多
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diamet...BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access.METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey’s post-hoc analysis were used for multiple comparisons.RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75% and 50% of its original diameter increased arterial pulsation.CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.展开更多
In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation pr...In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment.展开更多
Handheld ultrasound devices are known for their portability and affordability,making them widely utilized in underdeveloped areas and community healthcare for rapid diagnosis and early screening.However,the image qual...Handheld ultrasound devices are known for their portability and affordability,making them widely utilized in underdeveloped areas and community healthcare for rapid diagnosis and early screening.However,the image quality of handheld ultrasound devices is not always satisfactory due to the limited equipment size,which hinders accurate diagnoses by doctors.At the same time,paired ultrasound images are difficult to obtain from the clinic because imaging process is complicated.Therefore,we propose a modified cycle generative adversarial network(cycleGAN) for ultrasound image enhancement from multiple organs via unpaired pre-training.We introduce an ultrasound image pre-training method that does not require paired images,alleviating the requirement for large-scale paired datasets.We also propose an enhanced block with different structures in the pre-training and fine-tuning phases,which can help achieve the goals of different training phases.To improve the robustness of the model,we add Gaussian noise to the training images as data augmentation.Our approach is effective in obtaining the best quantitative evaluation results using a small number of parameters and less training costs to improve the quality of handheld ultrasound devices.展开更多
基金Supported by the National Natural Science Foundation of China(11671293, 11271282)
文摘We introduce first a sort of gray-scale morphological dilations and erosions, which might have some further applications in image analysis. Then we show that the dilation and the erosion defined here form adjunctive pairs. The duality between the dilation and the erosion and some other properties, such as homothety, of these operators are discussed the Commuting property with translation and as well.
文摘BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care.
基金supported by the Department of Advanced Acute Medicine at Nagoya City University.
文摘BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access.METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey’s post-hoc analysis were used for multiple comparisons.RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75% and 50% of its original diameter increased arterial pulsation.CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
基金National Natural Science Foundation of China(Grant Nos.51821003,52175524,61704158)the Natural Science Foundation of Shanxi Province(Grant No.202103021224206)Shanxi"1331 Project"Key Subjects Construction to provide fund for conducting experiments。
文摘In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment.
文摘Handheld ultrasound devices are known for their portability and affordability,making them widely utilized in underdeveloped areas and community healthcare for rapid diagnosis and early screening.However,the image quality of handheld ultrasound devices is not always satisfactory due to the limited equipment size,which hinders accurate diagnoses by doctors.At the same time,paired ultrasound images are difficult to obtain from the clinic because imaging process is complicated.Therefore,we propose a modified cycle generative adversarial network(cycleGAN) for ultrasound image enhancement from multiple organs via unpaired pre-training.We introduce an ultrasound image pre-training method that does not require paired images,alleviating the requirement for large-scale paired datasets.We also propose an enhanced block with different structures in the pre-training and fine-tuning phases,which can help achieve the goals of different training phases.To improve the robustness of the model,we add Gaussian noise to the training images as data augmentation.Our approach is effective in obtaining the best quantitative evaluation results using a small number of parameters and less training costs to improve the quality of handheld ultrasound devices.