Surface blood compatibility of ion beam and plasma treatment on polyetherurethane has been studied.O^(+)implantation was performed at 80keV with various doses.O_(2) plasma treatment was carried out at 100 W with vario...Surface blood compatibility of ion beam and plasma treatment on polyetherurethane has been studied.O^(+)implantation was performed at 80keV with various doses.O_(2) plasma treatment was carried out at 100 W with various exposure times.The results indicated that surface anticogulability was enhanced in varying degrees and anticalcific behavior was not decreased.X-ray photoelectron spectroscopy and electron spin resonance analysis showed that the two methods not only broke some chemical bonds,but also produced some new N-O and C-O bonds and radicals in the surface,which affected the surface biomedical behavior.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No.19305006the Natural Science Foundation of Tianjinby the Ion Beam Laboratory,Shanghai Institute of Metallurgy,Chinese Academy of Sciences.
文摘Surface blood compatibility of ion beam and plasma treatment on polyetherurethane has been studied.O^(+)implantation was performed at 80keV with various doses.O_(2) plasma treatment was carried out at 100 W with various exposure times.The results indicated that surface anticogulability was enhanced in varying degrees and anticalcific behavior was not decreased.X-ray photoelectron spectroscopy and electron spin resonance analysis showed that the two methods not only broke some chemical bonds,but also produced some new N-O and C-O bonds and radicals in the surface,which affected the surface biomedical behavior.