The aim of this study is to address the issues associated with traditional magnetorheological fluid(MRF)dampers,such as insufficient damping force after power failure and susceptibility to settlement.In order to achie...The aim of this study is to address the issues associated with traditional magnetorheological fluid(MRF)dampers,such as insufficient damping force after power failure and susceptibility to settlement.In order to achieve this,a bidirectional adjustable MRF damper was designed and developed.Magnetic field simulation analysis was conducted on the damper,along with simulation analysis on its dynamic characteristics.The dynamic characteristics were ultimately validated through experimental testing on the material testing machine,thereby corroborating the theoretical simulation results.Concurrently,this process generated valuable test data for subsequent implementation of the semi-active vibration control system.The simulation and test results demonstrate that the integrated permanent magnet effectively accomplishes bidirectional regulation.The magnetic induction intensity of the damping channel is 0.2 T in the absence of current,increases to 0.5 T when a maximum forward current of 4 A is applied,and becomes 0 T when a maximum reverse current of 3.8 A is applied.When the excitation amplitude is 8 mm and the frequency is 2 Hz,with the applied currents varying,the maximum damping force reaches 8 kN,while the minimum damping force measures at 511 N.Additionally,at zero current,the damping force stands at 2 kN,which aligns closely with simulation results.The present paper can serve as a valuable reference for the design and research of semi-active MRF dampers.展开更多
Inspired by the thermal stability mechanism of thermophilic protein,which presents ionic bonds that have better stability at higher temperatures,this paper proposes the introduction of electrostatic interactions by ad...Inspired by the thermal stability mechanism of thermophilic protein,which presents ionic bonds that have better stability at higher temperatures,this paper proposes the introduction of electrostatic interactions by adding carboxyl-modified silica(C-SiO2),PAA,and CaCl_(2) to achieve higher viscosity over 25℃.The rheological behavior of C-SiO_(2)-based shear thickening fluid(CS-STF)was investigated at a temperature range of 25–55℃.Unlike SiO_(2)-based STF,which exhibits single-step thickening and a negative correlation between viscosity and temperature.As the C-SiO_(2) content was 41%(w/w)and the mass ratio of PAA:CaCl_(2):C-SiO_(2) was 3:1:10,the CS-STF displayed a double-thickening behavior,and the peak viscosity reached 1330 Pa·s at 35℃.From the yarn pull-out test,the inter-yarn force was significantly increased with the increasing CS-STF content.Treating UHMWPE fabrics with CS-STF improved the impact resistance effectively.In the blunt impact test,the U-CS fabrics with high CS-STF content(121.45 wt%)experienced penetration failure under high impact energy(18 J)due to stress concentration caused by the shear thickening behavior.The knife stabbing test demonstrated that U-CS fabrics with appropriate content(88.38 wt%)have the best stabbing resistance in various impact energies.Overall,this study proposed a high-performence STF showing double-thickening and enhancing shear-thickening behavior at a wide temperature range,the composite fabrics with the performance of resisting both the blunt and stab impact had broad application prospects in the field of personal protection.展开更多
VOF(Volume of Fluid)方法由于其良好的守恒性和网格适应性,且具有计算资源需求相对较小等优点,成为船舶水动力学领域自由面流动CFD(Computational Fluid Dynamics)模拟的主流方法。但原始的VOF方法存在较为严重的界面扩散问题,导致模...VOF(Volume of Fluid)方法由于其良好的守恒性和网格适应性,且具有计算资源需求相对较小等优点,成为船舶水动力学领域自由面流动CFD(Computational Fluid Dynamics)模拟的主流方法。但原始的VOF方法存在较为严重的界面扩散问题,导致模拟的界面厚度过大、空间分辨率不够,进而影响流场相关变量的计算精度,这一问题在非定常自由面流动模拟中尤为明显。本文针对上述问题,通过在VOF控制方程中引入人工对流项以达到抑制界面扩散、压缩界面厚度的目的,并采用隐式离散人工对流项的方式提高计算稳定性,形成了反扩散VOF算法。经Zalesak和剪切场等经典算例在不同数量网格下的测试验证,表明反扩散VOF算法能够大幅压缩界面厚度,同时明显减小质量误差。随后的三维无障碍溃坝算例和破舱进水算例,进一步证明了反扩散VOF算法在实际非定常流动模拟中能够更好地捕捉自由面并提高计算精度。展开更多
Exosomes,ubiquitously present in body fluids,serve as non-invasive biomarkers for disease diagnosis,monitoring,and treatment.As intercellular messengers,exosomes encapsulate a rich array of proteins,nucleic acids,and ...Exosomes,ubiquitously present in body fluids,serve as non-invasive biomarkers for disease diagnosis,monitoring,and treatment.As intercellular messengers,exosomes encapsulate a rich array of proteins,nucleic acids,and metabolites,although most studies have primarily focused on proteins and RNA.Recently,exosome metabolomics has demonstrated clinical value and potential advantages in disease detection and pathophysiology,despite significant challenges,particularly in exosome isolation and metabolite detection.This review discusses the significant technical challenges in exosome isolation and metabolite detection,highlighting the advancements in these areas that support the clinical application of exosome metabolomics,and illustrates the potential of exosomal metabolites from various body fluids as biomarkers for early disease diagnosis and treatment.展开更多
Infrared microthermometry allows direct measurement of fluid inclusions hosted in opaque ore minerals and can provide direct constraints on the evolution of ore-forming fluids.This study presents infrared microthermom...Infrared microthermometry allows direct measurement of fluid inclusions hosted in opaque ore minerals and can provide direct constraints on the evolution of ore-forming fluids.This study presents infrared microthermometry of spherite-hosted fluid inclusions from the Xinqiao deposit in the Middle-Lower Yangtze Metallogenic Belt and sheds new light on the ore genesis of the deposit.Considering that infrared light may lead to non-negligible temperature deviations during microthermometry,some tests were first conducted to ensure the accuracy of the microthermometric measurements.The measurement results indicated that using the lowest light intensity of the microscope and inserting an optical filter were effective in minimizing the possible temperature deviations of infrared microthermometry.All sphalerite-hosted fluid inclusions from the Xinqiao deposit were aqueous.They show homogenization temperature ranging from~200 to 350℃,but have two separate salinity groups(1.0 wt%-10 wt%and 15.1 wt%-19.2 wt%NaCl equivalent).The low-salinity group represents sedimentary exhalative(SEDEX)-associated fluids,whereas the high-salinity group results from modification by later magmatic hydrothermal fluids.Combined with published fluid inclusion data,the four-stage fluid evolution of the Xinqiao deposit was depicted.Furthermore,our data suggest that the Xinqiao deposit was formed by twostage metallogenic events including SEDEX and magmatic-hydrothermal mineralization.展开更多
Fatigue and tensile behaviors of homogenized WE 54 magnesium alloy before and after immersion in simulated body fluid(SBF)were investigated.According to the tensile test,the alloy without immersion in SBF solution has...Fatigue and tensile behaviors of homogenized WE 54 magnesium alloy before and after immersion in simulated body fluid(SBF)were investigated.According to the tensile test,the alloy without immersion in SBF solution has the highest tensile strength of 278 MPa,which decreased to 190 MPa after 336 h of immersion..The fatigue life of the homogenized WE 54 magnesium alloy before immersion in the SBF solution under a constant stress of 15 MPa is 3598 cycles.However,the fatigue life of the alloy decreased to 453 cycles after 336 h of immersion in the SBF solution under the same stress.Examination of the fracture surface of the samples by SEM reveals that the origin of the fatigue crack before immersion is micro-pores and defects.While corrosion pits and cracks are the main reasons for forming the initial fatigue crack after immersion.Moreover,the results obtained from practical work were evaluated and compared to theoretical calculations.The area of the hysteresis loops of the samples after the fatigue test,determined using Triangles and Monte Carlo methods,decreased from 4954.5 MPa and 4842.9 MPa before immersion to 192.0 MPa and 175.8 MPa after 336 h of immersion,respectively.展开更多
文摘The aim of this study is to address the issues associated with traditional magnetorheological fluid(MRF)dampers,such as insufficient damping force after power failure and susceptibility to settlement.In order to achieve this,a bidirectional adjustable MRF damper was designed and developed.Magnetic field simulation analysis was conducted on the damper,along with simulation analysis on its dynamic characteristics.The dynamic characteristics were ultimately validated through experimental testing on the material testing machine,thereby corroborating the theoretical simulation results.Concurrently,this process generated valuable test data for subsequent implementation of the semi-active vibration control system.The simulation and test results demonstrate that the integrated permanent magnet effectively accomplishes bidirectional regulation.The magnetic induction intensity of the damping channel is 0.2 T in the absence of current,increases to 0.5 T when a maximum forward current of 4 A is applied,and becomes 0 T when a maximum reverse current of 3.8 A is applied.When the excitation amplitude is 8 mm and the frequency is 2 Hz,with the applied currents varying,the maximum damping force reaches 8 kN,while the minimum damping force measures at 511 N.Additionally,at zero current,the damping force stands at 2 kN,which aligns closely with simulation results.The present paper can serve as a valuable reference for the design and research of semi-active MRF dampers.
基金the Major Science and Technology Demonstration Projects in Jiangsu Province(Grant No.BE2022608).
文摘Inspired by the thermal stability mechanism of thermophilic protein,which presents ionic bonds that have better stability at higher temperatures,this paper proposes the introduction of electrostatic interactions by adding carboxyl-modified silica(C-SiO2),PAA,and CaCl_(2) to achieve higher viscosity over 25℃.The rheological behavior of C-SiO_(2)-based shear thickening fluid(CS-STF)was investigated at a temperature range of 25–55℃.Unlike SiO_(2)-based STF,which exhibits single-step thickening and a negative correlation between viscosity and temperature.As the C-SiO_(2) content was 41%(w/w)and the mass ratio of PAA:CaCl_(2):C-SiO_(2) was 3:1:10,the CS-STF displayed a double-thickening behavior,and the peak viscosity reached 1330 Pa·s at 35℃.From the yarn pull-out test,the inter-yarn force was significantly increased with the increasing CS-STF content.Treating UHMWPE fabrics with CS-STF improved the impact resistance effectively.In the blunt impact test,the U-CS fabrics with high CS-STF content(121.45 wt%)experienced penetration failure under high impact energy(18 J)due to stress concentration caused by the shear thickening behavior.The knife stabbing test demonstrated that U-CS fabrics with appropriate content(88.38 wt%)have the best stabbing resistance in various impact energies.Overall,this study proposed a high-performence STF showing double-thickening and enhancing shear-thickening behavior at a wide temperature range,the composite fabrics with the performance of resisting both the blunt and stab impact had broad application prospects in the field of personal protection.
文摘VOF(Volume of Fluid)方法由于其良好的守恒性和网格适应性,且具有计算资源需求相对较小等优点,成为船舶水动力学领域自由面流动CFD(Computational Fluid Dynamics)模拟的主流方法。但原始的VOF方法存在较为严重的界面扩散问题,导致模拟的界面厚度过大、空间分辨率不够,进而影响流场相关变量的计算精度,这一问题在非定常自由面流动模拟中尤为明显。本文针对上述问题,通过在VOF控制方程中引入人工对流项以达到抑制界面扩散、压缩界面厚度的目的,并采用隐式离散人工对流项的方式提高计算稳定性,形成了反扩散VOF算法。经Zalesak和剪切场等经典算例在不同数量网格下的测试验证,表明反扩散VOF算法能够大幅压缩界面厚度,同时明显减小质量误差。随后的三维无障碍溃坝算例和破舱进水算例,进一步证明了反扩散VOF算法在实际非定常流动模拟中能够更好地捕捉自由面并提高计算精度。
文摘Exosomes,ubiquitously present in body fluids,serve as non-invasive biomarkers for disease diagnosis,monitoring,and treatment.As intercellular messengers,exosomes encapsulate a rich array of proteins,nucleic acids,and metabolites,although most studies have primarily focused on proteins and RNA.Recently,exosome metabolomics has demonstrated clinical value and potential advantages in disease detection and pathophysiology,despite significant challenges,particularly in exosome isolation and metabolite detection.This review discusses the significant technical challenges in exosome isolation and metabolite detection,highlighting the advancements in these areas that support the clinical application of exosome metabolomics,and illustrates the potential of exosomal metabolites from various body fluids as biomarkers for early disease diagnosis and treatment.
基金supported by the National Key R&D Program of China(2018YFA0702701)the Fundamental Research Funds for the Central Universities(WK3410000015).
文摘Infrared microthermometry allows direct measurement of fluid inclusions hosted in opaque ore minerals and can provide direct constraints on the evolution of ore-forming fluids.This study presents infrared microthermometry of spherite-hosted fluid inclusions from the Xinqiao deposit in the Middle-Lower Yangtze Metallogenic Belt and sheds new light on the ore genesis of the deposit.Considering that infrared light may lead to non-negligible temperature deviations during microthermometry,some tests were first conducted to ensure the accuracy of the microthermometric measurements.The measurement results indicated that using the lowest light intensity of the microscope and inserting an optical filter were effective in minimizing the possible temperature deviations of infrared microthermometry.All sphalerite-hosted fluid inclusions from the Xinqiao deposit were aqueous.They show homogenization temperature ranging from~200 to 350℃,but have two separate salinity groups(1.0 wt%-10 wt%and 15.1 wt%-19.2 wt%NaCl equivalent).The low-salinity group represents sedimentary exhalative(SEDEX)-associated fluids,whereas the high-salinity group results from modification by later magmatic hydrothermal fluids.Combined with published fluid inclusion data,the four-stage fluid evolution of the Xinqiao deposit was depicted.Furthermore,our data suggest that the Xinqiao deposit was formed by twostage metallogenic events including SEDEX and magmatic-hydrothermal mineralization.
文摘Fatigue and tensile behaviors of homogenized WE 54 magnesium alloy before and after immersion in simulated body fluid(SBF)were investigated.According to the tensile test,the alloy without immersion in SBF solution has the highest tensile strength of 278 MPa,which decreased to 190 MPa after 336 h of immersion..The fatigue life of the homogenized WE 54 magnesium alloy before immersion in the SBF solution under a constant stress of 15 MPa is 3598 cycles.However,the fatigue life of the alloy decreased to 453 cycles after 336 h of immersion in the SBF solution under the same stress.Examination of the fracture surface of the samples by SEM reveals that the origin of the fatigue crack before immersion is micro-pores and defects.While corrosion pits and cracks are the main reasons for forming the initial fatigue crack after immersion.Moreover,the results obtained from practical work were evaluated and compared to theoretical calculations.The area of the hysteresis loops of the samples after the fatigue test,determined using Triangles and Monte Carlo methods,decreased from 4954.5 MPa and 4842.9 MPa before immersion to 192.0 MPa and 175.8 MPa after 336 h of immersion,respectively.