A novel shrouded wind-solar hybrid renewable energy and rain water harvester with an omni-directional-guide-vane(ODGV) for urban high-rise application is introduced.The ODGV surrounds the vertical axis wind turbine(VA...A novel shrouded wind-solar hybrid renewable energy and rain water harvester with an omni-directional-guide-vane(ODGV) for urban high-rise application is introduced.The ODGV surrounds the vertical axis wind turbine(VAWT) and enhances the VAWT performance by increasing the on-coming wind speed and guiding it to an optimum flow angle before it interacts with the rotor blades.An ODGV scaled model was built and tested in the laboratory.The experimental results show that the rotational speed of the VAWT increases by about 2 times.Simulations show that the installation of the ODGV increases the torque output of a single-bladed VAWT by 206% for tip speed ratio of 0.4.The result also reveals that higher positive torque can be achieved when the blade tangential force at all radial positions is optimized.In conclusion,the ODGV improves the power output of a VAWT and this integrated design promotes the installation of wind energy systems in urban areas.展开更多
Wind energy is one of the most promising renewable energy sources, straight-bladed vertical axis wind turbine(S-VAWT) appears to be particularly promising for the shortage of fossil fuel reserves owing to its distinct...Wind energy is one of the most promising renewable energy sources, straight-bladed vertical axis wind turbine(S-VAWT) appears to be particularly promising for the shortage of fossil fuel reserves owing to its distinct advantages, but suffers from poor self-starting and low power coefficient. Variable-pitch method was recognized as an attractive solution to performance improvement, thus majority efforts had been devoted into blade pitch angle effect on aerodynamic performance. Taken into account the local flow field of S-VAWT, mathematical model was built to analyze the relationship between power outputs and pitch angle. Numerical simulations on static and dynamic performances of blade were carried out and optimized pitch angle along the rotor were presented. Comparative analyses of fixed pitch and variable-pitch S-VAWT were conducted, and a considerable improvement of the performance was obtained by the optimized blade pitch angle, in particular, a relative increase of the power coefficient by more than 19.3%. It is further demonstrated that the self-starting is greatly improved with the optimized blade pitch angle.展开更多
In this study,wind tunnel experiment was carried out to investigate the self-staring capability for straight-bladed vertical axis wind turbine.The flow visualization also was been performed at the rest of the rotor.Th...In this study,wind tunnel experiment was carried out to investigate the self-staring capability for straight-bladed vertical axis wind turbine.The flow visualization also was been performed at the rest of the rotor.The effect of the azimuthal angle of blade position relative to wind direction on the self-starting capability was discussed based on the results of flow visualization.The torque and centripetal force of the rotor when the self-starting behavior starts were roughly calculated with the flow visualization results of the rotor.It is suggested that there exists the condition of wind speed and configuration of the blade position of the rotor at the rest of rotor to the reach to situational rotation number.展开更多
The finite element analysis was carried out for a composite vertical axis wind turbine with lift-drag combined starting structures to ensure the structure safety of a vertical axis wind turbine(VAWT).The static and mo...The finite element analysis was carried out for a composite vertical axis wind turbine with lift-drag combined starting structures to ensure the structure safety of a vertical axis wind turbine(VAWT).The static and modal analysis of rotor of a composite vertical axis wind turbine was conducted by using ANSYS software.The relevant contour sketch of stress and deformation was obtained.The analysis was made for static structural mechanics,modal analysis of rotor and the total deformation and vibration profile to evaluate the influence on the working capability of the rotor.The analysis results show that the various structure parameters lie in the safety range of structural mechanics in the relative standards.The analysis showing the design safe to operate the rotor of a vertical axis wind turbine.The methods used in this study can be used as a good reference for the structural mechanics′analysis of VAWTs.展开更多
Collective pitch control and individual pitch control algorithms were present for straight-bladed vertical axis wind turbine to improve the self-starting capacity.Comparative analysis of straight-bladed vertical axis ...Collective pitch control and individual pitch control algorithms were present for straight-bladed vertical axis wind turbine to improve the self-starting capacity.Comparative analysis of straight-bladed vertical axis wind turbine(SB-VAWT)with or without pitch control was conducted from the aspects of aerodynamic force,flow structure and power coefficient.The computational fluid dynamics(CFD)prediction results show a significant increase in power coefficient for SB-VAWT with pitch control.According to the aerodynamic forces and total torque coefficient obtained at various tip speed ratios(TSRs),the results indicate that the blade pitch method can increase the power output and decrease the deformation of blade;especially,the total torque coefficient of blade pitch control at TSR 1.5 is about 2.5 times larger than that of fixed pitch case.Furthermore,experiment was carried out to verify the feasibility of pitch control methods.The results show that the present collective pitch control and individual pitch control methods can improve the self-starting capacity of SB-VAWT,and the former is much better and its proper operating TSRs ranges from 0.4 to 0.6.展开更多
基金Project (RG039-09AET) supported by University of Malaya, Malaysia
文摘A novel shrouded wind-solar hybrid renewable energy and rain water harvester with an omni-directional-guide-vane(ODGV) for urban high-rise application is introduced.The ODGV surrounds the vertical axis wind turbine(VAWT) and enhances the VAWT performance by increasing the on-coming wind speed and guiding it to an optimum flow angle before it interacts with the rotor blades.An ODGV scaled model was built and tested in the laboratory.The experimental results show that the rotational speed of the VAWT increases by about 2 times.Simulations show that the installation of the ODGV increases the torque output of a single-bladed VAWT by 206% for tip speed ratio of 0.4.The result also reveals that higher positive torque can be achieved when the blade tangential force at all radial positions is optimized.In conclusion,the ODGV improves the power output of a VAWT and this integrated design promotes the installation of wind energy systems in urban areas.
基金Project(HEUCF110707)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(E201216)supported by Heilongjiang Natural Science Fund,China
文摘Wind energy is one of the most promising renewable energy sources, straight-bladed vertical axis wind turbine(S-VAWT) appears to be particularly promising for the shortage of fossil fuel reserves owing to its distinct advantages, but suffers from poor self-starting and low power coefficient. Variable-pitch method was recognized as an attractive solution to performance improvement, thus majority efforts had been devoted into blade pitch angle effect on aerodynamic performance. Taken into account the local flow field of S-VAWT, mathematical model was built to analyze the relationship between power outputs and pitch angle. Numerical simulations on static and dynamic performances of blade were carried out and optimized pitch angle along the rotor were presented. Comparative analyses of fixed pitch and variable-pitch S-VAWT were conducted, and a considerable improvement of the performance was obtained by the optimized blade pitch angle, in particular, a relative increase of the power coefficient by more than 19.3%. It is further demonstrated that the self-starting is greatly improved with the optimized blade pitch angle.
基金supported in part by International Platform for Dryland Research and Education (IPDRE),Tottori University
文摘In this study,wind tunnel experiment was carried out to investigate the self-staring capability for straight-bladed vertical axis wind turbine.The flow visualization also was been performed at the rest of the rotor.The effect of the azimuthal angle of blade position relative to wind direction on the self-starting capability was discussed based on the results of flow visualization.The torque and centripetal force of the rotor when the self-starting behavior starts were roughly calculated with the flow visualization results of the rotor.It is suggested that there exists the condition of wind speed and configuration of the blade position of the rotor at the rest of rotor to the reach to situational rotation number.
文摘The finite element analysis was carried out for a composite vertical axis wind turbine with lift-drag combined starting structures to ensure the structure safety of a vertical axis wind turbine(VAWT).The static and modal analysis of rotor of a composite vertical axis wind turbine was conducted by using ANSYS software.The relevant contour sketch of stress and deformation was obtained.The analysis was made for static structural mechanics,modal analysis of rotor and the total deformation and vibration profile to evaluate the influence on the working capability of the rotor.The analysis results show that the various structure parameters lie in the safety range of structural mechanics in the relative standards.The analysis showing the design safe to operate the rotor of a vertical axis wind turbine.The methods used in this study can be used as a good reference for the structural mechanics′analysis of VAWTs.
基金Project(E201216)supported by Heilongjiang Provincial Natural Science Foundation,China
文摘Collective pitch control and individual pitch control algorithms were present for straight-bladed vertical axis wind turbine to improve the self-starting capacity.Comparative analysis of straight-bladed vertical axis wind turbine(SB-VAWT)with or without pitch control was conducted from the aspects of aerodynamic force,flow structure and power coefficient.The computational fluid dynamics(CFD)prediction results show a significant increase in power coefficient for SB-VAWT with pitch control.According to the aerodynamic forces and total torque coefficient obtained at various tip speed ratios(TSRs),the results indicate that the blade pitch method can increase the power output and decrease the deformation of blade;especially,the total torque coefficient of blade pitch control at TSR 1.5 is about 2.5 times larger than that of fixed pitch case.Furthermore,experiment was carried out to verify the feasibility of pitch control methods.The results show that the present collective pitch control and individual pitch control methods can improve the self-starting capacity of SB-VAWT,and the former is much better and its proper operating TSRs ranges from 0.4 to 0.6.