Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and ...Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and thermo-gravimetric analysis(TGA).The Polythiophene/ WO3 hybrids have higher thermal stability than pure polythiophene,which is beneficial to potential application as chemical sensors.Gas sensing measurements demonstrate that the gas sensor based on the Polythiophene/WO3 hybrids has high response and good selectivity for de- tecting NO2 of ppm level at low temperature.Both the operating temperature and PTP contents have an influence on the response of PTP/WO3 hybrids to NO2.The 10 wt%PTP/WO3 hybrid showed the highest response at low operating temperature of 70-C.It is expected that the PTP/WO3 hybrids can be potentially used as gas sensor material for detecting the low concentration of NO2 at low temperature.展开更多
Microwave heterodyne detection can be used to measure the temperature and strain distribution along a fiber with high accuracy in a Brillouin optical time domain reflectometry (BOTDR) system. This method involves si...Microwave heterodyne detection can be used to measure the temperature and strain distribution along a fiber with high accuracy in a Brillouin optical time domain reflectometry (BOTDR) system. This method involves simultaneous measurement of Brillouin scattering and Rayleigh scattering in fiber, and scanning of Brillouin spectrum to obtain the desired information. This paper presents a simultaneous measurement system of temperature and strain based on microwave detection and analyzed the system performances such as measurement accuracy, dynamic range, and spatial resolution theoretically. The analysis shows that the system can achieve a temperature resolution of 1°C and a strain resolution of 100 μs.展开更多
The reasons why thermal imaging systems consume power are analyzed,and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the re...The reasons why thermal imaging systems consume power are analyzed,and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the response performance of α-Si microbolometer detector and its operating temperature is studied by means of formulas of microbolometer detector's noise equivalent temperature difference(NETD) and detectivity. Numerical analysis based on true parameters demonstrates that the detectivity decreases slightly and NETD increases slightly when operating temperature rises,which indicates that α-Si microbolometer detector has approximately uniform response in a wide operating temperature range. According to these analyses,a thermal imaging system operating at multiple temperatures is designed. The power of thermoelectric stabilizer(TEC) is less than 350 mW and NETD is less than 120 mK in the ambient temperature range of-40 ℃-60 ℃,which shows that this system not only outputs high-quality images but consumes low power.展开更多
Accurate decay detection and health assessment of trees at low temperatures is an important issue for forest management and ecology in cold areas.Low temperature ice formation on tree health assessment is unknown.Beca...Accurate decay detection and health assessment of trees at low temperatures is an important issue for forest management and ecology in cold areas.Low temperature ice formation on tree health assessment is unknown.Because electric resistance tomography and stress wave tomography are two widely used methods for the detection of tree decay,this study investigated the effect of ice content on trunk electrical resistance and stress wave velocity to improve tree health assessment accuracy.Moisture content,trunk electrical resistance and stress wave velocity using time domain reflectometry were carried out on Larix gmelinii and Populus simonii.Ice content is based on moisture content data.The ice content of both species showed a trend of increasing and then decreasing.This was opposite with ambient temperatures.With the decrease of temperatures,daily average ice content increased,but the range narrowed gradually and both electrical resistance and stress wave velocity increased.Both increased rapidly near 0℃,mainly caused by ice formation(phase change and freezing of free water)in live trees.In addition,both are positively correlated with ice content.The results suggest that ice content should be considered for improving the accuracy of tree decay detection and health evaluation using electric resistance tomography and stress wave velocity methods under low temperatures.展开更多
The miniaturized broadband detection module can be embedded into the microwave application system such as the front end of the transmitter to detect the power or other parameters in real time.It is highly prospective ...The miniaturized broadband detection module can be embedded into the microwave application system such as the front end of the transmitter to detect the power or other parameters in real time.It is highly prospective in military and scientific research.In this paper,a broadband power detection module operating at 26.5 GHz-40.0 GHz is designed by using low-barrier Schottky diode as the detector and a comparator for threshold output.This module can dynamically detect the power range between-10 dBm and 10 dBm with the detection accuracy of 0.1 dB.Further,the temperature compensation circuit is also applied to improve the measurement error.As a result,the resulted error low to±1 dB in the temperature range of -55℃ to +85℃ is achieved.The designed module is encapsulated by a Kovar alloy with a small volume of 9 mm×6 mm×3 mm.This endows the designed module the advantages of small size,easy integration,and low cost,and even it is applicable to high-reliability environments such as satellites.展开更多
基金financially supported by the National Natural Science Foundation of China(No.20871071)the Science and Technology Commission Foundation of Tianjin(No.09JCYBJC03600 and 10JCYBJC03900)
文摘Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and thermo-gravimetric analysis(TGA).The Polythiophene/ WO3 hybrids have higher thermal stability than pure polythiophene,which is beneficial to potential application as chemical sensors.Gas sensing measurements demonstrate that the gas sensor based on the Polythiophene/WO3 hybrids has high response and good selectivity for de- tecting NO2 of ppm level at low temperature.Both the operating temperature and PTP contents have an influence on the response of PTP/WO3 hybrids to NO2.The 10 wt%PTP/WO3 hybrid showed the highest response at low operating temperature of 70-C.It is expected that the PTP/WO3 hybrids can be potentially used as gas sensor material for detecting the low concentration of NO2 at low temperature.
基金supported by the National 863 Program under Grant No. 2006AA09Z141the Scientific Research Foundation for the Returned Overseas Chinese Scholars (Ministry of Education of China) under Grant No. 2005383the Scientific Research Foundation for the Returned Overseas Scholars (North China Electric Power University) under Grant No. 20041401
文摘Microwave heterodyne detection can be used to measure the temperature and strain distribution along a fiber with high accuracy in a Brillouin optical time domain reflectometry (BOTDR) system. This method involves simultaneous measurement of Brillouin scattering and Rayleigh scattering in fiber, and scanning of Brillouin spectrum to obtain the desired information. This paper presents a simultaneous measurement system of temperature and strain based on microwave detection and analyzed the system performances such as measurement accuracy, dynamic range, and spatial resolution theoretically. The analysis shows that the system can achieve a temperature resolution of 1°C and a strain resolution of 100 μs.
文摘The reasons why thermal imaging systems consume power are analyzed,and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the response performance of α-Si microbolometer detector and its operating temperature is studied by means of formulas of microbolometer detector's noise equivalent temperature difference(NETD) and detectivity. Numerical analysis based on true parameters demonstrates that the detectivity decreases slightly and NETD increases slightly when operating temperature rises,which indicates that α-Si microbolometer detector has approximately uniform response in a wide operating temperature range. According to these analyses,a thermal imaging system operating at multiple temperatures is designed. The power of thermoelectric stabilizer(TEC) is less than 350 mW and NETD is less than 120 mK in the ambient temperature range of-40 ℃-60 ℃,which shows that this system not only outputs high-quality images but consumes low power.
基金supported by the National Natural Science Foundation of China (Grant No.31870537)Innovation Foundation for Doctoral Program of Forestry Engineering of Northeast Forestry University (Grant No.LYGC202115)National Key Research and Development Program of China (Grant No.2021YFD2201205)。
文摘Accurate decay detection and health assessment of trees at low temperatures is an important issue for forest management and ecology in cold areas.Low temperature ice formation on tree health assessment is unknown.Because electric resistance tomography and stress wave tomography are two widely used methods for the detection of tree decay,this study investigated the effect of ice content on trunk electrical resistance and stress wave velocity to improve tree health assessment accuracy.Moisture content,trunk electrical resistance and stress wave velocity using time domain reflectometry were carried out on Larix gmelinii and Populus simonii.Ice content is based on moisture content data.The ice content of both species showed a trend of increasing and then decreasing.This was opposite with ambient temperatures.With the decrease of temperatures,daily average ice content increased,but the range narrowed gradually and both electrical resistance and stress wave velocity increased.Both increased rapidly near 0℃,mainly caused by ice formation(phase change and freezing of free water)in live trees.In addition,both are positively correlated with ice content.The results suggest that ice content should be considered for improving the accuracy of tree decay detection and health evaluation using electric resistance tomography and stress wave velocity methods under low temperatures.
基金financially supported by the Sichuan Provincial Natural Science Foundation Project under Grant No.2023NSFSC0048.
文摘The miniaturized broadband detection module can be embedded into the microwave application system such as the front end of the transmitter to detect the power or other parameters in real time.It is highly prospective in military and scientific research.In this paper,a broadband power detection module operating at 26.5 GHz-40.0 GHz is designed by using low-barrier Schottky diode as the detector and a comparator for threshold output.This module can dynamically detect the power range between-10 dBm and 10 dBm with the detection accuracy of 0.1 dB.Further,the temperature compensation circuit is also applied to improve the measurement error.As a result,the resulted error low to±1 dB in the temperature range of -55℃ to +85℃ is achieved.The designed module is encapsulated by a Kovar alloy with a small volume of 9 mm×6 mm×3 mm.This endows the designed module the advantages of small size,easy integration,and low cost,and even it is applicable to high-reliability environments such as satellites.