In order to examine the factors which affect the range of heat transfer in earth surrounding subways, FLAC3D was adopted in this study to analyze these factors, under different conditions, in a systematic manner. When...In order to examine the factors which affect the range of heat transfer in earth surrounding subways, FLAC3D was adopted in this study to analyze these factors, under different conditions, in a systematic manner. When we compare these numerical tests, the results show that the main factors, affecting the heat transfer range are the thermal properties of the surrounding earth, the initial ground temperature and the temperature in the tunnel. The heat transfer coefficient between air and linings has little effect on the temperature distribution around the tunnel. The current results can provide a reference for improving the thermal environment in subways and optimizing the design of subwav ventilation and air conditioning.展开更多
Finite and infinite coupled element method was used to analyze the strength and deformation in layered soil foundation which was under the rectangular shallow footing subjected to vertical loads. In the numerical anal...Finite and infinite coupled element method was used to analyze the strength and deformation in layered soil foundation which was under the rectangular shallow footing subjected to vertical loads. In the numerical analysis, the footing was assumed to be elastic; the soil was assumed to be elastoplastic and the Drucker-Prager constitutive model was applied to describe its mechanic behavior. Corresponding program was employed to compute six kinds of layered soil foundations constituted by different soil layers. The conclusions which are useful in the theory and practice were made according to the analysis of the computation results.展开更多
基金Projects BK2007145 supported by the Jiangsu Natural Science Foundation of China NCET-04-0454 by the Program for New Century Excellent Talentsin Universities
文摘In order to examine the factors which affect the range of heat transfer in earth surrounding subways, FLAC3D was adopted in this study to analyze these factors, under different conditions, in a systematic manner. When we compare these numerical tests, the results show that the main factors, affecting the heat transfer range are the thermal properties of the surrounding earth, the initial ground temperature and the temperature in the tunnel. The heat transfer coefficient between air and linings has little effect on the temperature distribution around the tunnel. The current results can provide a reference for improving the thermal environment in subways and optimizing the design of subwav ventilation and air conditioning.
基金Funded by Communication Construction Scientific Research Programme of the Western Region of China from the Communications Ministry of China (No.2002-318-000-26)
文摘Finite and infinite coupled element method was used to analyze the strength and deformation in layered soil foundation which was under the rectangular shallow footing subjected to vertical loads. In the numerical analysis, the footing was assumed to be elastic; the soil was assumed to be elastoplastic and the Drucker-Prager constitutive model was applied to describe its mechanic behavior. Corresponding program was employed to compute six kinds of layered soil foundations constituted by different soil layers. The conclusions which are useful in the theory and practice were made according to the analysis of the computation results.