A novel cooling system with cooling channels is proposed for the stator of 3MW wind-driven generator.An experimental platform is built to investigate the performance of the cooling system with different loads.At30%,50...A novel cooling system with cooling channels is proposed for the stator of 3MW wind-driven generator.An experimental platform is built to investigate the performance of the cooling system with different loads.At30%,50% or 80% generator loads,the temperatures meet the design requirement.However,it is a little over the requirement at 100%load,duo to experimental errors and some unknown thermal resistances.In the test at 100%load,the developing trends of the parameters of these two generators are similar and only minor differences occurs when they reach steady state our work can be benefit for the design and improvement of MW wind-driven generator cooling solutions.展开更多
As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power syst...As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model.展开更多
文摘A novel cooling system with cooling channels is proposed for the stator of 3MW wind-driven generator.An experimental platform is built to investigate the performance of the cooling system with different loads.At30%,50% or 80% generator loads,the temperatures meet the design requirement.However,it is a little over the requirement at 100%load,duo to experimental errors and some unknown thermal resistances.In the test at 100%load,the developing trends of the parameters of these two generators are similar and only minor differences occurs when they reach steady state our work can be benefit for the design and improvement of MW wind-driven generator cooling solutions.
文摘As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model.